Size: 7 [ø50(ø33)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: B (FKM Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 50F (2B Flange), Voltage: 2 (200VAC 50/60HZ), Lead Wire: G (Grommet)
Size: 7 (ø50), Valve Type: 0 [NC (Operating Pressure 1MPa)], Body Material: S (Stainless Steel Body), Thread: Rc(PT), Port Size: 50F (2B Flange)
XLA-40 SPECIAL KIT, HIGH VACUUM VALVE
Size: 7 [ø50(ø33)], Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: B (FKM Seal), Body Material: Standard, Pilot System Option: Standard, Thread: N (NPT), Port Size: 50F (2B Flange), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)
Size: 7 [ø50(ø33)], Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: A (NBR Seal), Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 50F (2B Flange), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)
BONNET ASSEMBLY FOR XLA-160A, HIGH VACUUM VALVE, L45, 10.38 lb
VALVE SEAL, XLA, R3 MATERIAL, HIGH VACUUM VALVE, L45, 5 lb
VALVE SEAL, XLA 80, R1 MATERIAL, HIGH VACUUM VALVE, L45, 6.71000 lb
VALVE SEAL, XLA 80, Q1 MATERIAL, HIGH VACUUM VALVE, L45, 6.71 lb
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 16, Seal Type: Bellows Seal, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150°C
Switch Part Number: No auto-switch (no magnet), Number Of Switches: -, Seal Material: EPDM (Formula No.: 2101-80), Body Surface Treatment: External: hard anodized aluminum, Internal: base material, Seal Change Location: Valve seal 1 / valve seal 2 / external seal, Length of Lead Wire for Switch(m): -
for 120℃), Switch Part Number: No auto-switch (no magnet), Number Of Switches: -, Seal Material: Kalrez (Formula No.: 4079), Body Surface Treatment: External: hard anodized aluminum, Internal: base material, Seal Change Location: Valve seal 1 / valve seal 2 / external seal, Length of Lead Wire for Switch(m): -
Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, with 120°C Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: 2-
40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, with 120°C Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: R1 [CHEMRAZ® (SS592)], Seal Replacement: 2-
25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, No Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: FKM, Same Specs as Standard FKM, Seal Replacement: 2-
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: FKM, Same Specs as Standard FKM, Seal Replacement: 2-
Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, with 120°C Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: 2-
Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Left Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: FKM, Same Specs as Standard FKM, Seal Replacement: 2-
40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, No Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: FKM, Same Specs as Standard FKM, Seal Replacement: 2-
16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 150°C, No Heater, Version: Refresh, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Body Surface Treatment: External: Hard Anodized - Internal: Raw Material, Seal Material: FKM, Same Specs as Standard FKM, Seal Replacement: 2-