K 6 9 M 45.5 50.5 N 69 76 VVXA31 VVXA32 17-3-108
Load mass kg Load mass kg m s m s Type of impact s m 1 2 m2 Kinetic energy E1 Thrust energy E2 Fs Fs + mgs Fs mgs Absorbed energy E E1 + E2 Symbols : Speed of impacting object (m/s) m: Mass of impacting object (kg) F: Cylinder thrust (N) g: Gravitational acceleration (9.8 m/s2) s: Shock absorber stroke (m) Note) The speed of the impacting object is measured at the time of impact with
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ There are other applicable auto switches than listed above. For details, refer to page 775. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785. D-A9/M9/M9W/M9AL auto switches are shipped together (not assembled).
Nil (Example) A73C 3 m L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN Solid state switches marked with are produced upon receipt of order.
E F G H1 H2 J K L M N Model LVH20m LVH30m LVH40m 30 30 52 44 11 79 10 72.5 74 4 20 37 3.5 27 36 47 81.5 56 16.5 106 19 111 113 7.5 34 46 5.5 37.5 46 60 100 68 22.5 131 20.5 139 143 8 42 57 5.5 50 483 Series LVH Dimensions/Threaded Type N Body material: PPS Body material: Stainless steel N G A G A D L Non-locking type Locking type 60 K 4 x M Non-locking type Locking type (H1) (H2) C 60 A B
Nil (Example) A73C 3 m L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN Solid state switches marked with are produced upon receipt of order.
-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 Sensor (Breathing port) R VXA 2-Q VN PB LVC G H PA C LVA SMC A B LVH N E LVD J B LVQ (F) LQ LVN TI/ TIL PA (mm) Dimensions PAX A B C D E F G H J K L M M5 x 0.8 R N Q Model LVC2 LVC3 LVC4 LVC5 LVC6 30 30 54.5 44 11 79 28.5 13 4 20 37 3.5 23.5 M3 x 0.5 PB 36 47 79 56 16.5 106 43 17.5 7.5 34 46 5.5 39 46 60 96 68 22 131 55
Install an air filter Install an air filter of 5 m or smaller filtration on upstream side. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.
Environment at an altitude of 1000 meters or higher Heat radiation and withstand voltage will decrease. Contact SMC for details. (2) Do not use in an environment where the product is directly exposed to liquid, such as cutting oils.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
3 Only for use with M(D)LUB25 Release piston seal NBR M(D)LUB40, 50 Lead-bronze casting !
Do not install in Zone 0 (as defined in IEC 60079-101:2008) or Zone 20 (as defined in IEC 60079-10-2:2009) Zone 0 area classification: An area in which an explosive gas atmosphere is present continuously or for long periods or frequently.
When disassembling a cylinder with a bore of 20 to 40, use a vise or the like to hold the wrench flats portion of the tube cover or the rod cover on one side, while placing a wrench or an adjustable wrench on the other side to loosen and remove the cover. To replace, tighten it an additional 28 from the installed position.
PLe " ~,I I' : II jNo 2OOVm 'M A64 I-I. 24 V 12 V A33 1 '~ '" V. 200 VI--_ --+-=--t-t I-t I-j-1 ~~~! c--t-1=Relay. 'W ~~~ -=L= I,PLC I ! I. ' ~ Lead wire length symbols: 0.5 m . Nil (Example) M9NW 1 m . M (Example) M9NWM 3 m . L (Example) M9NWL 5 m . .
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are applicable auto switches other than listed, refer to page 23 for details. For details about auto switches with pre-wired connector, refer to Best Pneumatics No. 2. D-A9, M9, M9W, M9AL are shipped together (but not assembled).
21.4 24.9 M L Q A D D O N M M Note 1) D is maximum diameter.
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]