Body Size: 30A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: CG (C + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 30A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: CG (C + G), Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: CG (C + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: CG (C + G), Attachment: Standard, Semi-Standard 1: 8 (Metal Bowl with Level Gauge), Semi-Standard 2: Standard
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Configuration Data (AX) Index Name / Meaning Type Value 80x0:0 Slot x: Module identification USINT 10 80x0:01 Address of the module UINT Slot No. 80x0:09 Module PDO group UINT 1 80x0:0A Module ident DINT 32 80x1:0 Slot x: Unit Parameters USINT 13 80x1:01 Monitor short circuit (in) Enum0807 0=Disable 1=Enable 80x1:03 Monitor over range Enum0807 0=Disable 1=Enable 80x1:04 Monitor under range
DC (+) 1 NC 2 Flow direction DC () 3 OUT 4 8 Digital Flow Switch for Water Series PFW How to order 20 03 27 PFW7 Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications 27 67 NPN (2 outputs) PNP (2 outputs) Piping port size 03 04 06 3/8 1
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
Element Replacement] (P31-32) and [11-2. Bowl Assembly Replacement] (P29-30).
Element Replacement] (P31-32) and [11-2. Bowl Assembly Replacement] (P29-30).
How to Order VR 12 1 06 0 F Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 2 1/8 standard 1/4 standard 23 04 06 08 10 01 03 07 09 11 3.2 4 6 8 10 1/8" 5/32" 1/4" 5/16" 3/8" With One-touch fitting Use 1/8" tubing for 3.2. 1 Series VR120F Application Circuit Examples Self holding circuit 1. When "A" is turned ON, output goes ON. 2.
10 10 150.5 15 26 54 10 8 M8 x 1.25 6 11 25 to 800 25 to 650 35 50 32 80.5 27 70 46 21 52 24 20 28.5 10.5 40 10 12 162.5 17 27 59 13 11 M8 x 1.25 9 11 25 to 800 25 to 650 35 60 32 98.5 27 85 23 64 24 20 28.5 13.5 40 10 15 17 26 67 18 11 M10 x 1.25 9 48.5 174 14 25 to 750 25 to 600 40 70 37 32 23 78 25 15.5 52 14 17 21 30 72 23 13 M12 x 1.75 11 117.5 102 55 26.5 36 189 17 25 to 750 25 to
(Request):010307F5 [CR][LF] (Response):01030E00D40D02010A [CR][LF] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 03 Function 03 Function 0 Head address of specified register 0E Quantity of bytes to read 0007 Quantity of register to read 00D4 Information of 0h (circulating fluid discharge temperature) F5 LRC 0 Information of 0001h (Reserved)