Spacer with Bracket: (Z) G F.R.L. body center C BB (Y100T, Y200T only) E 1 X-X EE (Y100T, Y200T only) RELEASE X B 2 E X A G Seal Y200T Y400T F J H K D Applicable models F 6.8 12 14 18 18 20 G 4.5 5.5 7 9 9 11 H 14 19 21 26 27 31 J 2.8 3.2 4 4 4.6 6.4 K 25 30 41 50 50 70 A 6 3 4 5 5 6 B 82 96 96 120 BB 56 67 C 24.5 29 41 48 48 60 D 40.5 53 68 81.5 86 112 E 20 24 35 40 40 50 EE 27 33 G 4.5
Rated voltage 100VAC, 50/60Hz 1 200VAC, 50/60Hz 2 110VAC, 50/60Hz 3 220VAC, 50/60Hz 4 24VDC 12VDC 5 Auto switch type 6 Nil Without auto switch (without built-in magnet) Solid state auto switches Switch quantity/Mounting position F9N F9P D-F9N D-F9P Symbol Quantity Mounting position Nil 2pcs. F9B D-F9B A Valve open/closed B C Note 1) The standard lead wire length is 0.5m.
) With dew point indicator 1 10/2.5 3 25/6 50/12 100/25 200/50 300/75 500/125 600/125 750/150 1000/190 5 S Standard equipment 10 20 30 50 60 75 100 Note) In case of two or more options, indicate them in alphabetical order.
Order the seal kit, based on each bore size. 8-29-5 6 Series CXS Construction: Ball Bushing Bearing CXSL6 y!6 @6 @3r !8 @4 !9 w !3 !0 @2 ut !5 !4 @0 !1 !2 e @1 q @7 @5 @8 CXSL10 CXSL15 @0 !5 @9 @4 r w !8 !9 !3 i !0 @2 u t !6 @0!5 @9@3@4 r!8w!9 !3 i!0 @2ut!
Material: Carbon steel 20 Series MU Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V B B A A Hs Hv D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A9 D-M9V D-M9WV D-M9AVL Size A B A B Hs Hv A B A B Hs Hv 25 5 5 5 5 7.5 27.5 1 1 1 1 32 5 5 5 5 14.5 30 1 1 1 1 40 5.5 5.5 5.5 5.5 16.5 37 1.5 1.5 1.5 1.5 50 7
C D B A 5 Standard Motor Series LJ1H10 Motor Output Slide Screw High Rigidity Direct Acting Guide 50W 20mm/20mm lead Horizontal Mount How to Order Stroke LJ1H101 SC 1 F 2 Cable entry direction Top entry Power supply voltage Cable entry direction Cable length Left entry 1 2 100/110VAC (50/60Hz) 200/220VAC (50/60Hz) F R L T B Axial Right Left Top Bottom 2 3 4 5 2m 3m 4m 5m Axial entry Right
(mm) B 88 98.5 19.5 22.5 78 88.5 A A B 69 78.5 CL CL 20 25 29.5 32.5 79 88.5 5 to 50 5 to 50 5 CU DCZ CX +0.4 +0.2 CW RR B + Stroke G L Bore size (mm) CL+ Stroke 0.1 0.3 CD CX CU CW CZ G L L1 RR S A + Stroke -X 20 25 8 10 12 14 18 20 8 10 16 20 27 31 4.5 5 18.5 22.5 9 10 39.2 43.2 Individual -X Rod end nut Refer to page 832 for details of rod end nuts and accessory brackets.
-L) 50 L/min 40 30 25 20 15 10 5 00 5 10 15 20 25 30 kPa Pressure loss [kPa] Pressure loss [kPa] 750 kPa 50 kPa 30 0 kPa 0 kPa 20 30 kPa 50 kPa 70 kPa 750 kPa 350 kPa 10 70 kPa 350 kPa 00 10 20 30 40 50 Flow [L/min] Flow [L/min] PF2M711(-L) 100 L/min PF2M721(-L) 200 L/min 40 90 80 70 60 50 40 30 20 10 00 50 100 150 200 Pressure loss [kPa] Pressure loss [kPa] 750 kPa 30 30 kPa 0 kPa 0 kPa
Operate with a load ratio of 50% or less. If the load ratio exceeds 50%, this may cause problems such as failure of the lock to release, or damage to the lock unit. 5.Do not operate multiple cylinders in synchronization.
