SMC Corporation of America
Elite Part Number Search
Search Results "REBR15-200-M9NWSBPC"

The maximum speed will be 141 mm/s. 50 32 25 20 10 5 16 Load mass (kg) 10 (2.5) 6 [Double acting (D), Single acting, Spring return (S)] 6 [Single acting, Spring extend (T)] 1 0.5 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.

Fitting marking for applicable tubing material Connection Tubing Barb fittings Barb elbow Barb elbow (H) Soft nylon tubing Polyurethane tubing Made to Order (Refer to page 200 for details.)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BJ (B + J)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BM (B + M)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)