SMC Corporation of America
Elite Part Number Search
Search Results "CKZT50-120-DCN017AN"

The SFB20, with a sintered metallic element, has a nominal filtration of 120 micron.  The SF series can be used under different environments with chemical resistant and heat resistant materials (refer to catalog specifications for each series).    Max. Flow Capacity: 200l/min (ANR); Noise reduction: 30 dB (A); Class 4, ISO14644-1; RoHS compliant

Compiles with NAAMS standard (CKZ5N); 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; Easier mechanism unlocking; Space-saving and lightwieght; High clamping force

The SFB20, with a sintered metallic element, has a nominal filtration of 120 micron.  The SF series can be used under different environments with chemical resistant and heat resistant materials (refer to catalog specifications for each series).    Max. Flow Capacity: 200l/min (ANR); Noise reduction: 30 dB (A); Class 4, ISO14644-1; RoHS compliant

Compiles with NAAMS standard (CKZ5N); 9 opening angles: 15, 30, 45, 60, 75, 90, 105, 120, 135; Easier mechanism unlocking; Space-saving and lightwieght; High clamping force

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Piston Material: Stainless Steel, Added Function: N/A, Rod Motion: Double Acting Single Rod, Tube Material: Stainless Steel, Piston Packing Material: NBR, Stroke(mm): 120, Cushioning Mechanism: N/A, Support Type: -, Standard: ISO Specifications, Nominal Pressure: 16MPa, Cylinder Type: Retainer Pin/Stopper Set, Cylinder Nominal Designation Size(φ): 40, Port thread type: NPT, Rod Tip Shape:

Piston Material: Stainless Steel, Added Function: N/A, Rod Motion: Double Acting Single Rod, Tube Material: Stainless Steel, Piston Packing Material: NBR, Stroke(mm): 120, Cushioning Mechanism: N/A, Support Type: -, Standard: ISO Specifications, Nominal Pressure: 16MPa, Cylinder Type: Retainer Pin/Stopper Set, Cylinder Nominal Designation Size(φ): 40, Port thread type: NPT, Rod Tip Shape:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 120, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number