The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUPPLY/EXHAUST BLOCK ASSEMBLY, VALVE, SS5V2 MANIFOLD SV2000, W1, SS5V2 BUILT IN FITTING (>1/4),
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUPPLY/EXHAUST BLOCK ASSEMBLY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4),
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUPPLY/EXHAUST BLOCK ASSEMBLY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4),
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), D-SIDE END PLATE, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .35200 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUPPLY/EXHAUST BLOCK ASSEMBLY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4),
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUPPLY/EXHAUST BLOCK ASSEMBLY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4),
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH END BLOCK ASSY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .26400
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .45100 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), ENDPLATE, D-SIDE, VALVE, SS5V2 MANIFOLD SV2000, W1, SS5V2 BUILT IN FITTING (>1/4), .44990 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .37840 lb
DRIVE ON )No.3 1 OUT1 OUT5 OUT 4 OUT 3 OUT 2 OUT 1 OUT 0 2 OUT2 OFF OFF OFF OFF ON ON 3 OUT3 4 OUT4 (1)RESET ON OFF (2) (3) () OFF 0 5 OUT5 6 7 ON 8 BUSY () BUSY OFF 9 SVRE OFF OFFON ON 10 SETON SETON()ON OFF -33- Word Bit INP ON (BUSY OFF) INP ON INP ON INP ON ()INP ON )100 80% 40%(*1) *1 11 INP 0 () INP [ON] 100 80 40 12 AREA 12 ON 13 WAREA W1 W2 ON 14 ESTOP ON
SY Replacement of Pilot Valve SYJ Caution 3 5 7 Electrical entry W1: Cable length 300 mm W2: Cable length 500 mm W3: Cable length 1000 mm W4: Cable length 2000 mm W7: Cable length 5000 mm SYJ VK Pilot valves in this series are improved to provide excellent energy saving results.
SY Replacement of Pilot Valve SYJ Caution 3 5 7 Electrical entry W1: Cable length 300 mm W2: Cable length 500 mm W3: Cable length 1000 mm W4: Cable length 2000 mm W7: Cable length 5000 mm SYJ VK Pilot valves in this series are improved to provide excellent energy saving results.
Ex. 1) Lead wire length of 2000 mm SYJ3120-5LOZ-M3 SY100-68-A-20 Ex. 2) Lead wire length of 300 mm (standard) SYJ3120-5LPZ-M3 3 5 7 Electrical entry W1: Cable length 300 mm W2: Cable length 500 mm W3: Cable length 1000 mm W4: Cable length 2000 mm W7: Cable length 5000 mm SYJ Symbol for connector assembly with cover Ex. 1) Cable length: 300 mm SYJ3120-5W1ZE-M3 Symbol for electrical entry
VQ 4 5 1 0 0
(mm) Mounting screw L2 H2 D W1 H1 P L1 W2 W3 Model (Nominal x Length) 6 3.25 72.5 4.5 5.5 6 6.5 6.5 10 5 7.5 8 12 12 8 10 11 12 12 17 21 23 25 25 6 4 2.2 2.8 2.8 3.2 3.2 2 x 6 2.6 x 8 2.6 x 8 3 x 8 3 x 8 TM-04 TM-06 TM-08 TM-10 TM-12 7.5 9.5 91.5 5.5 77.5 6 7.5 77.5 6 15 9 93 12.5 6.5 4.5 16.3 8.8 14.3 7.5 12 12 10 8 9.8 How to Use 2.
Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: Z (w/Light/Surge Voltage Suppressor, Positive Common), Manual Override: Non-locking Push Type, A,B Port Size: None, A,B Port Thread Type: Rc (or None), Mounting Option: Mounting Screw, Round Head Combination Screw, Wiring Specification: W1
Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, Continuous Duty Type), Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: NZ (w/Light Surge Voltage Suppressor, Negative Common), Manual Override: Non-locking Push Type, A,B Port Size: None, Mounting Option: B (Mounting Screw, Hexagon Socket Head Cap Screw), Wiring Specification: W1
Valve: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, Continuous Duty Type), Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: NZ (w/Light Surge Voltage Suppressor, Negative Common), Manual Override: Non-locking Push Type, A,B Port Size: C4 (ΓΈ4 One-touch Fitting), Mounting Option: B (Mounting Screw, Hexagon Socket Head Cap Screw), Wiring Specification: W1
.: LEC-W1 Or PLC To CN3 mElectric actuator/ Series LE mUSB cable Positioning unit (A-mini B type) To CN2 Power supply for I/O signal 24 VDC PC Communicationm cable mPower supply plug (accessory) Driver input power supply Supplied by customer