SMC Corporation of America
Elite Part Number Search
Search Results "AC20C-02G-V-R-D"

V 12 V Relay, PLC Grommet 24 V Yes IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V 3-wire (NPN equiv.)

D E R L U B R I C AT O R S E R I E S NAL NAL800-N12 (1 14 NPT) NAL800-N14 (1 12 NPT) NAL900-N20 (2 NPT) T E C H N I C A L SPECIFICATIONS D I M E N S I O N S L U B R I C AT O R NAL800 NAL900 Max Supply pressure 1.5MPa / 220PSI Max Operating Pressure 1MPa / 145PSI Operating Temp Range 5~60C /40~140F Recommended lubricant Turbine oil #1 (ISO VG32) Bowl Polycarbonate Pipe Size 114, 112 2 Min

voltage drop: 1.5 V or less PF2MC7###-##-C#-### NPN (1 output) + Analogue (1 to 5 V) output type PF2MC7###-##-D#-### NPN (1 output) + Analogue (4 to 20 mA) output type Maximum applied voltage: 28 V Maximum load current: 80 mA Internal voltage drop: 1.5 V or less C: Analogue output: 1 to 5 V Output impedance: 1 k D: Analogue output: 4 to 20 mA Maximum load impedance: 600 Minimum load impedance

Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63. Consider using the in-line electrical entry type. Switch Mounting Bracket: Part No. 25 to 63: M9(V)/M9W(V)/M9A(V) Bore size (mm) Auto switch model 16, 20 25 to 63 D-M9/M9V D-M9W/M9WV D-M9A/M9AV BMG2-012 BMG2-012 Besides the models listed in How to Order, the following auto switches are applicable.

R CJ2 SW1 EE EE KK KK CM2 WA B D E B D ??

Temp. upper/lower 4 Fig.9-3 limit alarm occurrence 9-1 Alarm 9.2 Alarm indication Blink E R R 1 4 T h e r m o s t a t A l a r m M O D E < S h u t o f f Fig.9-1 Alarm indication in the event ERR14 arises Blink E R R 1 4 P B R a n g e M O D E < 2 . 0 C Fig.9-2 Alarm indication in the event ERR14 arises during PB range setting input Light W R N P V < 2 6 . 6 C # 1 S V 2 5 . 0 C M O D E N

Applicable pad 04U/06U/08U Applicable pad 10U/16U Applicable pad 25U/32U Applicable pad 40U/50U 4.9 30 R 30 R R 25 30 R R R R 10.5 9.5 2 8 9 25 R 2 0.5 6 7 7 8 R R R R R R 45 45 45 2.7 1 R R 2.5 4.5 5 6.6 R 2.5 3.8 4.9 3.5 5 6 7.9 R 4.5 8 9 11.7 11.7 Note) R part has to be smooth with no corners.

For low differential pressure Rated pressure range 0 to 2 kPa C 0 D 2 kPa F 0.2 kPa Range 1 0.6 4 2.4 A C E F B D A C E F B D Pressure Differential pressure Pressure Differential pressure 848 Pressure Sensor Controller Series PSE300 Internal Circuit PSE30 NPN open collector output (2 outputs), Max. 30 V or 80 mA, residual voltage 1 V or less Analog output: 1 to 5 V Output impedance: Approx

30 50 Lead 8: LEKFS32(L/R)EB Lead 8: LEKFS32(L/R)EB 40 Work load: W [kg] Work load: W [kg] 20 30 Lead 16: LEKFS32(L/R)EA Lead 16: LEKFS32(L/R)EA 20 10 Lead 24: LEKFS32(L/R)EH Lead 24: LEKFS32(L/R)EH 10 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 Speed: V [mm/s] Speed: V [mm/s] Vertical LEKFS40(L/R)/Ball Screw Drive Horizontal 70 60 30 Lead 10: LEKFS40(L/R)EB Lead 10: LEKFS40

D side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) 3 m 2-5-11 Base Mounted 12 Series VQ4000 Kit (D-sub connector kit) F Applicable connector: D-sub connector (25P) (Conforming to MIL-C-24308) 70 38 2-Rc 1/8 (Pilot EXH port) 18 18 17.5 PE 30 42 R2 R1 P 1 3 5 2n-Rc 1/4, 3/8, C8, C10, C12 4(A), 2(B) port SMC 6-Rc 1/2 Rc 1/4: Rc 1/4 thread 1(P), 5(R1), 3(R2) port

Style D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.

1 1000 V = D 2 x L x (L) For the conductance, the equivalent conductance can be found in 8.

terminal: D, DIN terminal with indicator light: DL) Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U V W VNB2V-10A VNB2V-15A VNB3V-20A VNB4V-25A 3 8 1 2 3 4 1 72.5 80.5 170.5 173.5 180.5 24.3 2.3 25 34 55 75 87 97 114 126.5 52 26 4.5 63 42 28 14 28.3 33.3 2.3 2.3 30 35 43 49 17.5 20 84 100 92 108 80 81 92 93 102 103 125.5 138 154 182 198 185 201 192 208 62 72 31 36 5.5

Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/ 3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Red LED lights when ON Indicator light Lead wire D-A90(V)/D-A93(V) Oilproof vinyl heavy insulation cable, 2.7, 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m D-A96(V) Oilproof vinyl heavy insulation cabele, 2.7, 0.15 mm2 x 3 cores (Brown, Black

Add an in front of the part numbers for solenoid valves, etc. to be mounted. 1 2 3 4 7 8 J 5 6 100 V 200 V 110 V 220 V 240 V 48 V 230 V 24 V 12 V U side 1 2 3 4 5 n Station D side AC Note) Note) Enter the products part number in order, counting the 1st station from the left in the m a n i f o l d arrangement, when viewing the individual port in front.

Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 283 314 220 251 157 188 94 126 314 63 OUT 20 10 236 212 189 165 142 118 94 71 47

Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 314 283 251 220 188 157 126 94 63 314 OUT 20 10 236 212 189 165 142 118 94 71 47

Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/ 3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Red LED lights when ON Indicator light Lead wire D-A90(V)/D-A93(V) Oilproof vinyl heavy insulation cable, 2.7, 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m D-A96(V) Oilproof vinyl heavy insulation cabele, 2.7, 0.15 mm2 x 3 cores (Brown, Black