SMC Corporation of America
Elite Part Number Search
Search Results "LEFS25S2A-100-R"

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs), Connector: L3 (L-type Plug Connector), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System PE Port

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: E (Vacuum Break

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: E (Vacuum Break

Bracket (Option) 11 $ 40 $ $ 20 $ $ 21 $ None Yes Nil S None Bracket Nil Note 1) 100 and 250 L/min types with flow adjustment valves are not available. Note 2) The flow adjustment valve of this product is not suitable for applications which require constant adjustment of flow rate.

. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: E (Vacuum Break

20 80 Lateral load F 10 60 40 80 70 60 50 40 30 30 20 Point of application L mm 80 60 40 120 100 Point of application L mm 4 Escapements Series MIW/MIS 12, 20 How to Order Finger options Nil: Basic type (Standard type) 1: Tapped on upper and lower faces 2: Tapped on all faces (5 surfaces including end surface) Stroke 12 20 12 20 12mm 20mm MIW only accommodates a stroke of the same length

Information End Lock Cylinder Series CBJ2 / 16 Cylinder stroke (mm) 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available in 1 mm increments without stroke adjustment with a spacer. For types with auto switch, refer to Minimum Strokes for Auto Switch Mounting on page 2.

2 w y r !0 e 1 New PFA Body 2 New PFA Sensor 3 Super PFA Tube 4 PPS Housing A 5 PPS Housing B 6 PPS Housing C 7 POM Bushing 8 PPS Cap 9 FKM Gasket 10 FKM O-ring 11 SUS304 Thread 12 PVC Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !

Magnet: D (Built-in Magnet), Mounting: B (Basic), Style: N (Rubber Bumper), Bore Size: 40mm, Thread: Rubber Bumper: Rc: 20 to 100; Air Cushion: M5: 20, 25; Rc: 32 to 100), Seal Material: R (NBR Seals, Nitrile Rubber), Stroke: 25mm

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Stations: 05 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: C [Vacuum Pump System PE Port Female

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump

Also, when the sealant tape is used, leave approximately 1 thread ridge exposed at the end of the threads. 100 2d D L 1 = Mandrel 5 - 2. Specific Product Precautions (2) (3) Check the model, type and size before installation.

How to Order 100 IP200 Applicable stroke 25 to 300 mm * Manufacture of strokes in 1 mm increments is possible. Specifications (No load) Note 1) Replacement Parts Supply pressure 0.3 to 0.7 MPa Input pressure 0.02 to 0.1 MPa Part no.

Exhaust port effective area 21 mm2 Port size 3-PT 1/4 Filtration 40 mesh (Gauze) Weight 0.8 kg 1073 AEP100-02 Operating Conditions Working Principle Bore size 40 mm or more Stroke 100 mm or more Cylinder 100 mm/s or more Piston speed 6 / 4 10 m or less Tubing length on IN side 8 / 6 5 m or less Circuit Example Nylon tube 6/4.5 Max. length 10 m 8/6 Max. length 5 m When the exhaust