0 r FG Frame ground (Tighten the screw with the washer when mounting the controller. Connect the ground wire.) !1 !
DATA SET1 2 OUT 1 2 3 SET MONOSASHIKUN Shielding should be connected to FG (frame ground).
Dimensions for auto switch model D-F79W. 15 Scale Cylinder Series CE1 Foot type CE1L Bore size Stroke LT LE LH 3.2 LB LA 4-O (Special cap bolt) 4-LD LX LZ LS + Stroke A + Stroke LY Front flange type CE1F Bore size Stroke 4-FD FT FV M FX FL 4-O (Special cap bolt) A + Stroke FZ FG Rear flange type CE1G Bore size Stroke 4-FD FT FV M FL FX A + Stroke 4-O FZ (Special cap bolt) FG Double clevis
Note) Do not apply rotational torque to the piston rod. q MK/MK2 RSQ/RSG Connect the shield wire to FG (frame ground).
r FG !1 !2 t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 Switch the mode between manual and auto. Mode swith !3 !4 Stop position, the value set by 8 and alarm information are displayed. 7-segment LED SET Decide the settings or drive operation in Manual mode. Set button Assign the position to drive (1 to 14), and the origin position (15).
Connect the shield wire to FG (flame ground). 2. The maximum transmission distance for the stroke reading cylinder is 23 m, but since the output signal is a pulse output, the sensor cable should be wired separately from other power lines.
Speed Controller with One-touch Fitting Stainless Series Series AS-FG/ASD-FG . Series AS-FG Speed Controller with One-touch Fittin Stainless Series. 5 5 6 7 9 11 11 11 11 12 13 13 13 15 15 16 16 16 17 17 18 19 21 22 22 23 24 25 27 27 27 29 30 31 31 31 32 34 35 35 35 36 36 37 37 37 38 38 39 39 39 41 42 43 43 43 44 45 46 46 Specifications. How to Order . Construction. Dimensions .
Yellow RESET Connect to the FG wire of the counter cable. Green FG Use the I/O cable (LATH2-m) to connect a PLC, etc., to the CN5 parallel I/O connector. The wiring is specific to the type of parallel I/O (NPN or PNP). Please refer to the wiring diagrams below for correct wiring of NPN and PNP type controllers.
r FG !1 !2 t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 Switch the mode between manual and auto. Mode swith !3 !4 Stop position, the value set by 8 and alarm information are displayed. 7-segment LED SET Decide the settings or drive operation in Manual mode. Set button Assign the position to drive (1 to 14), and the origin position (15).
contents RS-232C RS-485 1 Unused BUS+ 2 RD Unused 3 SD Unused 4 Unused Unused 5 SG SG 6-8 Unused Unused 9 Unused BUS 8 Contact b for output cutoff alarm (closed when alarm occurs) 3 9 Contact a for upper/lower temp. limit alarm (open when alarm occurs) 10 Common for upper/lower temp. limit alarm 4 11 Contact b for upper/lower temp. limit alarm (closed when alarm occurs) 12-14 Unused 15 FG
A + Stroke 4 x O FZ (Special cap bolt) FG CE1D Double clevis type: Bore size Stroke 4 x O 0.1 0.3 +0.4 +0.2 CX CZ CD hole H10 CU Shaft d9 T CW RR CL + Stroke A + Stroke (mm) Head side flange Rod side flange Common Foot type Rod side flange, Head side flange Double clevis type Bore size (mm) LT FT LA LB LE LH LX O A LD LS LY LZ FD FG FL FV FX FZ M A A A CD CL CU CW CX CZ RR T 32 40 50 63 M6
FG is meant for preventing lightening strike, use wire, 0.75mm2 or more in the diameter of wire sectional area, to connect to earth. If FG is not connected to earth, controllers noise filter will not be able to function properly. Hence, noise ill be generated and lead to misreading / disoperation of cylinder. 9-2-2 The Connection of Extension Cable Use specified (SMC) extension cable.
FG 9-2-2 5m 20m5m CE1-R U 25mm *400 200mm 1 R25 100 / 32 9-3 9-3-1 13 2 AC100V +12V (AC100V15%) 12 COM GND COM SENSOR INPUT FG A B 1 11 F.G 10 24E (24V10%0.4A) COM +24V 4 9 COM 3 8 BR 2 7 B VAL.OUT OUTPUT 1 6 A END INPUT COM 4 5 COM 4 3 / 3 COM DIP SW 2 2 ON 1 COM COM 1 1 2 3 4 1. 2.ON OFF 3. 4. 33 9-3-2 50msec 1 50msec 50msec / COM 1 1 1No112No12COM COM 5mm Err5
Supply port PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 2.6 3.3 5.1 6.8 8.6 9 12.5 16.5 20 24.5 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth
BB Attached from top with CAP bolt Bolt size: MD LA A 4Counter bore depth CC X A FG 4-BA LF Body Switch rail FG X A FH XA HB Note 1) FF Note 1) HL D' FE Note 1) Floating block Section D-D' D 20, 25, 32, 40, 50, 63 Attached from top with CAP bolt Floating block L LA A XB WF Attached from bottom with CAP bolt 2-SS (helical insert screw) Body FG XA LF Bolt size: MD R Note 2) S HL FF Note 1)
CWL CCWL ALM COIN SP A 35 Driver model MSD013P1E MSD011P1E MSD023P1E MSD021P1E 45 Z phase output Z phase output Z phase output CW pulse input CW pulse input CCW pulse input CCW pulse input Frame ground 60 OZ CZ CW+ Command divider switching input CW drive suppression input CCW drive suppression input Servo alarm output CW CCW+ CCW Positioning complete signal output Speed monitor signal FG
CWL CCWL ALM COIN SP A 35 Driver model MSD013P1E MSD011P1E MSD023P1E MSD021P1E 45 Z phase output Z phase output Z phase output CW pulse input CW pulse input CCW pulse input CCW pulse input Frame ground 60 OZ CZ CW+ Command divider switching input CW drive suppression input CCW drive suppression input Servo alarm output CW CCW+ CCW Positioning complete signal output Speed monitor signal FG
CWL CCWL ALM COIN SP A 35 Driver model MSD013P1E MSD011P1E MSD023P1E MSD021P1E 45 Z phase output Z phase output Z phase output CW pulse input CW pulse input CCW pulse input CCW pulse input Frame ground 60 OZ CZ CW+ Command divider switching input CW drive suppression input CCW drive suppression input Servo alarm output CW CCW+ CCW Positioning complete signal output Speed monitor signal FG
M-5P (Width across flats 7) 32 : Hexagon socket head taper plug (Width across flats 5) Refer to the Figure 1 for G thread PC PB PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 9 12.5 16.5 20 24.5 22 34 43.5 58 73 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 2.6 3.3
Connector on the output device side M12 connector (5 pins, plug) Enclosure IP67 10 to 50C Operating temperature range Operating humidity range 35 to 85%RH (with no condensation) Environmental resistance Withstand voltage 1500 VAC for 1 min. between external terminals and FG 10 M or more (500 VDC) between external terminals and FG Insulation resistance 10 to 150 Hz with a 0.35 mm amplitude