SMC Corporation of America
Elite Part Number Search
Search Results "AS2201FPG-02-06"

36 132 50 41 200 74 60 230 74 60 271 86 70 22 36 110 180 544 612 873 JIS Symbol 1 4 1 2 2 Construction/Parts/Dimensions ANA1-01 to 06 Sound absorbing Case material (PFV ) End plate Hexagonal flats ANA1-06: PP How to Order Cover ANA1-10 to 20 Sound absorbing material Body Tension bolt End plate A1 03 AN Port size Symbol Connection Port size 1 8 01 1 4 3 8 1 2 3 4 02 03 04 06 10 12 14 20 (

L 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 EXH port silencer 63 Silencer is installed in the EXH port. 38 22 Dimensions 13 Silencer P/N Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP This is used when changing piping location.

Pressure 0.5 MPa Load factor 50% Stroke 500 mm VZS Average speed (mm/s) Series VFS VS4 40 50 63 80 100 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VQ7 VZ514--02 (Piping: 6 x 1 m) EVS VFN AS3301F-02-06/AN200-2 Speed controller/Silencer 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ514--02 (Piping: 8 x 1 m) AS3301F

Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP (For VQZ100) This is used when changing piping location.

C6, C8, C10, 02 C6: One-touch fitting for 6 C8: One-touch fitting for 8 75.5 300 (Lead wire length) C10: One-touch fitting for 10 60.5 2-4.5 mounting hole 02: Rc 1/4 41.8 22 23.4 mounting hole 28.5 20 A 4 13 18 SMC 38 2 Cover dia.1.6 Cross section 0.34 mm2 46.5 R3 28.6 7.1 Manual override (For C6, C8) M5 X 0.8 external pilot port 10.5 (Only external pilot style (R)) (For C10) (For 02) 38.5

AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Valve Mounting VS After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below.

sub-plate ITVH 02 14 03 38 04 12 4 ITVX A M5 M5 (3) (3) 1 01 18 (3) (3) 02 14 PVQ 3 02 14 03 38 04 12 VY1 VY1 VBA VBAT Body ported 5 04 12 VY1B0-X39 (5) 06 34 10 1 AP100 7 10 1 1 14 12 1 14 9 14 1 12 2 20 2 Note 3) Only bracket or foot may be mounted.

Mist Separator, Exhaust Cleaner For VBA40A-04 For VBA42A-04 For VBA43A-04 Model For VBA10A-02 For VBA11A-02 For VBA20A-03 For VBA22A-03 Description Mist separator Exhaust cleaner AM250C-02 AMC310-03 AM450C-04, 06 AMC510-06 AM550C-06, 10 AMC610-10 Note) Refer to page 1022 for air tanks, page 223 for mist separators and Best Pneumatics No.7 for exhaust cleaners.

For VBA10A-02 For VBA11A-02 For VBA20A-03 For VBA22A-03 Description Mist separator Exhaust cleaner AM250C-02 AMC310-03 AM450C-04, 06 AMC510-06 AM550C-06, 10 AMC610-10 Note) Refer to page 12 for air tanks, Best Pneumatics No. 5 for mist separators and Best Pneumatics No. 6 for exhaust cleaners.

VV5ZS3 02 06 51F 1 D Thread type VK Series VZS3000 Manifold Standard Nil NPT Rc N T F VZ Plug-in type Stacking type manifold base with D-sub connector NPTF G Option Port size VF Rc 1 8 02 Rc 1 4 01 U side Connector mounting direction VFR Connector mounting position Symbol Applicable stations Embedded type One-touch fitting Applicable tubing O.D.: 6 C6 VP4 U D U side D side 2 to 8 2 to 8 9

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS090 Series 5-14 HRX-OM-T004 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-R028 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

AN20-02 AN20-02 AN20-02 AN40-04 AN40-04 Air operated type AN20-02 AN40-04 AN40-04 VXF(A)21AA(B) VXF(A)22AA(B) VXF(A)23AA(B) VXF(A)24AA(B) VXF(A)25AA(B) VXF(A)26AA(B) Note) Spring is shipped together with the product, but not assembled. 9 2 Port Solenoid Valve/Air Operated Valve For Dust Collector Series VXF2/VXFA2 Construction Solenoid Valve Type Air Operated Type VXF2 B<

Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.

Body size Metric size Inch size 3 4 5 6 1/8 1/4 3/8 1/2 07 09 11 13 06 08 10 12 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 01 02 03 04 1/8 1/4 3/8 1/2 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.

Length 38 62 72 90 104 114 135 140 78 111 119 147 179 191 236 277 Flat washer Hexagon nut AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 AS-31B AS-32B AS-33B AS-34B AS-35B AS-36B AS-37B AS-38B AS-41B AS-42B AS-43B AS-44B AS-45B AS-46B AS-47B AS-48B AS1002F-01 AS1002F-03 AS1002F

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS Series 5-14 HRX-OM-M091 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-Q033 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS100/150 Series 5-14 HRX-OM-S010 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

LVH Connection LVD 02 03 04 06 10 12 14 20 1 4 Thread type Nil T F N Refer to the table (2) given below for availability. 3 8 1 2 3 4 Rc NPTF G NPT Thread LVQ Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LQ 1 4 1 2 LVN 32 40 50 For 32A For 40A For 50A Flange TI/ TIL PA Refer to the table (1) given below for availability.