SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B40-30DMZ-L-A93"

φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Mounting

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number

Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 16mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads:

Magnet: Built-in, Mounting: Double Clevis, Type: Standard, Bore Size: 12mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Mounting

30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002

Cylinder with Lock Double Acting, Single Rod 125, 140, 160, 180, 200, 250 Series CLS How to Order CLS L D 125 100 M9B M9B With Auto Switch CDLS M9BW L D 125 100 With auto switch (Built-in magnet) Cylinder unit auto switch Port thread type Nil TN TF Lock unit auto switch Nil Without auto switch Mounting style B L F G Rc NPT G Nil Without auto switch Select applicable auto switches from the

Nil (Example) A93 3m . L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.

Lead wire length (m) Load voltage Direct mounting Rail mounting Indicator light Applicable load Special function Type Electrical entry Wiring (output) 12 to 50 32 to 50 None (N) 0.5 (Nil) 3 (L) 5 (Z) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equiv.)

Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 11 12 Vacuum suction type Relief type (with specially treated sliding parts) CXSJM, CXSJL CXSJL CXS 6 50 J 11 L M9B S 21 CXS L J 6 50 M9B S Number of auto switches 2 pcs. 1 pc. n pcs.

Air Cylinder Short Type Standard: Double Acting, Single Rod CG3 Series 20, 25, 32, 40, 50, 63, 80, 100 RoHS CJ1 How to Order CJP CJ2 L 25 CG3 100 N JCM CDG3 L 100 M9BW N 25 C With auto switch CM2 With auto switch (Built-in magnet) CM3 Made to Order For details, refer to page 366.

Round Type Hydraulic Cylinder 20, 25, 32, 40 CHM Series 3.5 MPa How to Order CHM 25 100 L CHDM 25 100 M9BW L Auto switch mounting bracket Note) C With Auto Switch With auto switch (built-in magnet) Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.)

L Ball bushing bearing 3 3 pcs. Nil Without auto switch (Built-in magnet) Bore size 4 4 pcs. 63 63 mm For the applicable auto switch model, refer to the table below.

Consult with SMC regarding water resistant types with the above model numbers. 21 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. For D-P3DWA, 32 to 63 are available.

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

IC Grommet Yes Reed circuit 100V A93V*2 A93 Relay, 2-wire 24V 12V PLC No 100V or less A90V A90 IC circuit *1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. *2 1m type lead wire is only applicable to D-A93.