Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
In case of SJ3l60T, electric waveform of energy saving type 24 VDC Applied voltage 0 Standard products 0.4 W Indicator light A side: Orange B side: Green With power saving circuit 0.15 W Solenoid a 0 W Solenoid b 67 ms Changing the Connector Entry Direction When a power saving circuit is installed, a diode to prevent reverse current is not available for 12 V DC spec.
HRX-OM-M091-P Operation Manual Communication function Thermo chiller Air-Cooled Water-Cooled refrigerated type refrigerated type HRS012-A-10HRS012-W-10HRS018-A-10HRS018-W-10HRS012-A-20HRS012-W-20HRS018-A-20HRS018-W-20HRS024-A-20HRS024-W-20HRS030-A-20HRS030-W-20HRS040-A-20 HRS040-W-20HRS050-A-20HRS050-W-20HRS060-A-20HRS060-W-20Keep this manual available whenever necessary 2022 SMC CORPORATION
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
Tap Water (as a Circulating Fluid) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Item Unit Standard value Influence Corrosion Scale generation Voltage pH (at 25C) 6.0 to 8.0 v v Electric conductivity (25C) [mS/cm] 100*1 to 300*1 v v Chloride ion (Cl) [mg/L] 50 or less v Sulfuric acid
ON/OFF, with load (ON:OFF=3:1)W A variety of single/double modular configurations is possible.
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
q w q w q SL5802S e q FV4 FV4 FV4 FV4 w FV4 FV4 FV4 FV4 r 2PW 3PW 3PW 4PW 0 V3 V3 MPA MPA 2PW 3PW 4PW 1 1) Other range available.
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L Reed D-A90(V), D-A93(V), D-A96(V)
circuit 0.35 (With light: 0.4) Power consumption (W) DC 0.1 (With light only) External pilot 1.4 (With light: 1.5) 100 V 110 V [115 V] 200 V SYJ31 R 2 4 SYJ32 R 2 4 1.6 (With light: 1.7) [1.7 (With light: 1.8)] (A) 2 (A) 2 Apparent power (VA) AC X X 2.3 (With light: 2.4) 220 V [230 V] 2.5 (With light: 2.6) [2.7 (With light: 2.8)] 1 (P) 3 (R) 1 (P) 3 (R) Surge voltage suppressor Indicator
Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator
HRX-OM-S004-N Operation Manual InstallationOperation Original Instructions Thermo chiller HRS100-A-20HRS150-A-20HRS100-A-40HRS150-A-40HRS100-A-46HRS150-A-46HRS100-W-20HRS150-W-20HRS100-W-40HRS150-W-40HRS100-W-46HRS150-W-46Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To the users Thank you for purchasing SMCs Thermo chiller (hereinafter referred to
Back up spring Poppet spring Note Platinum silver De-energized De-energized q w e Stainless steel r Replacement Parts Part no. No.
drawing shows HRS090-W-20.)
switch 12 V Relay, PLC Grommet 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V 3-wire (NPN equivalent) IC circuit A96V A96 5 V Grommet A93V A90V A93 A90 Relay, PLC 100 V 2-wire 24 V 12 V No IC circuit 100 V or less Refer to pages 796 and 797 for the details on auto switches with a prewired connector.