.: 4, 5/32" (Pitch) P = 10.5 33.1 17 A A 20 15 5 B B 2 (Pitch) P = 10.5 17 M5 x 0.8 (A, B port) M8 connector (WO) L plug connector (L) M plug connector (M) 53 M8 x 1 0.8 98.6[103] 35.5 96.8 0.8 0.8 0.8 79 [83.4] 70.8 [73] 61 [63.2] 69.9 111.5 [115.9] 62.5 91.9 [96.3] 109.7 82 94.9 (Lead wire length) Approx. 300 59.6 [66.6] Approx. 300 (Lead wire length) 33.1 48.5 [55.5] Refer to page 1-5-

Consult factory for technical data and detail prints. 1/8 N.P .T . 1/2 NPT 2.06 (52.3) WITH SLEEVE PORT ADAPTER 1.50 (38.1) 2 WAY OR 3 WAY FREE EXHAUST WITHOUT SLEEVE PORT ADAPTER .61 (15.5) 3/432 UN THD. 1.86 (47.2) COAST PNEUMATICS 8055 E. CRYSTAL DRIVE, ANAHEIM, CA 92807 (714) 921-2255 WWW.COASTPNEUMATICS.COM SOLENOID VALVES . . .

Dd9 Knuckle 40, 50, 63 80 100 3 x 18l 3 x 18l 4 x 25l 4 x 25l 4 x 30l 4 x 36l CDP-2A CDP-3A CDP-4A CDP-5A CDP-6A CDP-7A 10 0.046 0.076 12 0.050 0.093 16 0.050 0.093 18 0.050 0.093 20 0.065 0.117 25 0.065 0.117 46 55.5 71 76.5 83 88 4 4 5 5 5 6 3 3 4 4 4 4 38 47.5 61 66.5 73 78 Material: Rolled steel Applicable bore size (mm) 40 50, 63 80 100 d D H B C Part no.

CXS Theoretical Output Symbol Specifications XB11 Long stroke type (N) XB13 Low speed cylinder (5 to 50 mm/s) DOperating pressure (MPa) Model Rod size (mm) Piston area (mm 2) X146 Hollow piston rod 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 X138 Adjustable stroke -X CX2N10 CX215 CX225 91 81 71 61 51 40 30 6 101 20 X168 CX helical insert thread 186 166 145 124 104 83 62 8 207 41 X169 Individual -X 2

+0.1 +0.3 +0.1 +0.3 +0.1 +0.3 +0.1 +0.3 +0.1 40 50 63 80 100 6 M8 X 1.25 14 30 27 60 22 96 1/8 1/8 44 10 29.5 16 32 10 85 15 52 16 12 12 10 8 15 to 500 7 M8 X 1.25 18 35 32 70 27 108 1/4 1/8 52 12 38 20 40 10 95 17 56.5 20 13 15 12 11 18 to 600 MXU 7 M10 X 1.25 18 35 32 86 27 115 1/4 1/4 64 16 49 20 40 10 102 17 67 20 18 12 15 11 25 to 600 11 M12 X 1.75 22 40 37 102 32 139 1/4 1/4 78 20 61

Large effective area Low power consumption AVL2000-*02 1/4 67 111 31 55 40 64 (Max. 73) Manual/Manual solenoid lock out Modular design AVL2000-*02-*DZM 1/4 67 20.5 111 31 55 34 40 64 (Max. 73) AVL3000-*03 3/8 76 118 36 57 48 64 (Max. 73) How to Order AVL3000-*03-*DZM 3/8 76 12.5 118 36 57 34 48 64 (Max. 73) AVL4000-*04 1/2 98 133 47 61 52 64 (Max. 73) G 20 00 F DZM R 5 02 AVL AVL4000

KFG2L0122-N01 KFG2L0122-N02 KFG2L0325-N01 KFG2L0325-N02 KFG2L0704-N01 KFG2L0704-N02 KFG2L0906-N01 KFG2L0906-N02 KFG2L0906-N03 KFG2L1163-N02 KFG2L1163-N03 KFG2L1163-N04 KFG2L1395-N02 KFG2L1395-N03 KFG2L1395-N04 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 10 15 10 15 15 19 20 25 28 39 42 52 48 51 61 12.5 15.9 12.5 15.9 14.7 18.1 15.8 19.2 19.6 20.9 21.3 24.5 21.9 22.3 25.5 13.7

.: 61 M3 x 0.5 (External pilot port) 6, 1/4" 8, 5/16" 10, 3/8" 2 x 3.4 (For manifold mounting) (5.5) 50.6 97.8 + 29.5 32 24.7 16.6 3 2.6 48 6.8 2 x 3.4 (For mounting) 36.6 With bracket 1/8 [5(R1), 3(R2) port] 30 Note) For bracket assembly part no., refer to page 934. 3 3 P 18 5 1 1.8 (PE port) 3 (Reverse-mounting-prevention hole) (CE-compliant models only) 2 x 3 die-cast

(See LECSC Operation Manual (Simplified Edition), section 5.7.1 for update project.) -61- 5.9.2 To Load saved Project From the Project menu in the setup software, select Open. Please select the "drive path name project name" that you want to read parameters are stored. Please select the file you wish to import project [.mrc2]. Click Open.

