SMC Corporation of America
Elite Part Number Search
Search Results "D-A93L"

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 430, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa

Magnet: Built-in, Mounting: Rear Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Rear Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 900mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 900mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC4 (w/Heavey Duty Scraper)

Magnet: D (Built-in), Mounting: L (Axial Foot), Cushion: A (Non-lube Air Cushion), Bore Size: 40mm, Port Thread: Rc, Stroke: 250mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: N (Non-lube Rubber Bumper), Bore Size: 40mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: D (Built-in), Mounting: L (Axial Foot), Cushion: N (Non-lube Rubber Bumper), Bore Size: 40mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: D (Built-in), Mounting: B (Basic Style), Cushion: A (Non-lube Air Cushion), Bore Size: 32mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: D (Built-in), Mounting: B (Basic Style), Cushion: A (Non-lube Air Cushion), Bore Size: 40mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: D (Built-in), Mounting: B (Basic Style), Cushion: N (Non-lube Rubber Bumper), Bore Size: 25mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: D (Built-in), Mounting: L (Axial Foot), Cushion: A (Non-lube Air Cushion), Bore Size: 25mm, Port Thread: Rc, Stroke: 250mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)

Magnet: Built-in, Mounting: Axial Foot, Cushion: Non-lube Air Cushion, Bore Size: 40mm, Port Thread: Rc, Stroke: 250mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket

Magnet: Built-in, Mounting: Front Flange, Cushion: Non-lube Rubber Bumper, Bore Size: 40mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket

Magnet: Built-in, Mounting: Axial Foot, Cushion: Non-lube Rubber Bumper, Bore Size: 40mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket

Magnet: Built-in, Mounting: Basic Style, Cushion: Non-lube Air Cushion, Bore Size: 32mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket