Bore Size: 12mm, Symmetric Type: Symmetric, Stroke: 20mm, Adjuster: Extension End Absorber + Retraction End Adjuster, Function: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -

/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt xing brackets 2 pcs. (including 6 M8 bolts) Note 10) Weight (dry state) kg Approx. 180 Approx. 215 Approx. 280 Note 1) When the ambient temperature or circulating uid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 186-1).

Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.   25A-PFM7 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide. The 3-digit LED display can be red or green, changing when a set point is reached.  Either instantaneous or accumulated flow can be shown. 

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.   25A-PFM7 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide. The 3-digit LED display can be red or green, changing when a set point is reached.  Either instantaneous or accumulated flow can be shown. 

Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Fluid: air; Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC; Base mounted or Body ported; Ambient & fluid temperature: 50°C; Series 25A-SY5000/7000 is compatible with secondary battery applications

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

Series 25A-AV-A soft start-up valves allow the user to set the initial rate of system pressurization to minimize system shock. The 25A specifies that this product is compatible with secondary battery. When deactivated, the valve quickly exhausts the system for safe servicing of equipment.

Bore Size: 12mm, Symmetric Type: Symmetric, Stroke: 100mm, Adjuster: -, Function: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

size 32 3 to 4 1 125 15 to 17 3 100 8 to 10 2 80 6 to 8 1.5 63 4 to 5 1.5 50 3 to 5 1 40 3 to 4 1 100 st Extra 50 st 344 Series CL1 40 to 100 Replacement Procedure of Seal 3 6.

30 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 30 st or less Over 300 st Over 25 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 25 st or less Over 300 st Over 30 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 30 st or less 28 52 300 100 75 77 128 200 128 178 24 52 174 198 42 54 92 80 14.5 25.5 74 28 156 180 140 17.5 M12 x 1.75 32 40 50 63 117 117 12 16

kPa to 0.6 100 kPa to 0.6 100 kPa to 0 100 kPa to 0 100 kPa to 0 100 kPa to 0 100 kPa to 0.6 100 kPa to 0.6 N.C.

(Target position) time constant time constant speed [r/min] [ms] function [10STMm] [ms] [ms] 1 5.00 3000 100 150 100 1 2 -6.00 2000 100 100 0 3 3 3.00 3000 50 50 0 0 (Note) Note.

2 Driver type* Compatible driver Power supply voltage [V] Nil Without driver A1 LECSA1 100 to 120 A2 LECSA2 200 to 230 B1 LECSB1 100 to 120 B2 LECSB2 200 to 230 C1 LECSC1 100 to 120 C2 LECSC2 200 to 230 S1 LECSS1 100 to 120 S2 LECSS2 200 to 230 LEY25: 200 mm or less LEY32: 100 mm or less *3 Rod flange is not available for the LEY25 with stroke 30 mm and motor option With lock. *4 Head