Flange Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m, Number: 1pc, Valve Open, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 1m, Number: 2pcs, Valve Open/Closed, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 1pc, Valve Open, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Indicator: With indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60℃ (no heater
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Indicator: With indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60℃ (no heater
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Indicator: With indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60℃ (no heater
Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: M9//--(w/o Auto Switch and w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic
Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: M9//--(w/o Auto Switch and w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: R2 [CHEMRAZ® (SS630)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: R1 [CHEMRAZ® (SS592)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, EXTERIOR SEAL FOR XLA, VACUUM SERIES, XLS NO SIZE RATING, .05557 lb
Please contact us for the latest version.sales@ocaire.com, EXTERNAL O RING FOR XLAQ-25, VACUUM SERIES, XLA NO SIZE RATING, 2.05326 lb
Please contact us for the latest version.sales@ocaire.com, EXTERNAL O RING FOR XLAQ-40, VACUUM SERIES, XLA NO SIZE RATING, .34393 lb
Please contact us for the latest version.sales@ocaire.com, EXTERNAL O-RING FOR XLAQ-25, VACUUM SERIES, XLA NO SIZE RATING, 2.05326 lb
Please contact us for the latest version.sales@ocaire.com, EXTERNAL O-RING FOR XLAQ-25, VACUUM SERIES, XLA NO SIZE RATING, 2.05326 lb
Please contact us for the latest version.sales@ocaire.com, EXTERNAL O-RING FOR XLAQ-40, VACUUM SERIES, XLA NO SIZE RATING, .34393 lb
Please contact us for the latest version.sales@ocaire.com, EXTERNAL O-RING FOR XLAQ-40, VACUUM SERIES, XLA NO SIZE RATING, .34393 lb
XLA XL XLQ XLQ y Body surface treatment/Seal material and its changed part Bodysurfacetreatment Part numbers indicating changed seal material and leakage XM XY Surface treatment External: Hard anodized Internal: Raw material External: Hard anodized Internal: Oxalic acid anodized Symbol Nil A Note 2) Leakage Pam3/s or less Note 1) Changed part None w, e w e Symbol External 1.3 x 10-10 (FKM
flange surface Right flange surface Left flange surface Right flange surface Flange side Flange side Left flange surface Rear flange surface Right flange surface Left flange surface Rear flange surface Right flange surface Nil Left flange surface A F J K M With indicator With indicator Without indicator Without indicator Flange side Flange side t Auto switch type r Temperature specifications XLA