Thermo-Con Series Thermo-electric (No-freon) Temperature Controller Features Series expanded from small through medium sizes Specifications Cooling capacity* Control accuracy Temperature setting range Model Power supply HEC105W H110W AC200V, 3A HEC205W 230W AC200V, 5A 1060 0.03 HEC405W 350W AC200V, 4A 240W type 450W type HEC605W 600W AC200V, 5A HEC1005W Prototype 1005W AC200V, 10A 40% energy
5A 0V +24V +24V 0V 2 x M4 Mounting hole Shown with cover removed. 60 1711 Series EX510 Parts Description i w t Output Unit No.
Lead wire length Nil 0.6 m 30 3 m Example) ZSE1-00-15CN-X129 ZS-20-5A-50 1 pc. 1 pc. 50 5 m 1086 Ejector Valve Unit Series ZYY/ZYX Internal Circuit and Wiring Example How to Set the Pressure How to Use the Connector 1. Attaching and detaching connectors ZSE1-14, -15 The ON pressure is set with the pressure setting trimmer. High vacuum settings are obtained by turning it clockwise.
Line filter: 250VAC, 3 to 5A class varistor: for 39 to 47VDC operation Warning Caution VEA25 Appearance VEA250 Adjustment trimmer GAIN NULL DITHER Adjustment trimmer VEA251/2
5A 15A 10A 10A Compressor input 180/200W 50/60Hz 385/440W 50/60Hz Heater input 220W 420W Note 6) Nominal filtration rating 0.01m (99.9% filtration efficiencyNote 6) Buili-in filter specifications Cleanliness of the filter outlet side Particles of 0.3m or more: 3.5 particles/L(ANR)or less Note 6) Protective Overcurrent protection Overload relay devices Heater overheat prevention Thermostat
Lead wire length Nil 0.6 m Example) ZSE1-00-15CN-X129 ZS-20-5A-50 1 pc. 1 pc. 30 3 m 50 5 m 13-8-8 9 Ejector Valve Unit Series ZYY/ZYX How to Set the Pressure How to Use the Connector Hysteresis Hysteresis is the difference between the pressure at which the output signal turns ON and the pressure at which it turns OFF. It turns ON at the set pressure. 1.
SOL.A 3A () (+) Station 3 SOL.B 3B () (+) SOL.A 4A () (+) Station 4 SOL.B 4B () (+) SOL.A 5A () (+) 2.
phase AC100/100 , 110VVoltage fluctuations10% Power source 200V AC(50/60Hz) Single phase AC200/200 , 220V Electrical Specification Voltage fluctuations10% 100V AC(50/60Hz) 2.4/2.5 3.0/3.1 5.7/5.7 Operating current (Note 2) A 200V AC(50/60Hz) 1.2/1.3 1.5/1.5 3.4/3.0 Power consumption (Note 2) W 100V AC,200V AC (50/60Hz) 180/202 208/236 385/440 100V AC 10A Circuit Breaker (Note 3) 200V AC 5A
(P.59) 11 - 3. 3.1 (DC24V) DC24V10% 3A 5A A/B 800 / RS485 Modbus EEPROM LED PWR LED ALM L ERR CC-Link L RUN CC-Link 20m oC40 oC() 0 90%RH ) oC60 oC () -10 90%RH ) 2 4.9m/s IP20 50MDC500V 170g() 190g(DIN ) [CC-Link ] CC-Link Version 1.10 1 2 4 (/) 32 /32 4 /4 64 /64 8 /8 128 /128 16 /16 156k/625k/2.5M/5M/10Mbps NRZI (EIA RS485) HDLC 16+X 12+X 5+1) CRC(X
. (+/10%), 50/60Hz Current consumption Max.5A(100V) Max.9A(100V) Max.4A(240V) Max.10A(100V) Max.4A(240V) Max.8A (200V) Max.2.5A(240V) Inrush current 50A or less Over current protection 10A 14A Do not modify or reconstruct the unit.
Install a Ground Fault Circuit Interrupter(GFCI) to the power supply (IDF3E ~ 11E : sensitivity of leak current 30mA and rated current 5A), (IDF15E1 : sensitivity of leak current 30mA and rated current 10A). (Prepare by yourself) Specification of power cable Prepare following power cable.
Length 136016-1A 136016-2A 136016-3A 136016-4A 136016-5A 136016-6A 136016-7A 136016-8A 136016-9A 136016-10A 16 14 1 SRH 28 2 42 3 SRP 56 4 70 5 SRF Tie-rod for centralized supply block 84 6 98 7 ITV 112 8 126 9 IC 140 10 For 1 station 14 mm x 1 station = 14 mm Length ITVH For adding a regulator Tie-rod part no.
9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring will be double wiring (connected to SOL. a and SOL. b) regardless
Individual SUP spacer assembly Individual EXH spacer assembly Note Non plug assembly: ZYY3000-NPA Blanking plate assembly: SX3000-75-1A Individual SUP spacer assembly: SY3000-38-2A SUP/EXH block assembly (for R): SX3000-51-3A SUP block disk: SX3000-77-1A Individual EXH spacer assembly: SY3000-39-2A SUP/EXH block assembly (for S): SX3000-51-4A SUP/EXH block assembly (for RS): SX3000-51-5A
Po.l l{lntel Itodel (Rell f( FH RD nt 5A s0 Boh Sizew4l (s) itlllitilxl ,5 NI210{9141 trR)0rMl.l5 5.5 o < 41.3 50.8 44.528.6 [5 RFlll36rl.5 Nl2t293r?9 .R)0EMt.25 5.5 9.5 4t.3 58.844.5?8.6 M5 30 Prtl!+-l2 M5t?
Electric specifications of the power supply HEC006 AC200-220V, 50/60Hz 5A Single phase 2-wire type + GND (PE) line HEC012 AC200-220V, 50/60Hz 10A Single phase 2-wire type + GND (PE) line Do not bend, pull or bind the power supply cable with a strong force.
VCA Pipe material Seal material NBR FKM EPDM NBR FKM EPDM Symbol Nil A B G H J Series 10, 20 VVDW 2 0 5A VCB Brass (C37) Series VCL Stainless steel 1 2 10 20 VCS VCW Series 30 VVCW20-5A 253 Compact Direct Operated 3 Port Solenoid Valve for Water and Air Series VDW200/300 How to Order Valves (Single Unit) VD W 2 50 1 G 2 01 For Water, Air, Vacuum Made to Order (Refer to page 255.)
Dd9 Knuckle 40, 50, 63 80 100 3 x 18l 3 x 18l 4 x 25l 4 x 25l 4 x 30l 4 x 36l CDP-2A CDP-3A CDP-4A CDP-5A CDP-6A CDP-7A 10 0.046 0.076 12 0.050 0.093 16 0.050 0.093 18 0.050 0.093 20 0.065 0.117 25 0.065 0.117 46 55.5 71 76.5 83 88 4 4 5 5 5 6 3 3 4 4 4 4 38 47.5 61 66.5 73 78 Material: Rolled steel Applicable bore size (mm) 40 50, 63 80 100 d D H B C Part no.
SOL.A 1A () (+) 1B () (+) Station 1 SOL.B 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A () (+) 2B () (+) Station 2 SOL.B SOL.A 1.