Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface of an auto switch mounting bracket contact the cylinder tube firmly. (Use a hexagon wrench.) 2. Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. 3.
If there is no buffer mechanism, an excessive impact force is generated. As a result, the tensile compression force of the floating joint may exceed its maximum level.
Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.
Be sure to connect the load to the plate section with the lock in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. Sizes 20 through 32 have a built-in holding function for the unlocked state, allowing the unlocked condition to be maintained even without an air supply.
Do not install in Zone 0 (as defined in IEC 60079-101:2008) or Zone 20 (as defined in IEC 60079-10-2:2009) Zone 0 area classification: An area in which an explosive gas atmosphere is present continuously or for long periods or frequently.
Be sure to connect the load to the plate section with the lock in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. Sizes 20 through 32 have a built-in holding function for the unlocked state, allowing the unlocked condition to be maintained even without an air supply.
The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.
41.5 48 56 80 83 86.5 D-F7lWV 5 14 18 40 45 42.5 39.5 46 54 78 81 40.5 D-A9ll 3 12 16 38 43 81.5 46 52.5 60.5 84.5 87.5 91 D-F7NT 9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16
Use an exclusive crimping tool for crimping. (Please contact SMC for the dedicated crimping tools.)
[Tips]
(Assuming approximately 30% dispersion) There may be the case to change substantially depending on an ambient environment.
(Assuming approximately 30% dispersion) There may be the case to change substantially depending on an ambient environment.
H G I J K L A B C D E F M R +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 9 9 16 16 +0.027 0 +0.027 0 +0.027 0 +0.027 0 36 38 55 55 16 18 22 22 9 9 12 15 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 16 30 30 36 44 M4 10 10 13 13 10
Compressed air can be dangerous if an operator is unfamiliar with it.
[When an intermediate valve only is exhausted] Indicate the arrangement of the individual EXH block assembly and EXH blocking disk on a manifold specification sheet. (The applicable manifold model is SS5Y-60-B.)
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
Connect the remote control cable and the switch to the connector for the contact input/output, supplied as an accessory. Then, mount the ferrite core (3 turn) supplied as an accessory. (See below) (This is an example of wiring. Refer to the Operation Manual for communication for details.)
Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 11 Series VCW 2 Port Solenoid Valve for Fluid Control/Precautions 1 Be sure to read before handling. Precautions on Design Selection Warning Warning 1. Cannot be used as an emergency shutoff valve, etc.
Be careful to the supply pressure and kinetic energy when performing an intermediate stop. Fine end stroke adjustment is considered as an intermediate stop, so the considerations for an intermediate stop must be observed when making any fine adjustments. When stopping the external slider in an intermediate position with an external stopper.