SMC Corporation of America
Elite Part Number Search
Search Results "CNA2B80-900-D"

(N.O. type/N.C. type can be changed.) 3 Do not connect wiring. 1 14 25 13 D-sub 25-pin female (socket) type 8 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Communication Functions Serial Communication The following operations can be performed by the serial communication RS-232C/RS-485.

bottom, (right) Note) Refer to the catalog for Stroke, Auto switch and Number of auto switches. 3 positions Names and Functions of Controller 11 Example of Internal Circuit and Wiring 12 Setting 15 Operation Characteristics 20 Specifications 21 10 Names and Functions of Controller (3 positions) Controller detail General 3 positions 5 positions General A 1 2 5 7 State of indicator light D

equipped as standard.) sPage 177 sPage 180 With fluid fill port 156 A Thermo-chiller Inverter Type HRSH Series Circulating Fluid Temperature Controller Circuit diagram HRSHl-W-l (Water-cooled refrigeration) HRSHl-A-l (Air-cooled refrigeration) HRS Ventilation DC inverter fan HRS 090 Water regulating valve Air release valve for facility water discharge HRS 100/150 WPR Facility water outlet D

Grounding should be to a D-class ground. (Ground resistance of 100 or less.) -13- 3. Grounding should be performed near the actuator to shorten the grounding distance. 4. The cross-sectional area of this wire shall be a minimum of 2 mm2. 5. Avoid common grounding with other devices.

Series HRS100/150 CAT.NAS40-62B R410A as refrigerant Thermo-chiller Standard Type Series HRS100/150 Circulating Fluid Temperature Controller Triple controller Fan Air-cooled condenser fan control Cooling valve Heating valve Circuit diagram Ventilation Cooling valve control Fan Facility water outlet Temperature sensor (Heat exchanger inlet) Water-cooled condenser Dryer Air-cooled condenser D

See specification table for refrigerant used in the product. 6-3 Dimensions IDFB22E / 37E UNIT : inch [mm] AIR OUTLET AIR INLET A PORT SIZE PORT SIZE B E D G AUTO DRAIN WITH LAMP SWITCH THERMOMETER EVAPORATION BALL VALVE VENTILATION VENTILATION F C BLOCK TERMINAL DRAIN TUBE LENGTH35.4[900]) (O.D.3/8 J N M H K L P 911])OPPOSITION 0.4[ WIRE ELECTRICAL ENTRY [4xDIA.13] 4xDIA.0.5 Model Port

E F C (35.4[900]) J M N P L K H 4x0..5 (0.4[9~11mm] [4x13] [IDFB22E-11*(L=2800)] Unitinch [mm] A B C D E F G H J K L M N P 30.5 23.6 IDFB22E 1 [775] [600] 3.3 11.4 24.5 5.3 15.9 27.5 3.7 1.8 1 0.5 12.4 13.4 [290] [623] [134] [405] [698] [93] [46] [25] [13] [314] [85] [340] 26.8 33.7 IDFB37E 1/2 [855] [680] R IDFB55E/75E Q A B H G E D F C (0.4 (39.4[1000]) J L K M N P 4x0..5 [4x13]

Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]

-phase 200 VAC 3-phase 400 VAC [mm] [mm] 93 Environmental friendly R410A as refrigerant Thermo-chiller Standard Type HRS100/150 Series Circulating Fluid Temperature Controller Fan Triple controller Air-cooled condenser fan control Cooling valve Heating valve Circuit diagram Ventilation Cooling valve control Fan Facility water outlet Dryer Air-cooled condenser D

Inverter pump Triple inverter HRZD HRW 0.6 kW 1.8 kW Water-cooled refrigeration Air-cooled refrigeration HECR 377 [mm] 970 HEC 2.4 kW HEB Triple inverter HRSH090 HED *1 Under the conditions shown on page 128 HEA Cooling capacity 9.5 kW IDH 1080 0.1C Temperature stability (when a load is stable) Set temperature range 5C to 40C W 377 x H 1080 x D 970 mm Compact, Space-saving Low-noise design

Main sealing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Main sealing D side sealing A side sealing A seal is formed when the tubing is inserted, with its insert bushing, and its compression against the internal nut.

Suite D Poway, CA 92064 TEL: (858) 679-190s FAX: (858) 679-1904 ARGENTINA SMC Argentina S.A. CHILE SMC Pneumatics (Chite) Ltda.

1200 Installation distance [mm] mm At maximum air flow (air flow scale: 4) 300 mm 300 0 4s 6s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm At minimum air flow (air flow scale: 1) 300 mm 300 6s 0 4s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm 18 - Doc. no.

L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max. Model Port size Model Port size 120 150 AS800 AS900 1 1 , 2 74 93 204 262 192 250 80 94 AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 15-9-33

Touching an emitter when it is electrified may result in electric shock or other accidents. d) Avoid using in a place in the presence of corrosive or explosive gas or where there is a volatile combustible. 3.

G Note) Float switch specifications Voltage Max. cut off capacity Max. cut off current Contact Level indication 200 VAC, 200 VDC 12 VA AC, 10 W DC 0.6 A AC, 0.5 A DC 1a, 1b Bottom limit indication PPA How to Order AL ALB 900 0 0 10 S1 Float switch (Option) Booster lube Operation control signal Nil S1 S2 900 2 inch standard None 1b (Without oil ON) 1a (Without oil OFF) Body size 0 1 2 4 5

After removing the cause of the alarm or warning, the alarm or warning can be deactivated in any of the methods marked in the alarm / warning deactivation column. "6" of the figure, "B" of the alphabet, and "D" are displayed as follows. 6 B D 7.1 Alarms List This section provides list of alarms.

F C D E Setting the Indicator Needles Move the indicator needles with your fingers. If it is done with a small screw driver, etc., take care not to bend the indicator needles or scratch the gauge dial. There are 2 green indicator needles, to be set at the upper and lower limits of the pressure range.

Symbol fl:] w 8$ Flow Characteristics NAN200 900 Specifications 35 70 125 3s0 200 r7s0 An Flow (SCFMI Mar opetating pressu|e-145PSl(t0 2kg lcIrf) Nois reduction-30d B or more Operating tenperature range-40 1 40"F (5 ' 60 "C) Noise Level Model Model Port size (NPT) Eftectlve oririce mm2 (Cv) Wbight rbs.