No.SFOD-OMO0004-B PRODUCT NAME Electrostatic Sensor Monitor MODEL/ Series IZE11 Table of Contents Safety Instructions 2 Model Identification and How to Order 7 Summary of Product parts 8 Mounting and Installation 10 Installation 10 Wiring 11 Setting 14 Measurement mode 15 Function selection mode 18 Default setting 18 F0 Select connect sensor 19 F1 Operation of OUT1 20 F2 Operation of OUT2
Name Material Remark 1 Body A PBT 2 Body B Brass Electroless nickel plating 3 Handle POM 4 Needle POM 5 End cover Brass Electroless nickel plating 6 Spring Steel wire 7 U-seal HNBR 8 O-ring NBR 9 Needle O-ring NBR 10 Y seal NBR 11 Seal for fitting NBR 12 Cassette 16 Seal NBR For G thread only. 11 - Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249
[January 2021] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2010-2021 SMC Corporation All Rights Reserved No.EX-OMO0007-E
If any of the troubleshooting is not applicable, please contact your SMC sales representative. 8 Dimensions -12- Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2011 SMC Corporation
Space to wiring a proximity switch Space to perform a manual lock release Space 14 - To change the arm opening angle 7 1. Procedure for changing the stopper bolt position 1) Remove the stopper bolt of the head cover, and replace with a stopper bolt for the desired angle using the tightening torque below. When tightening the stopper bolt, hold the head cover.
ZL-OM00801 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com This manual is subject to change without prior notice. 2010 SMC Corporation All Rights Reserved 31 -
appropriate model Coil breakage due to Replace the coil Assy mishandling of surge Foreign matter Eliminate the foreign matter/ Install a filter Coil burning High voltage Adjust voltage(Rated voltage 10%V) High fluid/ambient temp Select the appropriate model Water splashes over for a long time Take waterproofing measures Large vibration/impact Vibration isolation/ Change installation site 14
. -3No.VQ7-6-OMW0001 4 No.VQ7-6-OMW0001 5 No.VQ7-6-OMW0001 6 No.VQ7-6-OMW0001 7 No.VQ7-6-OMW0001 8 No.VQ7-6-OMW0001 9 No.VQ7-6-OMW0001 10 No.VQ7-6-OMW0001 11 No.VQ7-6-OMW0001 12 No.VQ7-6-OMW0001 13 No.VQ7-6-OMW0001 14 No.VQ7-6-OMW0001 15 No.VQ7-6-OMW0001 16 No.VQ7-6-OMW0001 17 No.VQ7-6-OMW0001 18 No.VQ7-6-OMW0001 19 No.VQ7-6-OMW0001 20 No.VQ7-6-OMW0001 21 No.VQ7-6-OMW0001 22 No.VQ7-6-OMW0001
(displayed alternately) Press S-key. displayed alternately 14 - Press and keys for 3 seconds or more. (press S-key to ) is displayed "Initialize" is executed, after 5 seconds. (Release keys till less than 5 seconds to ) Turning off for 1 second Returns to the state immediately after turning on the power supply.
Recommended tightening torque [N-m] Piping Warnin Warnin Warnin Warning g g g Thread 1/4 Torque 12 to 14 Do not apply any additional twisting, or bending moments except for the weight of the filter regulator itself. Provide separate support for external piping, as damage may otherwise occur.
Width across torque (Nm) flats AS1002F-02 0.07 4.5 Installation AS1002F 0.2 7 AS2002F 0.3 9 Warning AS2052F 1 12 (1) Operation Manual AS3002F 2 14 Install and operate only after reading the operation manual carefully and understanding the contents. Keep the manual where is can be referred to if necessary.
Recommended tightening torque [N-m] Thread 1/4 Piping Warning Torque 12 to 14 Do not apply any additional twisting, or bending moments except for the weight of the filter regulator itself. Provide separate support for external piping, as damage may otherwise occur.
SeriesNCA1 Air Cylinder: Standard Type Double Acting, Single Rod Maintenance Parts 150 to 400 Construction 15 17 13 14 16 Seal Kit Parts List No. 13 14 15 16 17 Description Cushion Seal Rod Seal Piston Seal Cushion Valve Seal Cylinder Tube Gasket Material NBR NBR NBR NBR NBR Kit no.s can be found on the next two pages. *Call or email us at sales@smcpneumatics.com for request.
NCQ8B200-PS NCQ8B200-PS 200 (2") NCQ8B250-PS NCQ8B250-PS 250 (2 1/2") NCQ8B300-PS NCQ8B300-PS 300 (3") NCQ8B400-PS NCQ8B400-PS 400 (4") Construction Double Acting, Double Rod SeriesNCQ8W 15 13 14 Seal Kit Parts List No. 13 14 15 Description Piston Seal Rod Seal Tube Gasket Material NBR NBR NBR Repair Parts: Standard Seal Kit for Double Acting, Double Rod Remarks Bore size Kit no.
27 24 5 19 14.5 11.5 15 10 5 25 19 M22 X 1.5 20.5 4.5 17.5 15 31.5 27 24 Panel Mounting Style CJPB B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14
Model L5 D3 T2 13.7 18.7 16.8 18.7 18.7 20.8 20.8 21.8 34.6 33.9 11.8 39.6 38.9 22.9 28.2 25.2 28.2 28.2 32.6 32.6 34.4 11.6 15.2 12.8 15.2 15.2 18.5 18.5 20.9 38.4 44.7 43.4 46.4 51.3 54.1 64.2 66 14 15.8 18 19.7 20.3 23.1 32 35 65 68 107 110 212 215 6 8 6 8 8 10 10 12 ASP330F-01-06S ASP330F-01-08S ASP430F-02-06S ASP430F-02-08S ASP530F-03-08S ASP530F-03-10S ASP630F-04-10S ASP630F-04-12S
Bore size Applicable series 02 03 04 06 10 12 14 20 Note 1) AS800 is available as special.
14 9.6 4.3 9.5 TMH-12 TMH-13 15-9-13
D90 reverse unit Air gripper for auto hand changing system 20Variations Adapter for assembling robot Series MA2 8, 10, 11, 14, 15, 20 Series MA3 10, 11, 14, 15, 20, 24, 25 Additional installation unit of electrical contact point (Able to add 8 contact points) Air grippers for auto hand changing system (10 to 20) Standard type Narrow type 90 reverse unit Added to the standard AHC unit By attaching
Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to the home position.