Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.
or less Protection Polarity protection Power supply voltage for sensor1 [Power supply voltage] 1.5 V Power supply current for sensor2 Max. 50 mA (However, the total current for the 4 inputs is 200 mA maximum or less.)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: [Others] Other, Pipe Port Type: [Rc (R)] Rc, Port Size: 1/2, Pressure Rating(MPa): 0.25 to 0.7, Driving Type: Pilot
Model: 7 (VP700), Pilot: Internal Pilot, Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: Rc, Switch Electrical Entry: G 1/2, OMRON, Check Valve, External Pilot Only: None
Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at
Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at
NPN or PNP open collector 1 output Switch output Main circuit Main circuit Load 12 to 24 VDC Maximum load current 80 mA + Black OUT Maximum applied voltage 30 V (at NPN output) Residual voltage 1 V or less (with load current of 80 mA) Response time Anti-chattering function 1 s (0.25, 0.5, 2, 3) Blue DC () PNP open collector Max. 80 mA Residual voltage 1 V or less Short-circuit protection
25 to 85C (with no freezing and condensation)NPN open collector: Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA); Maximum applied voltage: 30 V; 2 outputsPNP open collector: Maximum load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA); 2 outputsNPN or PNP open collector (same as switch output)Illuminates when output
Note 3) Install a circuit breaker with sensitivity of 30 mA. Note 4) IDU11D to 75C-4/6 are only for frequency of 50Hz. Note 5) Spare part for auto drain INA-20-41-04 is AD44-x445. Operation Principles Compressed air inlet Compressed air outlet IDU11D, 11C, 15C Humid hot air entering the air dryer is cooled in the after-cooler.
FC2W-X110 How to Order Piping port size Flow rate control range Symbol Port size 03 3/8 0.5 to 4.0 L/min FC2W504 03 X110 3 2.0 to 16.0 L/min FC2W520 X110 3 04 Piping port size Lead wire 3 Lead wire with connector (3 m) Symbol Port size 04 1/2 Specications Model FC2W504-03-3-X110 FC2W520-04-3-X110 Applicable uid Water Flow rate detection method Karman vortex Flow rate control range 0.5 to
DC (+) 1 NC 2 Flow direction DC () 3 OUT 4 8 Digital Flow Switch for Water Series PFW How to order 20 03 27 PFW7 Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications 27 67 NPN (2 outputs) PNP (2 outputs) Piping port size 03 04 06 3/8 1
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
), 0.5 W DC (21 mA) (4) 24 VDC Power consumption (Current) 1 W DC (83 mA), 0.5 W DC (42 mA) (4) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 12 VDC Metal seal Rubber seal Note 1) Use dry air to prevent condensation when operating at low temperatures.
100 VAC, DC: 20 mA Plug-in type VVZS2000-14A Non plug-in type IS1000-00-X204 Non plug-in type Pressure switch VS4 Max. operating current Caution Operating voltage Air release valve (Single only) Operating pressure range 100 VAC, DC or less When using an air filter with auto-drain or manual override drain, mount the filter vertically.
5 to 100C) For low temp. environments (30 to 60C) T Note 4) Semi-standard Type of setting L Note 5), 6) 0 1 Note 1) Basic type (Knob) Air operated type Suffix 2 Set pressure range Nil For IR1000/2000 series Port size Bracket, Name plate, Mounting on the opposite side R Note 7) 0 1 2 0.005 to 0.2 MPa 0.01 to 0.4 MPa 0.01 to 0.8 MPa Application Size Symbol IR1000 IR2000 IR3000 01 02 03 04
Low power consumption: 0.6 W (Current draw: 25 mA at 24 VDC) High reliability and long service life exceeding 50 million cycles or more Low power consumption enables direct operation by a PLC. Cost savings are realized through the use of a smaller power supply and the elimination of relay cards.
Adaptor connection thread Symbol Pad dia. 1 02 to 08 B5 2 10 to 16 3 20 to 32 B8 4 40, 50 T 2 ZP B5 [qAdaptor] R S ZP 04 A5 [wR type adaptor] Symbol S Pad dia. 02 to 16 L 20 to 50 With Buffer ZP R 16 K20 A10 06 UGN [Pad model no.]
Valve model Port size VCL2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCL4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCL Direct Operated
Valve model Port size VCS21 VCS20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCS30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCS30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCS30-12-04 VCS41 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCS Direct Operated
NPTF Bottom 04 sP0105 %,,NPTF SidE 5 AXT 333-21 Terminal Block Subolate ME4OI SLR Lell and Right end plates-Shorl w/o conduil NPT threads. Includes (3)O-rings AFP 568-015 1 pr.