(Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, SZ BUILT IN FITTING LESS THAN 1/4), VALVE, SJ2000/SJ3000/SZ3000, UF, SZ BUILT IN FITTING LESS THAN 1/4), 0.22046 lb
(Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, PLUG-IN, VALVE, SJ2000/SJ3000/SZ3000, UF, SZ BUILT IN FITTING 1/4), .26301 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm2 (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm2 (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less
(Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, SZ BODY PORT (M5, NON-US STD), VALVE, SJ2000/SJ3000/SZ3000, BG, SZ BODY PORT (M5, NON-US STD), 0.43273 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, NON PLUG IN, 3-PORT, 4/5 PORT SOLENOID VALVE, G92, 84.00000 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, 2POS/DBL, NON PLUG-IN, 4/5 PORT SOLENOID VALVE, G92, 84 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, 5 port cassette type valve, 4/5 PORT SOLENOID VALVE, G92, 84.00000 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, 4 POS NC/NC, NON PLUG-IN, 4/5 PORT SOLENOID VALVE, G92, 84 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, PLUG IN, 3-PORT, 4/5 PORT SOLENOID VALVE, G92, 84 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, 5 port cassette type valve, 4/5 PORT SOLENOID VALVE, G92, 79.00000 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less
Fluid: Air; Operating pressure range: up to 0.7Mpa; Valve effective area mm² (Cv factor):P to A/B 3.0 to 3.7 (0.17 to 0.21)A/B to R 3.2 to 3.9 (0.18 to 0.22); Coil rated voltage: 24, 12, 6, 5, 3DC; Response time: minimum 10 or less
Fluid: Air; Operating pressure range: up to 0.7Mpa; Valve effective area mm² (Cv factor):P to A/B 3.0 to 3.7 (0.17 to 0.21)A/B to R 3.2 to 3.9 (0.18 to 0.22); Coil rated voltage: 24, 12, 6, 5, 3DC; Response time: minimum 10 or less
Size: 3/4, 1, Thread: NPT, Port Size: 3/4-AV5000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 3/4, 1, Thread: NPT, Port Size: 3/4-AV5000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: -, Flow Direction: -, Q: -
Size: 3/4, 1, Thread: NPT, Port Size: 3/4-AV5000 Only, Option: None, Voltage: 100VAC, Lead Wire: DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: -
Size: 3/4, 1, Thread: NPT, Port Size: 3/4-AV5000 Only, Option: None, Voltage: 100VAC, Lead Wire: Grommet, Surge Suppressor: -, Manual Override: -
Size: 3/4, 1, Thread: NPT, Port Size: 3/4-AV5000 Only, Option: None, Voltage: 110~120VAC, Lead Wire: Grommet, Surge Suppressor: None, Manual Override: Locking (Slotted)