Operate with a load ratio of 50% or less. If the load ratio exceeds 50%, this may cause problems such as failure of the lock to release, or damage to the lock unit. 5.Do not operate multiple cylinders in synchronization.
The parameter No.PC07 (home position return position data) setting value is the positioning address after the home position return is completed. 5 50 5.
N.C. 1 2 Note) 3 4 Note) 5 6 4-position dual 3-port valve (B) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC 2-position double Metal Rubber 4 2 B Note) 1 5 3 N.O.
5 u Parts list No. Description No.
F from 0.4MPa Graph 6 m from 0.5MPa Graph 7 F 31 Selection of Models Series MNB Selection Graphs Graph 5 Graph 2 0.3MPaP<0.4MPa 0.3MPaP<0.4MPa 1000 1000 500 400 300 500 400 300 100 80 200 200 63 100 80 100 50 40 100 100 Load weight: m(kg) Load weight: m(kg) 63 50 40 30 50 40 30 32 50 40 20 20 32 10 10 5 4 3 5 4 3 2 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Maximum speed: V(mm
Parts changed to stainless steel Symbol Part number Note Bore size (mm) 20, 25, 32, 40, 50 !9 is type L only. r!1!6!7!8!9@0@1@2@3@6@9#0#1#3#4#5#6#7 -XC6A 63, 80, 100 !7 is type L only, #1 is type B only, #9 and $0 are type F only. r!0!5!6!7!8!9@0@1@3@4@7@8@9#1#2#3#4#5#9$0 20, 25, 32, 40, 50 #1 is rod side only. r!1!7@0@1@2@3#1#5 -XC6B 63, 80, 100 @9 is rod side only. r!0!5!8!
water Set temperature range Note 1) 41 to 95F (5 to 35C) Cooling capacity 50/60 Hz Note 3) kW 9.0/9.5 13.0/14.5 Heating capacity 50/60 Hz Note 4) kW 1.7/2.2 2.5/3.0 Temperature stability Note 5) 1.8F (1.0C) Circulating uid system Rated ow 50/60 Hz (Outlet) Note 6) 11/14.8 gal/min (42/56 L/min) Maximum ow rate 50/60 Hz 14.5 to 17.9 gal/min (55/68 L/min) Maximum pump head 164 ft (50 m) Minimum
Nil W 2-5-5 Base Mounted 6 Series VQ4000 Plug-in Type Conduit terminal 2 position single: VQ410 0 1 23.5 23.5 50 158 50 90 108 158 Indicator light 11(12.5) 11(12.5) 5 3 2(B) port 4(A) port 9 4 2 38 48 10.5 1 11 A B 38 24.6 48 4 2 A 13.5 13.5 30 45 2-5.6 Mounting hole 14 5 1 3 12 30 45 2-5.6 Mounting hole 5-Rc 1/4, 3/8 (5(R1), 3(R2) port Rc 1/4) Manual override Courtesy of Steven Engineering
50 MHF 0 10 20 30 40 50 0 50 100 150 MHL Gripping point L (mm) Gripping point L (mm) MHZ2-16D/MHZL2-16D MHR MHZ2-40D 400 Pressure 0.7 MPa MHK Pressure 0.7 MPa 50 350 0.6 MPa 0.6 MPa 300 Gripping force (N) MHS 40 0.5 MPa 0.5 MPa 250 0.4 MPa 0.4 MPa 30 MHC 200 0.3 MPa 0.3 MPa 20 150 0.2 MPa MHT 0.2 MPa 100 10 50 MHY 0 10 20 30 40 50 60 0 50 100 150 200 MHW Gripping point L (mm) Gripping point