L 3 m Connector Nil w/ connector Stroke(mm) Made To Order Fluoro rubber packing (Ex.) 2-2-2 Applicable Auto-Switch Models Z w/o connector 25, 50, 75, 100 Mark Auto-Switch Model Mark Auto-Switch Model Mark Auto-Switch Model A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW 2-color D-M9PW A96 Reed D-A96 M9B Solid State D-M9B M9BW Indication Solid State D-M9BW A90V Auto-Switch D-A90V
Name Size Material 1 Valve Rc3/4 Stainless steel 2 Y-strainer (100m) Rc3/4 Stainless steel 3 Valve Rc1/2 Stainless steel 4 Y-strainer (5m) Rc1/2 Stainless steel 3.3 Procedure for Installation HRZD Series 3-14 HRX-OM-M005 Chapter 4 Product Startup and Shutdown Chapter 4 Product Startup and Shutdown Only personnel, who have adequate knowledge of and experience with not only this product but
Select an air filter with a filtration size of 5m or smaller. 2. Install an aftercooler, air dryer or drain catch before the filter. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment. 3. Discharge condensates regularly.
The filtration degree should 5m or less. Install an air dryer, after cooler, etc. Air that includes excessive condensate may cause malfunction of valves and of other pneumatic equipment. To prevent this, install an air dryer, after cooler, etc. 3. Use the product within the specified range of fluid and ambient temperature.
(HRZ00*-L2) Pressure falls within the 0.5 to 2.0Mpa(75 to 290PSI) range.(All other Models) Refrigerant pressure Reading of the refrigerant pressure gauge Discharge pressure of circulating fluid Confirm the reading on the LCD screen Reading should not have deviated much from last inspection.
wire(NPN) 5V, 12V IC Grommet 3 wire(PNP) 2 wire 12V Connector 5V, 12V 12V 3 wire(NPN) 2 wire IC Terminal conduit Yes Relay PLC 24V 3 wire(NPN) 5V, 12V IC Diagnostic indicator (2color) 3 wire(PNP) 12V 2 wire Water resistant (2 color) With timer Grommet 3 wire(NPN) 5V, 12V IC Diagnostic output (2 color) 4 wire (NPN) Latch with diagnostic output (2 color) * Lead wire length 0.5m : 3m : L 5m
The filtration degree should be 5m or finer. 2. Install an after-cooler, air dryer or water separator, etc. Air that includes excessive drainage may cause malfunction of valves and other pneumatic equipment. To prevent this, install an after-cooler, air dryer or water separator, etc. 3. Use the product within the specified range of fluid and ambient temperatures.
drain Filtration rating 5m Note 1) ISO8573-1:2010 [6:8:4] Compressed air quality class 3 Drain capacity 3 25 cm 3 45 cm 8 cm Bowl material Polycarbonate Bowl guard Standard (Polycarbonate) Semi-standard (Steel) Weight 0.09 kg 0.17 kg 0.35 kg 0.39 kg 0.85 kg 0.92 kg Note 1) Based on ISO8573-1:2010 Compressed air Part1: Contaminants and purity classes.
With sleeve lock mechanism (Except KK2) KK2 KK346 For details on this product, refer to page 15-2-75. For details on this product, refer to page 15-2-86.
A filtration degree of 5m or less should be selected. 2. Install an air dryer, after cooler, etc. Air that includes excessive condensate may cause malfunction of valves and other pneumatic equipment. To prevent this, install an air dryer or after cooler etc.. 3. If excessive carbon dust is generated, eliminate it by installing mist separators at the upstream side of valves.
Unit/Specifications Air filter (w/auto-drain, w/manual drain) 5m Filtration Regulator 0.05 to 0.85MPa Set press.
Product part number Auto drain number Normally closed Normally open HAW2-04C/D AD402-04C-6-A AD402-04D-6-A HAW7-06D AD402-04D-6-A HAW22/37-14D AD600-06 HAW55/75-20D AD600-06 HAW110-30D AD600-10 2) The drain piping, if conducted, should have an inside diameter of at least 10mm and a maximum length of 5m.
Note 3: Air flow capacity converted by the compressor intake condition [32C, Atmospheric pressure, and 75% relative humidity] Note 4: Do not use this product with continuous voltage fluctuations. Note 5: These values are reference values under rated conditions and are not guaranteed. Do not use these values for the thermal set values, etc.
The drain piping should have an internal diameter of 8mm or more and be 5m or less in length. Make sure that it does not go upwards and it is not bent. The outlet end of the tube is released to atmosphere, and lets the drain flow through the tube. Ensure that the ball valve is opened. Refer to 7.3 Dimensions of the Chapter 7.
Note 2) Air flow capacity converted by the compressor intake condition [32oC, Atmospheric pressure, and 75% relative humidity] Note 3) The operating range does not guarantee use with normal air flow capacity.
Note 3: Air flow capacity converted by the compressor intake condition [32C, atmospheric pressure, and 75% relative humidity]. Note 4: Do not use this product with continuous voltage fluctuations. Note 5: These values are reference values under rated conditions and are not guaranteed. Do not use these values for the thermal set values, etc.
1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 DC L,M L,M L,M L,M
setting 40 System setting 42 Frequency channel select function (F.C.S.) 45 Event 47 Wireless 49 Pairing and Unpairing Procedures 51 Pairing Procedure 51 Unpairing Procedure 56 Mounting and Installation of Units 58 EXW1-BMJ*, EXW1-RD* 58 Troubleshooting 61 Technical Information 72 I/O Map 72 I/O Mapping 74 Diagnostics Mapping 74 I/O Mapping Order When EX600-WSV* Is Paired 75
L 5m ... Z None ... N (Example) C80CZ, C80CN Solid state auto switches marked "" are produced upon receipt of order. You do not need to specify "N" (i.e., without lead wire) for D-A3A, D-A44A, D-G39A, and D-K39A. This is the only standard specification automatically available for these models.