SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20A-T-01"

Function: 2 (2 Position Double), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)

Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 3 (Common), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 2 (200VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)

Function: 2 (2 Position Double), Piping: 3 (Body Ported), Exhaust: 3 (Common), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: E (Push-turn Locking Lever Type), A, B Port Size: 01 (1/8)

Function: 3 (3 Position Closed Center), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)

Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)

Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)

Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: U (With light/surge voltage suppressor (Non-polar type)), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)

Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 300mm), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8), Thread: T (NPTF)

-01-06 VZM450-01-06S Toggle lever VZM450-01-08 VZM450-01-30R VM-30CR Red VM-30CB Black VZM450-01-30B Push button (Mushroom) VM-30CG Green VZM450-01-30G VM-30CY Yellow VZM450-01-30Y VZM450-01-32R VM-32CR Red VM-32CB Black VZM450-01-32B Push button (Extended) VM-32CG Green VZM450-01-32G VM-32CY Yellow VZM450-01-32Y With a set of red, black, green, yellow VM-33C Push button (Flush) VZM450-01

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

Series: 5 (10-SY5000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: W3 (M8 Connector, w/Connector Cable, 1000mm), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: 01 (1/8), Thread: T (NPTF), Bracket: F2 (w/Side Bracket)

Series: 5 (10-SY5000), Actuation: 1 (2 Position, Single), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: WO (M8 Connector, w/o Connector Cable), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: 01 (1/8), Thread: T (NPTF), Bracket: F2 (w/Side Bracket)

Series: 5 (10-SY5000), Actuation: 3 (3 Position, Closed Center), Coil Specification: None, Voltage: 5 (24 VDC), Electrical Entry: WO (M8 Connector, w/o Connector Cable), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-Locking Push Type, A, B Port Size: 01 (1/8), Thread: T (NPTF), Bracket: F2 (w/Side Bracket)

Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)

Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Connector, w/o Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)

Actuation: 1 (2 Position Single), Piping/EXH: 23 (Body Ported), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8 w/Sub-plate, Piping 23 w/o Sub-plate), Thread: T (NPTF)

Series: 344 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: Rc, Actuation: A (N.C., Normally Closed)