When 1 digit = 1 kPa, the pressure is given with an increment of 1 kPa, e.g., 1, 2, 3, , 99, 100. Digit (Min. setting unit) E Error indication With the self-diagnostic function of the Pressure switch, this indicates that there is an error which could cause a switch failure. F Fine adjustment mode Refer to "Fine adjustment of display value".
Axial piping type (25) MXS25-P 92 Max 11.5 Operating port 2-Rc 1/8 35 (mm) J 76 76 76 86 99 140 181 239 279 Model MXS25-10R MXS25-20R MXS25-30R MXS25-40R MXS25-50R MXS25-75R MXS25-100R MXS25-125R MXS25-150R 40 18 35.5 Other dimensions are the same as basic style. 20 Other dimensions are the same as basic style. 8-4-25 26 Series MXS Option Specifications Dimensions of Stroke Adjuster at
Axial piping type (25) MXS25-P Max. 11.5 Operating port 2 x Rc 1/8 (NPT 1/8, G 1/8) 35 (mm) J 76 76 76 86 99 140 181 239 279 Model MXS25-10R MXS25-20R MXS25-30R MXS25-40R MXS25-50R MXS25-75R MXS25-100R MXS25-125R MXS25-150R 80.7 40 D18 -X 35.5 Other dimensions are the same as the basic style.
CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 18 21.5 46 47 20 23 5 20 6.5 6.5 5 NS 12.5 13 11 7.5 35 + Stroke 46.5 + Stroke 11.5 20 4-M4 x 0.7 Depth 6 5 + Stroke 12 (mm) Stroke (mm) NS LT J LA LB 5 14 10 49 4 10 49 14 10 4 15 59 24 4 20 20 24 59 4 20 25 30 30 69 4 30 69 30 30 4 40 79 45 20 6 20 50 55 89 6 25 25 60 60 30 30 99
48 76.5 87.5 46 48 39.5 26 56.5 67.5 Note 1) Auto switches cannot be installed in Area C in the case of 15. 25, 32, 40, 50, 63 (mm) Auto switch model A B C D D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-Y5 D-Y7P D-Y7W D-A9 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 D-M9 D-F9W D-Z7 D-Z80 Bore size (mm) 25 32 40 50 63 18 21.5 23.5 27.5 29.5 99
129 118.5 108 97.5 87 76.5 66 55.5 364.5 354 343.5 333 322.5 312 301.5 291 280.5 270 259.5 249 238.5 228 217.5 207 196.5 186 175.5 165 VFR 387.5 375 375 362.5 350 337.5 325 312.5 300 300 287.5 275 262.5 250 237.5 237.5 225 212.5 200 187.5 398 385.5 385.5 373 360.5 348 335.5 323 310.5 310.5 298 285.5 273 260.5 248 248 235.5 223 210.5 198 VQ7 (L4) (L3) VV5QC21 (5.25) L2 L1 P = 16 38.5 1 1 99
89.5 49 74 39.5 64.5 49 74 39.5 64.5 27.5 27.5 15.5 124 124 25 25 114.5 114.5 24 99 89.5 49 74 39.5 64.5 49 74 39.5 64.5 30 30 15.5 D-B5 D-B6 D-B5 D-B6 125 125 32 32 115.5 115.5 25 100 90.5 50 75 40.5 65.5 50 75 40.5 65.5 33.5 33.5 15.5 129.5 129.5 40 40 117.5 117.5 29.5 104.5 92.5 54.5 79.5 42.5 67.5 54.5 79.5 42.5 67.5 38 38 19 20 20 25.5 100.5 91 50.5 75.5 41 66 50.5 75.5 41 66 27.5 27.5
Note 2) Only non-magnetic material is permitted as the mounting surface of a 20 cylinder. 25, 32, 40 (mm) Applicable switch model Bore size (mm) D-Z7/Z80/Y59/D-Y7P/Y7W A B C D 25 18 99 43 74 32 21.5 108.5 46.5 83.5 40 23.5 124.5 48.5 99.5 Note 1) 50 mm is the minimum stroke available with 2 auto switches mounted. Note 2) The above dimensions are given as reference dimensions.
Electric Actuators / Common Precautions . 98 15.1 Design and Selection . 98 15.2 Mounting . 99 -3No. JXC-OMU0026 15.3 Handling Precautions . 99 15.4 Operating environment . 101 15.5 Maintenance and Precautions . 101 15.6 Precautions for actuator with lock . 102 16.
