SMC Corporation of America
Elite Part Number Search
Search Results "VV317-02-101-02-A"

Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult P/A regarding other voltages.

VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 11.5 Dimensions (Orifice Size: 8 mm, 10 mm) VXA225/VXA226 Thread fixed: (VXA2262 0-04 only) 2-M5 x 0.8 depth 8 Dimension of view from A Pilot port Port size P Rc , With bracket E Port size View from A Model A B C D VXA22 52 60 02 03 VXA226 -04 2 0 1 4 3 8 22 28 11 14.5 67 73 77 83 27 30 1 2 Fixing with thread is also possible

Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the

Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the

Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air

Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air

PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 PFM7-01/02--X693 PFM7S-01/02--X693 -73No.PF-OMJ0006-J PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 PFM7-01/02--X694 PFM7S-01/02--X694 -74No.PF-OMJ0006-J For a mixture of Argon (Ar) and carbon dioxide (CO2) The mixture ratio can be selected from Ar : CO2 = 92 : 8, 90 : 10, 80 : 20, 70 : 30 or 60 : 40.

Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.

Helium leak volume 4.0 x 10-9 Pam3/sec or less Case/Cover Stainless steel 316 (Interior/Exterior: Electrolytic polishing) Main material Filter medium PTFE membrane Seal Fluororubber (FKM) -8- 2-3 Dimensions 1) SFC100-02, SFC100-03 Model A SFC100-02 Rc1/4 SFC100-03 Rc3/8 2) SFC102-02, SFC102-03 Model A SFC102-02 TSJ1/4 SFC102-03 TSJ3/8 3) SFC105-02, SFC105-03 Model A B C SFC105-02 URJ1/4 22

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)

15.2 40.4 35.4 15 18.5 11 R 1/4 17 34.4 29.4 55 18.5 46.5 28.2 19.7 10 ASD430F-02-10S 18.5 58 21 49.3 31 6 ASD530F-02-06S 12.8 74 17 48.3 25.2 20.3 8 ASD530F-02-08S 15.2 76 18.5 51.3 28.2 41.9 46.9 48.8 43.8 19.8 23 15.4 R 1/4 19 42.8 37.8 10 ASD530F-02-10S 18.5 80 21 54.1 32.6 23.1 12 ASD530F-02-12S 83 20.9 22 55.9 34.4 6 ASD530F-03-06S 74 17 12.8 48.3 25.2 20.3 8 ASD530F-03-08S 93 18.5

41.7 40.4 35.4 15.2 18.5 15 11 R(PT)1/4 17 34.4 29.4 18.5 55 28.2 46.5 19.7 10 ASD430F-02-10S 18.5 21 58 31 49.3 6 ASD530F-02-06S 12.8 17 74 25.2 48.3 20.3 8 ASD530F-02-08S 15.2 18.5 76 28.2 51.3 41.9 46.9 48.8 43.8 23 19.8 15.4 R(PT)1/4 19 42.8 37.8 10 ASD530F-02-10S 21 18.5 80 32.6 54.1 23.1 12 ASD530F-02-12S 22 20.9 83 34.4 55.9 6 ASD530F-03-06S 17 74 12.8 25.2 48.3 20.3 8 ASD530F-03-08S

This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 2. Speed adjustment is possible with meter-in/meter-out type speed controllers, but it may not be possible to obtain the cushion effect (smooth start-up, soft stop). 3.

(High pump head Rated current of leak voltage x size [Optional]) current (A) [mA] HRR012-A/W-101-phase AC100V (50/60Hz) 15 30 1-phase HRR018-A/W-10AC115V (60Hz) HRR012-A/W-2010 30 HRR018-A/W-203 cores x 14AWG HRR024-A/W-20(3 cores x HRR030-A/W-20HRR012-A/W-20-T 2.0mm2) 1-phase HRR018-A/W-20-T HRR024-A/W-20-T HRR030-A/W-20-T (including 200-230V AC ground) (50/60Hz) 15 30 HRR012-A/W-20-T1 HRR018

For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.

B2B2 3 rev 1 (2) (1) 200 TM MR Configurator2 PC02 MBR (MBR)OFF(Tb) 0 ms 0 1000 PC03 *ENRS 0h 0 0 A B AB CCW CW A A 0 B B A A 1 B B 0 1 0 1 PC04 **COP1 C-1 0h 0 0 0 02 14 1()(16) 11.1.2 02 1: 4 116 11.1.2 5 21 5 No.

Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.