SMC Corporation of America
Elite Part Number Search
Search Results "ZH13DSA-01-02-02N"

Type 31 How to Order Applicable solenoid valve Note) SY113--M3 SY113A--M3 SY123--M3 SY123A--M3 Applicable blanking plate assembly SY100-77-1A SS3Y1 31 05 Stations 02 2 stations P R 20 20 stations R port M5 x 0.8 P port M5 x 0.8 Note) SY113(A) and SY123(A) cannot be mounted on the same manifold.

VQZ Model Weight Weight (g) VFN200N/Flow Characteristics VZ Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN212N-5D-02F 240 380 VS C 2.68 2.68 b 0.40 0.40 Cv 0.72 0.72 C 5.41 5.41 b 0.31 0.31 Cv 1.38 1.38 VFN212N-5D-02F-D 2 position Single solenoid VFN Double solenoid How to Order VFN212 5 D N 02 F Z NAMUR Interface Solenoid Voltage Nil D Single solenoid Double solenoid Thread

Auto Feed Lube Port size Description Applicable model Symbol Nil 02 03 04 06 10 12 14 20 4 1 With bracket ALF400 to 600 B 8 3 Body size 2 1 F.R.L. 40 50 60 80 90 2 1 4 3 4 3 1 AV 1 1 1 4 1 2 1 1 2 2 1 Line pressure (MPa) AU 2 Thread type AF Nil N F Rc NPT G AR Note 1) Tank pressure is removed when line pressure is stopped.

Cylinder bore size Applicable bore size Fitting type Connection thread Model KJ23-M3 KJ04-M3 KJ23-M5 KJ04-M5 KJ06-M5 3.2 M3 x 0.5 4 4 One-touch fitting 3.2 6 10 15 M5 x 0.8 4 6 Recommended Speed Controller Applicable bore size (mm) Connection thread Elbow type meter-in Universal type meter-in In-line type meter-in AS1211F-M3-02 M3 AS1001F-02 2 AS1211F-M5-02 M5 AS1211F-M3-23 AS1311F-M3-23

For Water 30 20 VX2 60-02 10 VX234.5 VX2 46 VX2 6010 VX2 50 8 3 2 04 03 3 2 3 2 VX223 10 3 2 VX2112 5 4 3 Flow rate Q l/min 2 1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.001 (0.0018) (0.0054) 0.01 (0.017) 0.05 (0.07) 0.1 Pressure differential P = (P1 P2)

List part numbers of the installed valve and option in required station location separately under manifold part number. 2.1-10 Series SY100 Common SUP/Common EXH 30 Type How to Order Applicable solenoid valve (1) SS3Y1 30 05 F SY113-l-M3 SY113A-l-M3 Stations 02 Applicable blank plate assembly 2 stations ... ...

Location and size A, B port 02 Side 1/4 03 Side 3/8 04 Side 1/2 06 Side 3/4 10 Side 1 02B Bottom 1/4 03B Bottom 3/8 04B Bottom 1/2 Size of P, EA, EB port 02 1/4 03 3/8 04 1/2 06 3/4 10 1 Option No option TBU With terminal box SU With SI unit W Splash proof DISTRIBUTED BY: NATIONAL AND WORLDWIDE SERVICE NETWORK FOR A BRANCH OFFICE NEAR YOU, CALL United States Branch Offices Oceania SMC Corporation

ZPT U N 02 B4 ZP U N 04 X11 Dia. (mm) Vacuum entry (Mounting thread diameter) Dia. (mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.

Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.

Applicable solenoid valve Type 20 How to Order G L M D Option VV4Z1 05 20 1 4(A), 2(B) port VZ1120-M5 Applicable blanking plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A Stations P, R port thread type 02 2 stations F: With foot bracket 20 20 stations Nil Rc G NPT 1(P) port 00F 00N 3(R) port NPTF 00T Bracket is not mounted

Type 31 How to Order Applicable solenoid valve Note) SY113--M3 SY113A--M3 SY123--M3 SY123A--M3 Applicable blanking plate assembly SY100-77-1A SYJ SS3Y1 31 05 VK Stations VZ 02 2 stations P R 20 VT 20 stations R port VP M5 x 0.8 P port M5 x 0.8 VG Note) SY113(A) and SY123(A) cannot be mounted on the same manifold.

Applicable solenoid valve Type 20 How to Order G L M D Option VV4Z1 05 20 1 4(A), 2(B) port VZ1120-M5 Applicable blanking plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A Stations P, R port thread type 02 2 stations F: With foot bracket 20 20 stations Nil Rc G NPT 1(P) port 00F 00N 3(R) port NPTF 00T Bracket is not mounted

For positive pressure 80 ISE 02 N M For vacuum/ compound pressure M 80 ZSE 02 N Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English

Number of stations 02 2 stations Port size (OUT side) Symbol Port size 02 03 1/4 3/8 Applicable model ARM2500 ARM3000 10 10 stations Thread type Nil Rc F N G NPT Piping ARM3000 Symbol A B IN From end plate From OUT port or G port Type Common IN Individual IN Standard Specifications Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Regulating pressure range 0.05 to 0.85 MPa ARM2500

Pressure gauge Pressure gauge Port size Applicable series Symbol Port size VBA10A-02 02 03 04 VBA1A VBA2A VBA4A 1/4 3/8 1/2 VBA11A-02 Elbow silencer Silencer Combination of Thread Type and Options VBA20A-03 Body size Option Semi-standard Thread type Nil S GN N GS G Nil GLS -Z LN LS GLN Nil F N T Nil F N T Nil F N T 10A 11A VBA22A-03 20A 22A 40A 42A 43A VBA40A-04 Air Tank Compatibility Chart

Refer to page 643 for replacement method. 02 1/4 03 3/8 Nil Rc N NPT T NPTF F G Note) For bottom ported, port size is 1/4 only. 611

Flow rate range) Note 1) Certificate in both English and Japanese Made to Order 2 to 200 L/min 201 Flow adjustment valve Unit specifications Nil None M SI unit only Note 2) S Yes Nil Unit selection function Note 3) Note 2) Fixed unit: Instantaneous flow: L/min Port size Accumulated flow: L C8 8 (5/16") One-touch fitting Note 3) Since the unit for Japan is fixed to SI due to new measurement 02

IDX-OM-X004-D PRODUCT NAME Heatless Air Dryer MODEL / Series ID20-02 ID30-04 ID40-04 ID60 -06 Please read this manual prior of using the air dryer. Keep the manual readily available for reference. To Customers Thanks for purchasing SMC Heatless Air Dryer. This opertion manual must be read and understood throughoutly before handling.