D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 30 6 26 46 42 46 42 26 30 10 28 32 48 44 48 44 28 32 15 17.5 21.5 76.5 72.5 56.5 60.5 20 19.5 23.5 87.5 83.5 39.5 35.5 67.5 71.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25 to 63 A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 18 97 99
Symbol Size One-touch fittings 00 Same diameter tubing 99 Same diameter rod Tubing (rod) connection 04 4 06 6 08 8 10 10 12 12 16 16 Model Different dia. tubing (Plug-in reducer) Symbol Model Oval type Round type H Straight union v v Different diameter straight v v L Union elbow v v Plug-in elbow v v LU Branch union elbow v Accessories/Tube cap T Union tee v v Different diameter tee v v
Page 112 99 A Thermo-chiller Air-cooled 200 V Type Standard Type HRS100/150 Series RoHS How to Order 100 A 20 HRS Option Cooling capacity 100 10 kW 150 15 kW Cooling method Nil None A With caster adjuster-foot B With earth leakage breaker B1 With earth leakage breaker with handle K Note) With fluid fill port A Air-cooled refrigeration Pipe thread type Nil Rc F G (with Rc-G conversion fitting
With float type auto-drain With drain guide Port size A B C D E J K L M N F G H Model P IDG3M/3HM/5M/5HM IDG10M/10HM 157 201 226 150 146 56 87 196 162 158 99 1/8, 1/4 5.5 66.5 35 210 196 15 9 IDG20M/20HM 1/4, 3/8 205 201 66 130 209 13 12 223 209 IDG30M/30HM 162 158 87 6 78 40 20 303 IDG30LM 149 145 56 86 196 9 210 196 5.5 7 5.5 70 95 70 35 50 35 15 22 15 IDG50M/50HM 3/8 177 172 80 87 241
800 Bore size (mm) 20 25 32 40 W J K KA MM NA PG PH PL S TA TB TC WA WB WH WW XA XB P 30 M5 x 0.8 M4 x 0.7 depth 7 5 6 M8 x 1.25 24 M5 x 0.8 21.5 2 65 141 (149) 11 11 88 15 (16) 23 5.5 3 12 30 M6 x 0.75 M5 x 0.8 depth 7.5 5.5 8 M10 x 1.25 29 M5 x 0.8 26.5 2.5 73 151 (159) 11 11 98 15 (16) 25 6 3 12 25 M8 x 1.0 M5 x 0.8 depth 8 5.5 10 M10 x 1.25 35.5 Rc 1/8 26.5 2.5 73 154 (162) 11 10 (11) 99
Note 2) When compressor discharge concentration is 30 mg/Nm3 Polycarbonate Relief type Construction/Filter regulator Weight (kg) 0.63 0.97 1.99 1.91 Specifications Model
Address Setting Setting2 Address Node Address 8 10 1 0 0 0 (Default setting) 0 1 1 0 2 2 OFF : : : 9 8 98 9 9 99 0 0 100 0 1 101 ON : : : 2 5 125 : When the address is set to 0, or to 126 or over, it causes an error and turns on the [SF] and [BF] LEDs. -21No.EX-OMN0028-B V_SEL switch: A function to select the number of occupied valve outputs.
112 1/8 26 16 25 2 104 10 (13) 26 7 8 47 to 300 301 to 800 58.5 12 301 to 800 (mm) Bore size (mm) 20 25 32 40 P J K KA MM NA PG PH PL S TA TB TC WA WB WH WW W XA XB 141 (149) 88 5.5 M5 x 0.8 M4 x 0.7 depth 7 5 6 M8 x 1.25 24 M5 x 0.8 21.5 2 65 11 11 15 (16) 23 30 3 12 151 (159) M6 x 0.75 98 6 5.5 8 M10 x 1.25 29 M5 x 0.8 26.5 2.5 73 11 11 15 (16) 25 30 3 12 M5 x 0.8 depth 7.5 154 (162) 99
.: 10 (NPT threads: 3/8 inch) Width across flats 19 With float type auto drain With drain guide Port size A B C D E F G H J K L M N Model P 150 146 56 87 196 162 158 99 157 201 226 IDG3M, 3HM, 5M, 5HM IDG10M, 10HM 1/8, 1/4 9 210 196 5.5 66.5 35 15 IDG20M, 20HM 1/4, 3/8 205 201 66 130 209 13 12 223 209 IDG30M, 30HM 162 158 87 6 78 40 20 303 IDG30LM 149 145 56 86 196 9 210 196 5.5 7 5.5 70
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 300 (Lead wire length) 2-C6, C8 A 2 B 10.7 31.5 (Port size: One-touch fitting type) Plug connector (K) Plug connector (L) 3 postion 157 Double 149.5 3 position 172.2 Double 165 Single 114.5 300 (Lead wire length) Single 99 300 (Lead wire length) With
Formula: L5 = 19n + 11 L3 = 19n + 23 n: Stations (Max. 20 stations) Dimensions L n 2 3 110.5 100 80 15.5 68 4 135.5 125 99 18.5 87 5 148 137.5 118 15 106 6 173 162.5 137 18 125 7 198 187.5 156 21 144 8 210.5 200 175 18 163 9 235.5 225 194 21 182 10 248 237.5 213 17.5 201 11 273 262.5 232 20.5 220 12 285.5 275 251 17.5 239 13 310.5 300 270 20.5 258 14 323 312.5 289 17 277 15 348 337.5 308