to +24 VDC (Voltage: Between 19 VDC and power supply voltage, Current consumption: 5 mA or less) Input signal Static electricity removal completion signal Maintenance detection signal Error signal Sensor monitor output Note 3) Max. load current: 100 mA Residual voltage: 1 V or less (Load current at 100 mA) Max. applied voltage: 28 VDC Max. load current: 100 mA Residual voltage: 1 V or less
(i) Side Entry Single Sub-base for use with the Base Mounted Valve (Type 40). (ii) 2-10 Station Type 20 Mmanifold for use with the Body Ported Valve (Type 20). (iii) 2-10 Station Type 40 Side Entry Manifold for use with the Base Mounted Valve (Type 40). (iv) 2 10 Station Type 40 Bottom Entry Manifold for use with the Base Mounted Valve (Type 40).
High Rigidity and High Precision Slider Type LEKFS Series LEKFS25, 32, 40 How to Order w y e r t u i q LEKFS 32 E A 300 R1 CD17T q Size w Motor mounting position e Motor type r Lead [mm] 25 32 40 Nil In-line R Right side parallel L Left side parallel Symbol LEKFS25 LEKFS32 LEKFS40 H 20 24 30 A 12 16 20 B 6 8 10 E Battery-less absolute (Step motor 24 VDC) y Motor option t Stroke*1 u Actuator
In-line In-line In-line Electrical entry direction 3-wire 2-wire Wiring type NPN PNP Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 28 VDC or less 24 VDC (10 to 28 VDC) Load voltage 2.5 to 40 mA 40 mA or less Load current 4 V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal
, 24 VDC JIS Symbol Allowable voltage fluctuation 10% of rated voltage 2 position single Coil insulation type Equivalent to class B 2(B) (A)4 24 VDC 0.4 W DC (17 mA), 0.95 W DC (40 mA) (3) Power consumption (Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80 mA) (3) (R1)5 1 (P) 3(R2) Note 1) Use dry air to prevent condensation when operating at low temperatures.
40 to +80C 25 to +60C 40 to +80C Cable 25 to +60C 40 to +80C 25 to +60C 40 to +80C Min. bending radius (Fixed) 40 mm 21.7 mm 40 mm 21.7 mm Protection class IP67 (Only with screw tightened) Allowable repeated insertion/withdrawal 200 Material of knurl Brass (Nickel plating) Zinc die-cast (Nickel plating) Brass (Nickel plating) Zinc die-cast (Nickel plating) Contact (Surface treatment) Phosphor
) Note 40) Note 40) Note 40) ION BALANCE OFF ON Display Ions are generated (green) Note 40) OFF ION/HV ON 1Hz 1Hz 1Hz 1Hz 1Hz Incorrect high voltage (red) Note 45) Note 44) Note 42) Note 43) Note 44) Note 44) OFF ON Product type IZTP41(green) IZTP42(blue) DAC/AC OFF ON Maintenance (green) NDL Note 47) Note 47) Note 47) Note 47) OFF ON Built-in sensor (green) SNSR Note 48) Note 48) Note 48
Nil Air operated Nil Note) Air operated 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC ( Hz) 110 VAC ( Hz) Filter specifications (F) L LN Lead wire length 0.3 m L plug connector type 5 6 V S R Nil No setting Without lead wire Unit specifications LO Without connector M Lead wire length 0.3 m Digital pressure switch for vacuum (ZSE30A) specifications (D) M plug connector type Nil M P With unit switching
Relay Circuit Example Line Receiver Circuit Example DRIVER 5 to 12 VDC DRIVER 5 to 24 VDC Relay 0 V Note: The maximum allowable voltage and the allowable range of current capacity for photocoupler output circuits are as follows.
28 40 33 50 33 50 0.7 0.5 1 2 3 4 1.0 0.8 1.4 1.2 1 1 4 1 2.4 2.2 5.2 5.0 32 1 2 1 3.8 3.6 JIS Symbol 7.0 6.8 40 Valve type Operation N.C.
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Serial wiring: EX180 Response Time Type of actuation Response time ms (at 0.5 MPa) SJ2000 SJ3000 2 position single 2 position double 3 position 4 position dual 3 port valve 16 or less 10 or less 34 or less 30 or less 16 or less 10 or less 22 or less 30 or less Gateway system Serial transmission system
J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.
Rated voltage (with connector and 2 of sockets only) Lead wire length Nil 300 mm 6 600 mm Electrical entry 5 24 VDC 6 12 VDC 10 15 20 25 30 50 1000 mm G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm V 6 VDC S 5 VDC L With lead wire L plug connector R 3 VDC LN Without lead wire 50 60 1 100 VDC Hz LO Without connector With lead wire Without lead
12, 16 ) Note 2) 2 (Different surfaces, Same surface) 1 85 90 95 D-M9 D-M9W (n 2) 2 15 80 80 + 40 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 85 + 40 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 90 + 40 (n 4) 2 95 + 40 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 15 + 40 n (n = 2, 4, 6, 8 ) Note 1) (n = 4, 8, 12, 16 ) Note 2) 2 (Different surfaces, Same surface) 1 60 65 70 D-M9V D-M9WV (n 2) 2 10 55 55 + 30
Regeneration option C D Control circuit power supply (24 V) 24V side of the control circuit power supply (24 VDC) which supplies the controller. L11 L21 L11 Control circuit power supply (0 V) 0V side of the control circuit power supply (24 VDC) which supplies the controller.
Port size For sub-plate, manifold type 40, 41, 42, 43 Nil: Without sub-plate R port P, E port 3: Common exhaust type for main and pilot valve D: Push-turn locking slotted type R port P, E port (With gasket and screws) 01: 1/8 With sub-plate Electrical entry 24, 12, 6, 5, 3 VDC M8 connector 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC 24,12 VDC 100,110, 200, 220 VAC Grommet L plug connector M
supply circuit breaker Specific Product Precautions 24 VDC Figure 2.
CDQ2 series) side by side, maintain 40 mm minimum around the motor. 40 40 40 40 40 40 40 40 Air cylinder installation with an auto switch is forbidden in the shaded area. Example 2 When installing electric actuator LEY(G) or LEFEQFEQY series with an auto switch by side, leave a gap of 40 mm or more with respect to the position where the magnet passes.
VX31 VX31 VX32 VX33 1/8 1/4 1/4, 3/8 1/4, 3/8 50 42 61 1.5, 2.2, 3 36 41 42 42 18 93 22 76.5 30 19 19.5 27 19.5 40 42.5 58.5 46.5 92 42.5 17.5 50 75.5 40 1.5, 2.2, 3 2.2, 3, 4 2.2, 3, 4 20.5 24 24 90 35 40 22 22 22.5 32 36 22.5 60 43 46 52.5 61.5 52 49.5 95 98 52.5 64 21 57 57 89 21 106.5 47 47 98 25 25.5 68.5 61 64 60.5 52 61 66.5 21 97 21 114.5 21 Series VVX31/32/33 For Air, Oil / Manifold
to 24 VDC Black OUT + + + Blue DC() Load 12 VDC to 24 VDC 12 VDC to 24 VDC Load White OUT 2 White OUT 2 Load Load FUNC Blue DC() FUNC Blue DC() Max. 80 mA Residual voltage: 2 V or less Max. 28 V, 80 mA Residual voltage: 2 V or less Voltage output type: 1 to 5 V Output impedance: Approx. 1 k The FUNC terminal is connected when using the copy function.