HAA7 to HAA22 HAA37 Dustproof filter Tapping screw 6-nominal 4 Rear panel Rear panel Dustproof filter Tapping screw 6-nominal 4 Dustproof filter replacement part number Applicable model HAA7 HAA15 HAA22 HAA37 Dustproof filter number HAA7-F HAA15-F HAA22-F HAA37-F HAA Series 14 9 4)Dustproof filter Assembly Procedure (Option Symbol: F) ATX-OM-F004E Air-Cooled Aftercooler 10.
When used in stopper application mounting hole, diameter should be 2d or more = E b o I il Cro.z Compact Guide Cylinder:Series MGQ Permissible lateral load (Ordinary-use load) F + 12 t6 ' i 4 : : : 49 25 51 F t 108 A6 104 176 3 3 206 686 343 80. : . l ' s s i 1070 lN=OlO2kql r(N.m) Bore size Modd to 20 r 3 B ' .50 75 .t( P , 0.29 o.24 o.21 0.18 0.16 0.48 o.39 0.31 o.37 0.33 -^ I McoM 0.51
TA DL2 TF TG A S + Stroke H NA F ZZ + Stroke Section TA With non-locking type manual override (suffix N) With locking type manual override (suffix L) HN HR MO RF WL WL KA 0.1 C 8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)
(www.smcworld.com)JMHZ2 Series P .15 mm 16 MPa 0.1~0.7 (oC) -10~50 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 (mm) 10 (g) 700 M8 8 MOLEX (51227-0800) 7 - 3-3. 2 1 F 8 - 3-4. H 9 - 3-5. JMHZ2-16D-X7400B-HC10-(*) P13P14P15 4 M6 31.5 2XM4x0.7 8 4 M6 108.8L 4 4 M4 4 M3 27 17 10 - JMHZ2-16D-X7400B-HC10DT-(*) 4 M6 32.5 8 4 M6 109.8L 4 4 M4 4 M3 27 17 11 - 3-6.
(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.
Max. 1.3A Max. 2.3A L C 3 F 2 1 2 5 [] [] [] (1)(2) Check voltage between DC(+) and DC(-) Supply 24VDC 10%.
0.50.6Nm 0.50.6Nm + M3 0.50.6Nm A-A () -9No.PS-OMF0005CN-E * 30 * 1 2 3 O 4 (0.40.5 Nm) (AR ) * 0.020.2 MPa 0.2 MPa 0.2 MPa ([]) ([] ) ()60mm -10No.PS-OMF0005CN-E N P R 1 IISA2 C S L 6 5 D E 2 IISA2 *1 16 1~6 C +2 *2 *A V 2 E2 (MPa) 0.2MPa 0.4MPa G2 (MPa) *P2 (MPapsi) SR *Z2 (psi) SL E4 (MPa) PR G4 (MPa) PL *P4 (MPapsi) * *Z4 (psi) * *1psi *21/8 B D DIN + 2 C 1 AC100V
0.8Nm SY7000 M4 1.4Nm SY9000 M3 0.8Nm 13 No.SY3000-OMH0002 SY series 1) P 2) P 3) (2 ) 1 0.5MP 4) 5) AB (P AB )0.25MPa (PB PA)(Cv ) 14 No.SY3000-OMH0002 () (E) () () (PE) 15 No.SY3000-OMH0002 No. 1(ISO VG 32) (R) E 16 No.SY3000-OMH0002
A Mounting screws (M3 x 8L) (accessory) Waterproof seal (accessory) Panel mount adapter Power supply/Output connection cable ZS-26-A Panel Front protective cover + Panel mount B Mounting screws (M3 x 8L) Front protective cover (accessory) Waterproof seal (accessory) Panel mount adapter Panel Options When only optional parts are required, order with the part numbers listed below.
Model number: HRS040-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Model number: HRS050-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
M1 M2 2 Series CYP Dimensions T Y Depth ED T L E F PA K 4-MM 4-Counter bore dia.
How to order HF2BFB 30 02 (1) (2) (3) (4) (5) (2) Symbol Details Body size 30 40 BFA Antibacterial Filter (5m) BFB Antibacterial Filter (0.1m) (1) Filter type BFC Odor Removal Filter BFD Bacteria Removal Filter Nil Rc N NPT (3) Thread type F G 02 1/4 (4) Port size 03 3/8 04 1/2 Nil Flow direction: left to right (5) Semi-standard R Flow direction: right to left 10 5.
(G thread)" or "N (NPT thread)" is selected, it becomes "G thread " or "NPT thread ". 2 When the piping screw type "F (G thread)" or "N (NPT thread)" is selected, a conversion joint is included.
(G thread)" or "N (NPT thread)" is selected, it becomes "G thread " or "NPT thread ". 2 When the piping screw type "F (G thread)" or "N (NPT thread)" is selected, a conversion joint is included.
Bore size (mm) 32 40, 50, 63 80, 100 Thread size M2.5 X 0.45 X 25 l M3 X 0.5 X 30 l M5 X 0.8 X 40 l Pulling force 4.9N 10N 24.5N Stroke (mm) 2 3 3 e Release lock when mounting or adjusting the cylinder. If mounting is done with lock engaged, lock mechanism may be damaged. * Remove bolt under normal operations.
Connected A B C D E F G H I J IDF190D JIS10KFF 80A(3B) flange 750 1510 1320 375 480 600 700 800 355 427 IDF240D JIS10KFF 100A(4B) flange 770 1550 1640 385 703 730 700 800 355 467 Auto drain is included in the package.
If the cable length exceeds 5m, the speed/thrust will decrease by up to 10% for every 5m. (For 15m: Max. 20% reduction) Note 5"Pushing speed is the allowable speed for the pushing operation. When transporting and pushing a workpiece, operate the actuator with the "vertical load capacity" or less. Note 6This is a reference value for correcting errors in reciprocating motion.
DC1224 V DC1224 V 8 DC(+) DC(-) DC1224 V DC1224 V DC(+) 9 DC(-) / / 10 ( ) 11 / 5m / 12 2030 20 -28No.PS-OMG0001CN-H No.
Side Thread Type Nil Rc G NPT NPTF T F F 1 2 3 4 N.O. N.C. N.O. N.C. N.O. N.C. N.C. N.O. Manifold Type 1 0 Side Ported Top Ported Rated Voltage, Elec.