Switch Mounting Position D-F5, D-F5W D-J5, D-J59W D-F59F, D-F5BAL D-Z7, D-Y59, D-Y7BAL D-Z80, D-Y69, D-Y7W(V) D-Y7P(V) D-A5 D-A6 D-A59W D-F5NTL D-A3, D-G39 D-A44, D-K39 D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 0 10.5 1.5 14 9.5 22 4.5 17 2 14.5 0 10.5 1 13.5 40 0 21.5 1.5 25 9.5 33 4.5 28 2 25.5 0 21.5 1 24.5 50 0 23 2 26.5 10 34.5 5 29.5 2.5 27 0 23 1.5 26 63 0 28 2 31.5 10
A B A B A B A B A B A B A B A B A B Bore size 40 50 63 80 100 6 4 3.5 1.5 3 1 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 3.5 1.5 3 1 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 5.5 4 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 9 7 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 10.5 9 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 Note 1) Adjust
CAT.ES70-26 B Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam Reduced power consumption (DC specification) Reduced Reduced power consumption power consumption (DC specification) (DC specification) 6 6 W 4. 4.5 W 6 W 4.5 W 8 8 W 7 W 8 W 7 W 11.5 1.5 W 10. 0.5 W 11.5 W 10.5 W Series VX31/32/33 3 VX3 New New 3 Reduced power Reduced power consumption consumption (DC specification
q q 1 unit q w Set value can be copied up to 10 units.
B B-6 Orange 9 B A-6 Black 8 3 Electric actuator side Driver side (30.7) 10 - (3) Actuator cable for with lock and sensor (5m or less) Cable color Terminal no. Signal Terminal no.
Applicable air dryer Capacity Type Inlet voltage Outlet voltage A B C D E F Weight IDF-TR500-3 IDF1E-10 to 8E-10 IDU3E-10, 4E-10, 8E-10 500 VA 380, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 100 VAC (50 Hz) 110 VAC (60 Hz) 15 kg IDF-TR1000-3 IDF11E-10, 15E1-10 IDU6E-10, 11E-10, 15E1-10 1 kVA Singlephase Singleturn 230 207 190 210 160 9 IDF-TR500-4 IDF1E-10 to 8E-10 IDU3E-10, 4E-10, 8E-10
Band mounting A B Built-in magnet MB Nil D None Applicable auto switches and bands are shown on pages 6-10-45 to 6-10-46.
151 to 200 50 50 201 to 300 75 75 301 to 400 100 100 401 to 500 125 125 1 to 50 57 64 51 to 100 70 77 101 to 150 82 89 151 to 200 201 to 300 120 127 301 to 400 145 152 401 to 500 170 177 32 40 95 102 6-10-9 10 Series C76 Dimensions with Mounting Bracket [First angle projection] Double acting: Single rod Rod foot (Flange), Rod and head foot: C76F32A B, C76F40A B LT W TF UR NH AU XS TR 12-
Note that frequencies 2446-2468 [MHz] correspond to (1) W-LAN Channel: CH.10 above.
W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
When using a regenerative resistor, set the capacity (W) of the regenerative resistor. 3. The upper limit is the maximum output capacity (W) of the DRIVER. 10-23 10 List of Parameters (contd) Parameter Name Setting Units Factory When Classification Reference Size No.
MGC MGF CY1 q B MY1 Normally ON w * Adjust the switch position according to load and speed.
Example: Set 20 W (100 W 20%) for the 100-W external regenerative resistors with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2. When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used.
Metric sizes 4 8 10 16 22 Millimeter 06 10 12 19 25 6 10 12 19 25 6 10 12 19 25 Inch Valve type Type 1/4 Symbol 3/8 1/2 3/4 1 Basic type N.C. N.C. PA PB PA Inch sizes 07 11 13 19 25 1/4 3/8 1/2 3/4 1 N.O. B A A B A B PB N.C. N.O. Double Double acting N.O. Double acting acting With flow rate adjustment PA PA A B N.C. A B N.C. N.C. With bypass PA PA N.C. A B A B Double acting PB N.C.
D-Z7m D-Z8m D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NT D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3 0 0 2.5 2.5 4.5 4.5 2 2 50 10 9 6 5 6.5 5.5 11.5 10.5 0 0 4 3 0 0 3.5 2.5 5.5 4.5 3 2 63 10
B 22 46 Code q Code w Ejector exhaust type Weight Standard accessory Codes q and w are corresponding to the suffixes in How to Order to indicate the exhaust method.
NA-M5 x 0.8 thread depth 6.5 10 M 21 KA Bottom view of MXQ6-30 10 5.5 21 K 13 35 45 10 5.5 33.7 0.3 5.5 37 Z ZZ (NN 1) x H G H 21 9 21 9 A B 10.5 10.5 5.1 5.1 9.5 9.5 24 5H9 depth 5 +0.030 0 1 NN-M6 x 1 thread depth 12 6 B A 5H9 depth 5 +0.030 0 HA GA Section AA Section BB (mm) Model F 38 38 48 58 40 46 44 44 N 4 4 4 4 6 6 8 10 G 18 18 19 19 21 36 17 H 39 39 48 58 52 44 44 NN 2 2 2 2