characteristics (Cv factor) 0.04 0.03 Response time 10 ms or less Leakage Zero leakage, either external or internal (at hydraulic pressure) Proof pressure Note 2) 0.38 MPa 0 to 50C Ambient temperature 0 to 50C (with no condenssation) Fluid temperature Note 3) 11 l 20 l Volume of valve chamber Note 4) Free Mounting orientation Enclosure IP40 or equivalent Weight 30 g 34 g (Without sub-plate), 42

1 q t i 385 PF2D Series Dimensions: Remote Type Sensor Unit PF2D504-11/520-13 60 70 176 40 15 A Model PF2D504 PF2D520 9.52 12.7 62 52 42 A 4 x 4.5 52 1 18 PF2D540-19 Internal Circuits and Wiring Examples 78 86 186 -1/2 Analog voltage output Analog current output 56 15 Sensor Monitor PF2D3 Black Output for PF2D3 4 8 Switch output Main circuit Main circuit Main circuit Main circuit 3 7 U DC

1.45mm 0.0571 1.5mm 0.0591 53 0.0595 1.55mm 0.0610 1/16 0.0625 1.6mm 0.0630 52 0.0635 1.65mm 0.0650 1.7mm 0.0669 51 0.0670 1.75mm 0.0689 50 0.0700 1.8mm 0.0709 1.85mm 0.0728 49 0.0730 1.9mm 0.0748 48 0.0760 1.95mm 0.0768 5/64 0.0781 47 0.0785 2mm 0.0787 2.05mm 0.0807 46 0.0810 45 0.0820 2.1mm 0.0827 2.15mm 0.0846 44 0.0860 2.2mm 0.0866 2.25mm 0.0886 43 0.0890 2.3mm 0.0906 2.35mm 0.0925 42

Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation

1.45mm 0.0571 1.5mm 0.0591 53 0.0595 1.55mm 0.0610 1/16 0.0625 1.6mm 0.0630 52 0.0635 1.65mm 0.0650 1.7mm 0.0669 51 0.0670 1.75mm 0.0689 50 0.0700 1.8mm 0.0709 1.85mm 0.0728 49 0.0730 1.9mm 0.0748 48 0.0760 1.95mm 0.0768 5/64 0.0781 47 0.0785 2mm 0.0787 2.05mm 0.0807 46 0.0810 45 0.0820 2.1mm 0.0827 2.15mm 0.0846 44 0.0860 2.2mm 0.0866 2.25mm 0.0886 43 0.0890 2.3mm 0.0906 2.35mm 0.0925 42

Note 5) Min. bending radius (refraction value) (mm) 4 26 42 37 9 Fluid temperature (fixed usage) Material Fixed end Air, Inert gas: 4 to 212F (20 to 100nC), Water, Solvent: 32 to 158F (0 to 70nC) (No freezing) Inner layer: Special fluoropolymer, Outer layer: Special nylon resin Note 1) There may be plasticizer (white powder) deposits on the external surface of the tube.

L* N x 4 N x 8 N x 12 N x 6 N x 12 N x 18 N x 8 N x 16 N x 10 N x 20 N x 12 N x 24 D 18 28 28 24 37 37 31 42 52 52 67 67 TCU0425-1N-X6 TCU0425-2N-X6 TCU0425-3-N-X6 TCU0604-1-N-X6 TCU0604-2-N-X6 TCU0604-3-N-X6 TCU0805-1-N-X6 TCU0805-2-N-X6 TCU1065-1-N-X6 TCU1065-2-N-X6 TCU1208 -1-N-X6 TCU1208 -2-N-X6 LX5.9 + 200 LX4.4 + 200 LX2.9 + 200 LX5.3 + 200 LX3.8 + 200 LX2.5 + 200 LX5.2 + 200 LX3 +

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve Series VCH VCH41/42: 2 Port VCH410: 3 Port VCHC40: Check Valve Pilot Operated 2 Port Solenoid Valve VX2 VXD Series VCH40 VXZ Stable responsiveness VXE Response time dispersion within 2 ms Service life: 10 million cycles VXP VXR Non-collision construction between the iron cores keeps equipment abrasion free.

Refer to front matters 42 and 43 for Safety Precautions and pages 287 to 291 for Precautions on every series. Adjustment Caution 1. When adjusting the outlet side pressure, moment is applied on the adjusting bolt. Support it separately so that moment is not applied to the external pipings.

