SMC Corporation of America
Elite Part Number Search
Search Results "JSX31V-SF702N-5GS-D"

Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration MHZ Auto switch Hysteresis L L Auto switch operating position (ON) Finger position MHF Auto switch operating position (OFF) MHL D-M9 D-F9W D-M9V D-F9WV Model MHR Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close 4.5 4.5 4.5

MDHR3-10 1122MDHR3-15 1122H L H When auto switch D-M9V is used When auto switch D-M9 is used When auto switch D-M9V is used Max. protrusion of auto switch from edge of body: L, H Max. protrusion of auto switch from edge of body: H (mm) (mm) D-M9 D-M9V D-M9V Auto switch model Auto switch model L H 1.3 The auto switch will not protrude in the case of D-M9. 2.3 H 939 Rotary Actuated Air

BBA4: D-C7/C8/H7 "D-H7BAL" switch is set on the cylinder with the screws above when shipped.

Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration MHZ Auto switch Hysteresis L L Auto switch operating position (ON) Finger position MHF Auto switch operating position (OFF) MHL D-M9 D-F9W D-M9V D-F9WV Model MHR Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close 4.5 4.5 4.5

For details, refer to the Best Pneumatics Vol. 3. 4-5-1 2 Series VK300 How to Order Electrical entry D: DIN terminal DO: DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) For the connector part number, refer to page 4-5-10.

Product Profile: ISO Standard Solenoid Valve: Size 1, 2 Rubber Seal Series VP7-6/7-8 Solenoid valve conforming to ISO standard Size (1)/VP7-6 Size (2)/VP7-8 (Rubber seal) Single solenoid (FG-S) Double solenoid (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) 2 position 3 position Closed center (FHG-D) Exhaust center (FJG-D) Double pilot check (FPG-D) Pressure center (FLG-D) Courtesy

D Display flow range The range of measured values that can be displayed for a product with a digital display. F Fluid temperature Range of fluid temperature that can be measured by the product. Stands for "full span" or "full scale", and indicates varied display value and analogue output range at rated value.

Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration Auto switch Hysteresis L L Auto switch operating position (ON) Finger position Auto switch operating position (OFF) D-M9 D-M9W D-M9V D-M9WV Model Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Hysteresis 6.5 6.5 6.5 6.5

Printed in Japan. 1st printing August, 1998 D-SMC.L.A. P-69.5 (JT)

Parenlneses CPA1 BN do Boot with Boot' BORE D E G'GB J K M MM N P H z.

length) 35 (DIN 36.2) 21.5 R P R P 37.9 57.1 [59.3] 2-4.5 (For mounting) V100 (4.9) 1/8 (P, R port) SY Manual override L2 4.5 SYJ L1 VK VZ (Station 1) (Station n) (Light/Surge voltage suppressor) VT VP + + + + 54.1 [61.1] VG 38.7 25.5 A A VP (Pitch) P=16 17 One-touch fitting (A port) Applicable tubing O.D.: 4, 5/32" 7.5 S070 VQ VKF L plug connector (L) M plug connector (M) DIN terminal (D)

Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W No. of auto switches mounted 314 283 251 220 188 157 126 94 63 314 OUT D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 10 20 236 212 189 165 142 118 94 71 47

Nil U 6 (Light gray) 1/4" (Orange) D side 1 2 3 Note) A DIN rail with the length specified by the number of stations is attached to the manifold.

Power supply/Output connection cable (2 m) ZS-28-A D Bracket With M3 x 5L (2 pcs.) ZS-28-B Mounting screw (M3 x 8L) Sensor connector 1 pc. ZS-28-C Panel mount adapter With M3 x 8L (2 pcs.) ZS-27-C Panel mount adapter Panel mount adapter + Front protective cover With M3 x 8L (2 pcs.) ZS-27-D Note) These options are not attached in the factory, but packed together with it for shipment.

KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R1/4 14 52 46 D H1 A L1 Reference dimensions after R thread installation Low noise nozzle with male thread: KNS (mm) thread L1 A Width across flats H1 D Connection Nozzle size Part no.

Use a D-class ground connection (ground with a resistance of less than 100). The cross sectional area of the grounding cable shall be 2 mm2 or more. The Grounding point should be as near as possible to the controller. Keep the grounding cable as short as possible.

For single power supply use COM D COM D is receiving data: Lights up 2 COM D is having no data to receive: Goes off 1: Refer to "Operation Manual" for the extension diagnosis information. 2: It is lit when input unit is connected and communicating normally.

cable (26P) without cable Flat ribbon cable (26P) with 1.5 m cable Flat ribbon cable (26P) with 3.0 m cable Flat ribbon cable (26P) with 5.0 m cable 25 pins IP40 compliant IP67 compliant 1 to 12 stations (24) FD0 FD1 FD2 FD3 D-sub connector (25P) without cable D-sub connector (25P) with 1.5 m cable D-sub connector (25P) with 3.0 m cable D-sub connector (25P) with 5.0 m cable 1 to 12 stations

F9NV F9PV 154 154 154 Long Stroke Slide Table MXW Series 2 color indication solid state switch: D-F9BW (V), D-F9NW (V), D-F9PW (V) Switch operation range Stroke (mm) Model 25 50 75 100 125 150 175 200 225 250 275 300 A 49.5 28.5 24.5 24.5 24.5 24.5 B 82.5 103.5 128.5 153.5 178.5 203.5 4 MXW 8 W 35.5 14.5 10.5 10.5 10.5 10.5 V 96.5 117.5 142.5 167.5 192.5 217.5 A 48 28 28 28 28 B 107