Series: Class 3, Coil Voltage: 110VAC 50/60HZ, Electrical Entry: Grommet, Orifice: ø5mm, Port Size: 03 [3/8 (10A)], Thread: -, Material: -, Option: -
(mm) Port size Pressure valve ASR430F-02 ASR530F-02 ASR530F-03 ASR630F-03 ASR630F-04 6 8 10 12 Flow valve ASQ430F-02 ASQ530F-02 ASQ530F-03 ASQ630F-03 ASQ630F-04 R1/4 R1/4 R3/8 R3/8 R1/2 Pilot valve and two-way flow control valve integrated into a single construction Specifications Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Variable 0.1 to 0.3 MPa Set pressure range Fixed (option
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in6R 3/8-03-06AS3211FG-03-06-03-06-03-06
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 3/8-03-08AS3211FG-03-08-03-08-03-08
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in10R 3/8-03-10AS3211FG-03-10-03-10-03-10
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 3/8-03-12AS3211FG-03-12-03-12-03-12
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 3/8-03-08AS3211FG-03-08-03-08-03-08
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in6R 3/8-03-06AS3211FG-03-06-03-06-03-06
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in10R 3/8-03-10AS3211FG-03-10-03-10-03-10
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 3/8-03-12AS3211FG-03-12-03-12-03-12
Series VMG has a large effective area of 0.05in² (30mm²), without nozzle. Pressure loss is 0.725psi (0.005MPa) or less when nozzle bore size 2.5mm is used. Piping direction is optional from the top or bottom. Available nozzles include: male thread; high efficiency; low noise w/male thread; and extension nozzles., BLOW GUN, CONNECTORS, BLOW GUNS, EX, VMG BLOW GUNS, 0.55823 lb
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Body Size: 3 (3/8 Basis), Body Material: 2 [SCS14 (Stainless Steel)], Thread: F [G(PF)], Port Size: 03 [3/8 (15A): PA3]
Size: 30, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: BE (B+E), Specifications: 1 (0.005 to 0.2 MPa Setting)
Size: 40, Backflow Function: K (Backflow Function), Thread: F (G), Port Size: 03 (3/8), Accessory: G (Round Pressure Gauge w/Limit Indicator)
Size: 30, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: EH (E+H), Specifications: 3 (0.008 to 0.6 MPa Setting)
Size: 30, Backflow Function: K (Backflow Function), Thread: Rc, Port Size: 03 (3/8), Accessory: None, Specifications: 3 (0.008 to 0.6 MPa Setting)
Size: 30, Backflow Function: None, Thread: F (G), Port Size: 03 (3/8), Accessory: B (Bracket), Specifications: 3 (0.008 to 0.6 MPa Setting)
Size: 30, Backflow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory: BE4 (B+E4), Specifications: 3 (0.008 to 0.6 MPa Setting)