SMC Corporation of America
Elite Part Number Search
Search Results "MHKL2-20C"

capacity (cm3) 7 25 55 135 135 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) Ambient and fluid temperature 5 to 60C (with no freezing) Bowl material Polycarbonate Bowl guard Option Standard Weight (kg) 0.07 0.20 0.24 0.47 0.52 1.06 1.13 Notes 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

(Coil temperature: 20C, at rated voltage) (B) 2 (A) 4 Weight SOL.b SOL.a 3 (EB) 5 (EA) Weight (g) Series Type of actuation 1 (P) 66 Single solenoid 4 position dual 3 port valve: N.O.

capacity (cm3) 55 135 7 25 135 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (With no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Option Standard Weight (kg) 0.47 0.24 1.13 0.07 0.20 0.52 1.06 Note 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

W (due to an increase in the heat generation of the pump) Note 1) -MT: Applicable to deionized water piping + High pressure pump Note 2) The capacity at the thermo-chiller outlet when the circulating fluid temperature is 20C. Note 3) Required minimum flow rate for cooling capacity or maintaining the temperature stability. Note 4) Cooling capacity will decrease as pump power increases.

Local Area: (800) 258-9200-www.stevenengineering.com Maximum response frequency 500Hz Indicator light Red LED (lights up when ON) Ambient temperature 10 to 55C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C

response frequency Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light Ambient temperature 10 to 55C 25 to 70C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C

4 15 1/4: 30 3/8: 40 Oil capacity [cm3] 7 25 55 135 Recommended lubricant Class 1 turbine oil (ISO VG32) Bowl material Polycarbonate Bowl guard Semi-standard (Steel) Standard (Polycarbonate) Weight [kg] 0.07 0.10 0.20 0.38 0.43 0.94 1.09 *1 The flow rate is 5 drops or greater/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

Voltage for 20C-114 POTTED (Type P)Class F rated at 105IEEE* and 110 C. Continuous & 125 C. IntermittentU.L.** Coast Rating*** 125 Continuous. The unit is water proof. *IEEE*The temperatures listed are the limiting temperature definitions by this organization for insulation material categories. Therefore, a 2C-115 coil should be used with a field Voltage of 130 volts 60 cycles.

Specifications Applicable tubing material Nylon Soft nylon 4/2.5 3.18/2, 4/2.5 Polyurethane M3 Applicable tubing 4/2.5 6/4 3.18/2.18 4/2.5 6/4 3.18/2 4/2.5, 6/4 1 8 M5-R Line up various styles For air connection in confined areas. 1.5 MPa 1.0 MPa 0.8 MPa Max. operating pressure (at 20C) 1 8 M3, M5, R Connection size JIS B 0209 Class 2 (Metric coarse thread), JIS B 0203 (Taper pipe thread

Operating temp. range Operating humidity range [%RH] Motor size Motor type Motor type S2, S3: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7: Absolute 18-bit encoder (Resolution: 262144 p/rev) Encoder Type Note 7) 29.4 57.3 6.3 109 35.3 Non-magnetizing operation type 69.2 7.9 specifications Holding force [lbf] 132.3 44.3 86.6 7.9 165.5 Power consumption [W] at 68F (20C

Rod Boot Material Max. ambient temperature Symbol Rod boot material J 20C Nylon tarpaulin 110C K Heat resistant tarpaulin Maximum ambient temperature for the rod boot itself.

Voltage for 20C-114 POTTED (Type P)Class F rated at 105IEEE* and 110 C. Continuous & 125 C. IntermittentU.L.** Peter Paul Rating*** 125 Continuous. The unit is water proof. *IEEE*The temperatures listed are the limiting temperature definitions by this organization for insulation material categories. Therefore, a 2C-115 coil should be used with a field Voltage of 130 volts 60 cycles.

FGH Series EJ Specifications EJS-013 EJS-006 EJS-004 Model EJS-002 Filtration accuracy(Filtration efficiency 99%) 13 6 4 2 2490 2090 2310 1890 117 mm Length Filtration area (cm2) 5600 4700 5200 4250 246 mm 11200 9400 10400 8500 496 mm Heat resistant temperature (C) 80 Filter media Polyester Material Reinforcement material Polypropylene Others Polypropylene Pressure resistance 0.5 MPa at 20C

-X Body option Nil M Standard (Rod end female thread) Rod end male thread Cushion 20C Rubber bumper Piping Data Action Screw-in piping Built-in One-touch fittings Note) Nil F D Double acting Note) Bore sizes available w/ One-touch fittings are 32 to 63. Cylinder stroke (mm) Refer to Standard Stroke on page 7-6-122.

(coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.

Drive Method Sine-wave current drive with PWM control of IGBT Feedback Encoder: 20-bit (absolute) Surrounding Air Temperature 0C to +55C Storage Temperature -20C to +85C Ambient Humidity 90% RH or less With no freezing or condensation Storage Humidity 90% RH or less Vibration Resistance 4.9 m/s2 Shock Resistance 19.6 m/s2 Operating Conditions IP10 An environment that satisfies the following

Local Area: (800) 258-9200-www.stevenengineering.com Maximum response frequency 500Hz Indicator light Red LED (lights up when ON) Ambient temperature 10 to 55C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C

Drive Method Sine-wave current drive with PWM control of IGBT Feedback Encoder: 20-bit (absolute) Surrounding Air Temperature 0C to +55C Storage Temperature -20C to +85C Ambient Humidity 90% RH or less With no freezing or condensation Storage Humidity 90% RH or less Vibration Resistance 4.9 m/s2 Shock Resistance 19.6 m/s2 Operating Conditions IP10 An environment that satisfies the following

response frequency Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light Ambient temperature 10 to 55C 25 to 70C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C

DStroke range: 51 to 599 mm MY2 X168 Bore size Stroke Auto switch Symbol Bore size Stroke Auto switch Symbol MY2 XB10 -X Series/Bore size 16 25 40 20C H HT Cam follower guide type High precision guide type (Single axis) High precision guide type (Double axis) Series/Bore size 16 25 40 H HT High precision guide type (Single axis) High precision guide type (Double axis) Data (Example) MY2H40G