Adjust gains. 8 61 8. TROUBLESHOOTING Description Possible cause Check result Action Target An unusual noise is occurring at the servo motor. The servo gain is low. Or the response of auto tuning is low. Check if the trouble is solved by increasing auto tuning response ([Pr. PA09]). Adjust gains. LECSS2 -T Bearing life expired.

No.PS-OMU0005CN-C // ZSE20B(F) ISE20B 2 8 10 11 15 15 17 20 [] 23 24 3 25 27 29 29 29 F0 31 F1 OUT1 32 F1 OUT2 35 F3 37 F4 38 F5 FUNC 40 F6 42 F10 43 F11 49 F80 50 F81 51 F82 53 F90 54 F96 56 F97 57 F98 59 F99 61 62 66 66 67 76 76 79 -1No.PS-OMU0005CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO

ONOFF (31 ) ON OFF 31 61 61 ON OFF Hysteresis / () () 25[]ON-OFF -11No.PS-OMS0006CN-G NPN () () ON ON 0 31 ON-OFF ON ( )(P1L~P1H) ON (31 ) () "digit" () 0 () SI ON/OFF ON-OFF / ON/OFF 90 ON -12No.PS-OMS0006CN-G ON ( )(n1L~n1H) ON (31 ) 31 (0FF)(ON)(OFF)(ON) () 5%R.D.(5%) (0~1MPa 0.001MPa 1/1000 () () F () ripple -13No.PS-OMS0006CN-G (3X8L(2 ) 0.50.05 Nm ,, A

Outline of IO-Link function 61 Communication specifications 61 Process data 62 IO-Link parameter setting 65 Maintenance 73 Forgotten the security code 73 Troubleshooting 74 Specifications 83 Dimensions 85 -1No.PS-OMY0007-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

No.PS-OMR0001CN-J // ISA3 1 2 7 8 14 15 2 (ISA3) 15 () 16 (2 ) 16 17 20 26 26 29 34 38 3 41 42 44 44 44 45 45 4 46 46 46 () 58 59 60 5 61 62 62 -1No.PS-OMR0001CN-J 1 (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety

) IP67IP65 -5No.PS-OMT0001CN-E 1 42 LCD VX2 (2 )AR20 () -6No.PS-OMT0001CN-E 2 (0.01mm0.03mm0.02 mm0.15 mm0.05 mm0.30 mm) ON()/OFF()() (A)() (B)() (C)(B)() -7No.PS-OMT0001CN-E 2 2 DIN 9 F 0.010.03mm 0.020.15mm 0.050.30mm G H 7 10 B Rc1/8 4 1 6 2 1 3 G1/8 G1/8 3 7 NPN2 PNP2 A B 4 L 7 5 SI N 1 2 3 1 2 3 4 5 6 S 6 7 8 4 5 6 6 7 8 T 1F 2GH 3ISO1179-1 4 5kPa 61

) 16 9 32 1(P) 17 1(P) 10 10 P = 11 4 36.5 L1 L2 4 41.5 45 C4: 4 One-touch fitting M plug connector (M) Stations D side U side 1 2 3 4 5 n Direct manual override (Non-locking) 2n x C4, M5 4(A), 2(B) port C4: One-touch fitting for 4 M5: M5 thread 2(B) 2(B) 27.5 20 15 4(A) 4(A) 5 P = 11 12.5 (46) L plug connector (L) n: Stations Dimensions n L 11 138 130 10 127 119 L1 L2 2 39 31 3 50 42 4 61

A dimension B dimension Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 Bore size (mm) 10 35 35.5 45 44.5 40.5 39.5 15 34.5 35 63 62 40 57.5 20 64.5 65 50.5 50 70 45 25 44 44.5 71.5 71 49.5 66 32 55 55.5 83.5 83 60.5 78 40 61

KGH06-03 22 15.5 17 27 21 19 26 19 30 Connection thread 1 8 1 4 3 8 1 8 1 4 KGH08-01 KGH08-02 KGH08-03 KGH10-01 KGH10-02 28 26.5 22 30 33.5 24 20.5 15.5 26 27.5 14 26.1 8 18.5 18.0 17 Applicable tubing 17 41.5 10 21 29.5 3 8 KGH10-03 29 22.5 30 1 2 KGH10-04 27 19 53 42 34 22 1 4 3 8 KGH12-02 KGH12-03 34.5 28.5 19 12 23.5 22 58.3 46.1 30 1 2 3 8 1 2 KGH12-04 KGH16-03 KGH16-04 51 61

Join X to 0.28 m3n /s and draw a line to intecect the pipe size lines at approximatly 61 mm. Pipe with a minimum bore of 61 mm can b used. a 65 mm nominal bore pipe (see Table 4.21) has a bore ol 68 mm and would satisfy the requirements with some margin.

Solid state with diagnostic output Solid state with latch type diagnostic output Note 3) For solid state with flexible wire specification, enter "61" after the lead wire length.