Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, EXTERIOR SEAL, XLA 80, R1 MATERIAL, HIGH VACUUM VALVE, L45, 11.40000 lb

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, XLA, EXTERNAL SEAL, R3 MAT'L, HIGH VACUUM VALVE, L45, 0.265 lb

), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: R1 [CHEMRAZ® (SS592)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Indicator, Flange Side, Temperature: 5 to 150°C, with 100°C at 100VAC, 120°C at 200VAC Heater, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: R2 [CHEMRAZ® (SS630)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: P1 [BARREL PERFLUORO® (70W)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: R3 [CHEMRAZ® (SSE38)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: R1 [CHEMRAZ® (SS592)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA

Rear Flange Surface, Temperature: 5 to 150°C, No Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA

Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA