Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F02 (G1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]
Type: [Flow Switches] Flow Switch, Fluid Type: Air / Nitrogen Gas / Carbonic Acid Gas / Argon, Flow Range(l/min): 100~Less than 500, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Current, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/4] 1/4, Pressure Resistance
Fluid Type: Air / Nitrogen Gas / Carbonic Acid Gas / Argon, Flow Range(l/min): 100~Less than 500, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Current, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Straight), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1,
Fluid Type: Air / Nitrogen Gas / Carbonic Acid Gas / Argon, Flow Range(l/min): 100~Less than 500, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Current, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings (Straight), Plumbing Thread Type: -, Plumbing Thread Nominal: -, Pressure Resistance(MPa): 1,
Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: 6.35(1/4inch), Liquid contact parts material: Resin + Metal, Mounting Hole: Presence, Display:
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: G1/4, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,
This is a legacy product, and replaced bySY5100B-5U1-NA, VALVE, SOL, VALVE, NEW SY5000 VALVE, 1F, NEW SY5000 OTHER SIZE RATING, .18077 lb
ETL500-F-0-AT-16-NA-ST-0600-AP-MP-3-LT (Large Tube, 3 Roller, Stepper Motor) Download Pumphead Datasheet Download Stepper Datasheet Download Tubing Datasheet Pumphead Datasheet.
ETL500-F-0-AT-16-NA-ST-0600-AP-MP-4-MT (Med Tube, 4 Roller, Stepper Motor) Download Pumphead Datasheet Download Stepper Datasheet Download Tubing Datasheet Pumphead Datasheet.
ETL500-F-0-AT-16-NA-ST-0600-AP-MP-3-MT (Med Tube, 3 Roller, Stepper Motor) Download Pumphead Datasheet Download Stepper Datasheet Download Tubing Datasheet Pumphead Datasheet.
ETL500-F-0-AT-16-NA-ST-0600-AP-MP-4-LT (Large Tube, 4 Roller, Stepper Motor) Download Pumphead Datasheet Download Stepper Datasheet Download Tubing Datasheet Pumphead Datasheet.
ETL500-F-0-AT-16-NA-ST-0600-AP-MP-4-LST (Large Silicone, 4 Roller, Stepper Motor) Download Pumphead Datasheet Download Stepper Datasheet Download Tubing Datasheet Pumphead Datasheet.
ETL500-F-0-AT-16-NA-ST-0600-AP-MP-3-LST (Large Silicone, 3 Roller, Stepper Motor) Download Pumphead Datasheet Download Stepper Datasheet Download Tubing Datasheet Pumphead Datasheet.