Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
Note 5) Spare part for auto drain INA-20-41-04 is AD44x445.
VHS400-02 VHS401-02 VHS400-03 VHS401-03 VHS400-04 VHS401-04 Pipipng direction VHS500-06 VHS501-06 SA Right IN1 (P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2) Weight (kg) VA 1 (P) 2 (A) 21 105 76 54 35 35 57 93 2 (A) 3 (R) SA 0.25 0.34 Left or right to the front face of the handle.
. * The load ratio is obtained by the following formula: ((Load mass x 9.8)/Theoretical output) x 100% VEX VEX Conditions System Solenoid valve Speed controller Silencer Tubing diameter x Length A VEX31 22-02 AS4000-02 AN20-02 10 x 1 m B 12 x 1 m C VEX33 42-03 04 AS420-03 AN30-03 12 x 1 m D AS420-04 AN40-04 SGP15A x 1 m 1723 3 Port 3 Position Valve Body Ported VEX3 Series How to Order Air
Put a hexagon socket head cap screw (M3 x 0.5 x 14 L) through the auto switch's through-hole (2 locations), and then push it down into the M3 tapped part on the auto switch mounting bracket while turning it lightly. 3.
Auto switch mounting band D-B54 BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) DNote 1) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform, methylamines, hydrochloric acid or sulfuric acid is splashed over, so it cannot be used. Please contact SMC regarding other chemicals.
(ANR)) 4B 1B B AMF250 AMF650 AMF1000 1 4 0.1 MPa 0.1 MPa 0.1 MPa Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) 2B AMF350 AMF800/801 B 3 8 0.1 MPa 0.1 MPa Pressure drop (MPa) Pressure drop (MPa) Max. flow line Air flow rate (m3/min (ANR)) Air flow rate (l /min
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10 10.5 M5 x 0.8 M3 x 0.5 16 11.5 M6 x 1.0 M4 x 0.7 20 13.5 M8 x 1.25 M5 x 0.8 25 16.5 M10 x 1.25 M6 x 1.0 28 22.5 M14 x 1.5 M8 x 1.25 Clevis pin d Dd9 m m l t L t Applicable bore (mm) Applicable snap ring Part no.
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10 10.5 M5 x 0.8 M3 x 0.5 16 11.5 M6 x 1.0 M4 x 0.7 20 13.5 M8 x 1.25 M5 x 0.8 25 16.5 M10 x 1.25 M6 x 1.0 28 22.5 M14 x 1.5 M8 x 1.25 Clevis pin d Dd9 m m l t L t Applicable bore (mm) Applicable snap ring Part no.
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10.5 M3 x 0.5 10 M5 x 0.8 11.5 M4 x 0.7 16 M6 x 1.0 13.5 M5 x 0.8 20 M8 x 1.25 16.5 M6 x 1.0 25 M10 x 1.25 22.5 M8 x 1.25 28 M14 x 1.5 Clevis pin part numbers d m m l Dd9 t L t Applicable bore size (mm) Applicable snap ring Part no.
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10 M5 x 0.8 M3 x 0.5 10.5 16 M6 x 1.0 M4 x 0.7 11.5 20 M8 x 1.25 M5 x 0.8 13.5 25 M10 x 1.25 M6 x 1.0 16.5 30, 40 M14 x 1.5 M8 x 1.25 22.5 Clevis pin d Dd9 m m l t L t Applicable bore size (mm) Applicable snap ring Part no.
L N PE M3 6.5mm 1.25mm 2 :17 1 2 2 2 , 2 1 IDFA6E 20kg 2 2 2 2 2 1 240 050 ( ) 2000m 600mm 600mm 600mm 600mm 600mm 2 1 2 2 2 2 6 6-2 2 2 3 50 50 2 2 4 10mm ( 2 2 2 2 2 5 6-1 IEC AC200V 30mA 5A 1.25 216AWG,3 ,812 0.1m 30m M3 1.25-3 6.5mm () M3 0.61Nm 2 3 2 2 3 () 2 2 () 2 4 3 / 3 3 1 INOUT 3 2 ON () INOUT 5 ONOFF 0.15MPa NO IN 3 1 3 / 3 3 OFF OFF
L G ZA F H K J ZX I B C E D A ZR ZM 2 x M3 countersunk head screw mounting hole ZMA ZQ ZH ZU ZFC10, 20 ZL Applicable tubing O.D.
Bore size (mm) 40 10 Auto switch model 50 63 80 100 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F/F5NTL BT-04 BT-04 BT-06 BT-08 BT-08 1 100 D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G59F D-G5NTL 1000 500 BDS-04M BDS-05M BMBI-063 BMBI-080 BMBI-100 Maximum speed (mm/s) (Example) Find the upper limit of rod end load when an air cylinder of 63 is operated at 500 mm/s.
How to Order Integrated Display Type PF2W7 20 T 03 27 Flow rate range Unit specification T Temperature range 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 04 20 40 0 to 90C Nil M With unit switching function Lead wire (Refer to page 35.)
from the VY Valve. 02 14 2.0 3 03 38 3.3 body Ported Type 04 12 3.9 Terminal Designations are as follows: 04 12 7.2 5 06 34 8.9 1 = 24v Power Supply 2 = Control Signal 3 = Common Negative for both power and signal. 10 1 10 5% 2% + -2% 7 10 1 114 17 12 114 18 9 14 112 2 33 20 2 37 Courtesy of Steven Engineering, Inc. !
Bore size (mm) Applicable switch Note 175 200 250 300 400 500 150 125 100 75 25 50 12 Switch mounting screw (M3 x 0.5 x 8l) Square nut D-A7, A8 D-A7H, A80H D-A73C, A80C D-A79W D-F7V D-F7, J7 D-J79C D-F7WV D-F79W, J79W 12 20 BQ-1 20 32 32 40 50 63 40 Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut 50 BQ-2 63 Contact SMC regarding non-standard strokes.
A Mounting screw (M3 x 8L) (Accessory) Waterproof seal (Accessory) Option 2 Panel mount adapter Nil None Panel Sensor connector (4 pcs.) Front protection cover + Panel mount adapter 4C B Connector Mounting screw (M3 x 8L) (Accessory) Front protection cover Connector is not connected, but shipped together. This connector cannot be used with the PSE570 series.