Mounting: Foot, Bore Size: 32mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 120mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 3 pcs.

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket

Mounting: L (Foot), Bore Size: 32mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 200mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Mounting: L (Foot), Bore Size: 32mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 120mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 3 pcs.

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket

A current sensor abnormality has occurred. (01-195) Make sure that the electric actuator conforms to the controller. When a command to turn on servo is given, check if LK RLS is energized by installing the electric actuator vertically in order to check if the motor is driven by an external force.

ON DRIVE ON 1-099 SETOFF DRV C RESET 12 (1-103) 1 [] A [a ] C RESET 2 [SW] [] A [a ] () (1-106) C RESET SVON 1 1-144 RESETS VON (1) D 50 - ON (M24V) 1-145 RESETS VON (1) D 1-146 RESETS VON (1) D (C24V) RESETS VON (1) 1-147 D (1-148) RESETS VON (1) D 51 - 1-149 RESETS VON (1) D 1-150 D RESETS VON (1) 1-192 E ON(SVON ON) 1-193 E ONSVON ON 1-194 E 1-195

ON DRIVE ON 1-099 SETOFF DRV C RESET 12 (1-103) C RESET 1 [] A [a ] 2 [SW] [] A [a ] () (1-106) C RESET SVON 1 1-144 RESET SVON (1) D 50 - ON (M24V) 1-145 RESET SVON (1) D 1-146 RESET SVON (1) D (C24V) RESET SVON (1) 1-147 D (1-148) RESET SVON (1) D 51 - 1-149 RESET SVON (1) D 1-150 D RESET SVON (1) 1-192 E ON(SVON ON) 1-193 E ONSVON ON 1-194 E 1-195

DRV C 0: () 1: OFF 0: a 2: OFF B (1-103) 0: C RESET OFF ON 1: a 2,3: 2: OFF ON B 0 "0" 2 3 62 - () (1-106) RESET SVON C 1 (1-144) RESET SVON D ON (M24V) (1-145) RESET SVON D (1-146) RESET SVON D (C24V) (1-147) RESET SVON D 63 - (1-148) RESET SVON D (1-149) RESET SVON D () (1-150) RESET SVON D (1-192) E ON(SVON ON) (1-193) E ON(SVON ON) (1-194) E (1-195

A current sensor abnormality has occurred. (01-195) Make sure that the electric actuator conforms to the controller. When a command to turn on servo is given, check if LK RLS is energized by installing the electric actuator vertically in order to check if the motor is driven by an external force.

A type mounting bracket B type mounting bracket Joint YA YB YU 56 67 83 100 18 22 28 36 6 8 10 12 55 100 195 340 YA-03 YA-05 YA-08 YA-10 32, 40 50, 63 80 100 Applicable mounting brackets Bore size (mm) Joint A type B type B type mounting brackets 32, 40 YU-03 YA-03 YB-03 50, 63 YU-05 YA-05 YB-05 80 YU-08 YA-08 YB-08 100 YU-10 YA-10 YB-10 Allowable eccentricity (mm) RS 32 40 50 63 80 100 Bore

CNS YA YB YU Type A mounting bracket YA-03 YA-05 YA-08 YA-10 6 18 56 55 Type B mounting bracket Joint 8 22 67 100 CLS 10 28 83 195 12 36 100 340 CLQ Applicable mounting bracket Bore size (mm) Joint Type A mounting bracket Type B mounting bracket RLQ Type B Mounting Bracket 32, 40 YU-03 YA-03 YB-03 MLU 50, 63 YU-05 YA-05 YB-05 80 YU-08 YA-08 YB-08 MLGP 100 YU-10 YA-10 YB-10 RS ML1C Allowable

Hose elbow (H) For nylon, soft nylon and polyurethane tubing 4/2.5 x R 4/2.5 x M5 LQ M-5HLH-4 M-01H-4 M-5P 1 8 P.199 MQR 6/4 x R 6/4 x M5 M-5HLH-6 P.198 M-01H-6 P.196 1 8 T Elbow One-sided 90 elbow M5 female x M5 female IDK M-5L P.198 195 M Series M3 Series Barb Fitting for Soft Tubing: M-3AU-3 Barb Fitting for Soft Tubing: M-3AU-4 Width across flats 5 Width across flats 5 M3 x 0.5 M3 x 0.5

PVC piping type, Applicable fluid:  deionized water, chemical, etc., Flow rate range:  10 to 100 L/min, Integrated type, 3-Color Digital Flow Siwtch for Water, DIGITAL FLOW SWITCH, WATER, PF3W, 195 lb

External Feedback Lever (IP5000 type) Stroke Order Code Unit Number Size M Size N P378010-11 150 125 10~85 mm (Nil) P378010-12 195 110 35~100 mm (E) P378010-13 275 110 50~140 mm (F) DIMENSIONAL DRAWINGS S E R I E S I P 5 0 0 0 / I P 5 1 0 0 IP5000 TYPE: LEVER TYPE LEVER FEEDBACK IP5100 TYPE: ROTARY TYPE CAM FEEDBACK IP5100 TYPE: NAMUR ADAPTER PLATE (Part Number: PAP5100-3) NAMUR MOUNTING

VM/VR Effective Area VH Port size 140 PA AR PA AR Rc(PT) Rc(PT) 3 4 Rc(PT)1 1 2 185 195 10.3 10.8 210 235 11.7 13.1 Effective area (mm2) 145 7.8 Cv factor 8.1 Precautions Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.