Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: 0 (w/o SI Unit), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: B4 (ø4 One-touch Fitting, Downward Elbow)
SERIES DIRECTIOIIAL AIR VALVE AIR PILOT OPERATED NVSA NVSA 41.B4 SPECIHCANONS cfiAnaqTEitsnca A 4 C 4 NV )34 44 44 tca 1r/l ,|5!r q, <ng on Subpletslr 1/il' 38. 1E' 1.17 1.47 1.47 1.47 '1.47 l.6r t.61 1.61 1,0i 1.61 2.39 2.39 2.39 2.N 2.39 2.72 2.72 272 272 3.78 3.7! 3.78 3_78 3.7E Nt/sA 4t 04 spoor 5lrof6: In.
C4 C6 M5 L4 L6 B4 B6 4 One-touch fitting 6 One-touch fitting The "" symbol indicates mounting. Put the "" symbol at the beginning of part numbers for solenoid valves, etc., which are to be mounted. M5 x 0.5 4 elbow fitting assembly (upward) Valve stations are numbered from station 1 on the D side.
Series: SS5Y3 (SY3000 Manifold), Model: 10 (Side-Ported), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 16 Stations, P,E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A,B Port Size: B4 (ø4 One-touch Fitting), Downward Elbow
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 10 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: B4 (ø4 One-touch Fitting, Downward Elbow), Mounting: AA (Direct Mounting, Name Plate w/Station
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 11 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: B4 (ø4 One-touch Fitting, Downward Elbow), Mounting: AA (Direct Mounting, Name Plate w/Station
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 12 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: B4 (ø4 One-touch Fitting, Downward Elbow), Mounting: AA (Direct Mounting, Name Plate w/Station
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: VB (CC-Link - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 08 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: B4 (ø4 One-touch Fitting, Downward Elbow), Mounting: D (DIN Rail Mounting w/o Name Plate, w/o Station
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: VB (CC-Link - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 08 Stations, P, E Port Location: D (D Side), SUP/EXH Block: Internal Pilot, A, B Port Size: B4 (ø4 One-touch Fitting, Downward Elbow), Mounting: D (DIN Rail Mounting w/o Name Plate, w/o Station Number
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: VB (CC-Link - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 08 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: B4 (ø4 One-touch Fitting, Downward Elbow), Mounting: D (DIN Rail Mounting w/o Name
Model: 10S4 (Side-Ported, Serial Interface), SI Unit Specification: V (CC-Link), Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assembly: S (Internal Pilot/Built-in Silencer), A,B Port Size: B4 (ø4 One-touch Fitting), Downward Elbow
B4 Yellow Maintenance detection signal OUT (Contact point A) Turns ON when emitter needs cleaning. A5 Purple Error signal OUT (Contact point B) Turns OFF when power supply failure, ion discharge error, connected sensor failure, or CPU operation failure. (ON when there is no problem.)
B4 Yellow Maintenance signal OUT (A contact) A1 A5 Turns OFF if power supply failure, incorrect high voltage, fan motor failure, CPU failure, excess current on the output circuit, emitter cartridge mounting failure, or automatic cleaning failure (for product with automatic cleaning function) is detected.
B4 Yellow Maintenance detection signal OUT(Contact point A) Turns ON when electrode needs cleaning. Turns OFF when power supply failure, ion discharge error, connected sensor failure, or CPU operation failure. (ON when there is no problem.) A5 Purple Error signal OUT(Contact point B) B5 White Unused Confirm the power supply cable dimensions on page 434 for the cable specifications.
Pad Type: Related Components, Compatible pad diameter(mm): ø2 to ø8, 2 × 4, 3.5 × 7, 4 × 10, ø10 to ø16 (thin-type series), Compatible Model: ZPT▲▲□**B4
Pad Type: Related Components, Compatible pad diameter(mm): ø2 to ø8, 2 × 4, 3.5 × 7, 4 × 10, ø10 to ø16 (thin type series), Compatible Model: ZPY▲▲□**-N4-B4
Pad Type: Related Components, Compatible pad diameter(mm): ø2 to ø8, 2 × 4, 3.5 × 7, 4 × 10, ø10 to ø16 (thin type series), Compatible Model: ZPY▲▲□**-N6-B4
Pad Type: Related Components, Compatible pad diameter(mm): ø2 to ø8, 2 × 4, 3.5 × 7, 4 × 10, ø10 to ø16 (thin type series), Compatible Model: ZPY▲▲□**-U6-B4
Pad Type: Related Components, Compatible pad diameter(mm): ø2 to ø8, 2 × 4, 3.5 × 7, 4 × 10, ø10 to ø16, Compatible Model: ZPR▲▲□**-04-B4
Pad Type: Related Components, Compatible pad diameter(mm): ø2 to ø8, 2 × 4, 3.5 × 7, 4 × 10, ø10 to ø16, Compatible Model: ZPR▲▲□**-06-B4