Three-type dust cover variations for diversified applications Note 1) Note 2) Model Opening/Closing stroke (mm) Mass (g) Operating system Model Cylinder bore (mm) Gripping force (Effective value) N MHQJ2-10D 10 11 4 90 MHZ MHQJ2-16D 6 16 34 180 Double acting MHQJ2-20D 10 20 42 340 MHF MHQJ2-25D 14 25 63 640 MHQJ2-10S 4 10 7.8 90 MHL MHQJ2-16S 6 16 26 181 Normally open MHQJ2-20S 10 20 33 342

Coil rated voltage (V) 24, 6, 12, 48 Allowable voltage fluctuation (%) Power consumption (W) [Current mA] 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200

01: R 1/8 T1: NPTF 1/8 Piping port M5 x 0.8 depth 5 13 13 01: R 1/8 T1: NPTF 1/8 Dimensions/Base Mount Type: ZSE2-0R Grommet type: ZSE2-0R-15 Connector type: ZSE2-0R-15C Pressure setting trimmer Indicator light (Red) Pressure setting trimmer Indicator light (Red) H SET L H SET L 15 15 9 9 2 x M2.5 x 41L Mounting thread 25 25 2 x M2.5 x 41L Mounting thread 31 31 9 600 (3000) 9 600 (3000) 42

Output type Number of outputs 2 points Internal power supply method Integrated power supply method (Power block: supplied from EX9-PE1) Power supply method Output specification Output device supply voltage 24 VDC Max. 42 mA/point (1.0 W/point) Note) Max. 0.5 A/point (12 W/point) Output device supply current Display Yellow LED (Lights when power is turned ON.)

Dimensions/Parts Description EX123-S, EX124-S Position indicator LED Screw terminal block 56.4 11.6 53.8 19 Housing cover Housing cover diagram 19 114 5.5 19.8 EX123: 2 x G1/2 EX124: 4 x G1/2 Conduit port (72.5) 67 EX EX126D-SMJ1 Position indicator LED Screw terminal block Housing cover Housing cover diagram 114 (72.5) 5.5 67 19.8 4 x G1/2 Conduit port 34.8 Power supply fuse for communication 42

Description For VCHN(F)3 VCHN3-EL Sound absorbing material Connecting thread 3/4 1 11/4 11/2 For VCHN(F)4 VCHN4-EL Sound absorbing material Torque 28 to 30 36 to 38 40 to 42 48 to 50 2. Do not apply a lateral load on the main body during or after mounting. 3.

Refer to front matters 42 and 43 for Safety Precautions. Operation in Vacuum Power Source Selection Caution Caution When the product is used in vacuum, apply vacuum pressure to A (2) port. The pressure at P(1) port should be larger than the pressure at A(2) port. This product makes proportional control possible with constant current.

PNP Blue Continuous load current 100mA Enclosure IP67 Housing material Aluminum alloy White Output display ClampRed UnclampYellow Brown Voltage display Green Clamp Cylinder Without Arm Clamp arm CKZT 25 105 DCL781EL CKZ 25 42 A 781EL R Bore size Bore size Special Product Number Special Product Number 25 25 25 25 Arm mounting position Arm opening angl The special product numbers in the following

Coil type Nil Standard With power saving circuit (24, 12 VDC only) T For sub-plate type, type 41, S41, 42, S42 manifold Power saving circuit is not available for W type.

Refer to page 123 for details. 42 Series CJ2 Air Cylinder: Standard Type Double Acting, Single Rod Specifications 10 6 16 Bore size (mm) Double acting, Single rod Action Air Fluid 1 MPa Proof pressure 10.7 MPa Maximum operating pressure 0.12 MPa 0.06 MPa Rubber bumper Minimum operating pressure CJ1 0.1 MPa Air cushion Without auto switch: 10C to 70C, With auto switch: 10C to 60C Ambient

Grease pack (10 g) 1 pc. 84.8 IN 25 42 59 CQSY16-PS 12 6 113 OUT 34 57 79 CQSY20-PS REA 151 IN 45 75 106 CQSY25-PS 16 8 201 OUT 60 101 141 When only grease for maintenance is necessary, please order by the following part numbers.