The level of the fluid in external piping must be under a sub tank capacity. HRZD Series 8.1 Specification 8-1 HRX-OM-M005 Chapter 8 Appendix *9: This value will be needed to when temperature will be going down.
Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 Weight (g) KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 43 43 61 61 94 94 84 84 117 117 183 183 O.D.
Be sure to mount a seal cap on any unused I/O connectors. Otherwise, the specified enclosure cannot be maintained. The signal name of I/O device and each Unit address can be entered and mounted on each Unit.
Before mounting, please be sure to confirm the types of units that can be connected.
Please take note that warranted repair shall not be available if these preconditions are disregarded. (1) System operation shall be conducted by following operating procedure defined in the Operation Manual. (2) Daily and periodic inspections designated in the Operation Manual shall be made as scheduled. (3) Inspection record shall be entered in the Daily Inspection Sheet provided in the
OFF/Hold can be set output of all. Via switch 1 Hold/Clear priority setting Setting by CoE object or the Web server becomes valid. OFF/Hold/Forced ON can be set per channel. Via software The data format of all analogue units is assumed to be LSB-MSB.
To use the lock for drop prevention purposes, the load to be attached to the cylinder must be within 35% of the cylinders holding force.
To use the lock for drop prevention purposes, the load to be attached to the cylinder must be within 35% of the cylinders holding force.
damaged and gasket may be deformed.
Note 2) The pressure must be the P port pressure or less.
damaged and gasket may be deformed.
/Cap (Resin part only) RBC C 08 Applicable model 08 10 14 20 27 RBC2015 RBC2725 RBC0805, 0806 RBC1006, 1007 RBC1411, 1412 Cap Cap cannot be mounted for basic type. Please place an order with cap type from the beginning.
/Cap (Resin part only) RBC C 08 Applicable model 08 10 14 20 27 RBC2015 RBC2725 RBC0805, 0806 RBC1006, 1007 RBC1411, 1412 Cap Cap cannot be mounted for basic type. Please place an order with cap type from the beginning.
damaged and gasket may be deformed.
options Mounting brackets can be combined according to the operating conditions.
If it is not turned, it can be used in the same way as the nonlocking push type.
The instruction manual should be carefully read and fully understood before the product is installed and operated. Also, the manual should be kept where it can be easily referred to at any time. 2. Allow space for maintenance. Allow the space necessary for maintenance and inspections. 3. Tighten screws with the proper tightening torque.