400 300 200 100 0 VF B VFR VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VZS C VFS VS4 800 700 600 500 400 300 200 100 0 VQ7 D EVS VFN 800 700 600 500 400 300 200 100 0 E It is when the cylinder is extending that is meter-out
Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ5140-01 Cylinder is in extending.
No.IP8S-OM09 45 (430) Operation setting*21 Set stroke for 0% and 100% of input signal by operating the actuator.
First find the ratio of the discharge rate for fresh water when viscosity is 100 mPas from the graph below. It is determined to be 45%. 2. Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 2.7 l/min.
0.10 to 0.68 0.10 to 0.49 Minimum operating flow rate*6 L/min 20 2 25 2 40 2 Tank capacity L 42 7 42 7 60 7 Bypass circuit (With valve) Installed Electric conductivity setting range S/cm 0.5 to 45*9 0.5 to 45 0.5 to 45*9 0.5 to 45 0.5 to 45*9 0.5 to 45 Circulating fluid system Pump capacity Particle filter nominal filtration rating (Accessory) m 5 5 5 5 5 5 Circulating fluid outlet, circulating
Models suitable to satisfy the requirement of 100 (N) are REA32 or REA40.
Bore size CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] Series 40 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQ4100--03 VQ4101--03 1100 1000 900 800 700 600 500 400 300 200 100 0 VQ5100--04 VQ5101--04 Values at extension
Bore size (mm) Max. stroke Standard stroke (mm) MB1 32 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 CP95 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 C95 63 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 80 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 C92 100 1900 25, 50, 80, 100, 125,
Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.
Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.
Bore size Cylinder stroke (mm) 12 16 20 25 32 40 50 63 80 100 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm Built-in Magnet Cylinder Model 12, 16 20, 25 32, 40 50 to 100 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 If a built-in magnet cylinder without an auto switch is
400 300 200 100 MY3A max.
, 60 RHC Mounting style 10 15, 30, 45, 60, 75, 100 16 15, 30, 45, 60, 75, 100 Basic style Foot style Rod side flange style Head side flange style (Except 6) Single clevis style (Non-integrated type) Double clevis style Note 1) Bore size: 20, 25 mm only Mounting brackets are shipped together, (but not assembled).
, 60 RHC Mounting style 10 15, 30, 45, 60, 75, 100 16 15, 30, 45, 60, 75, 100 Basic style Foot style Rod side flange style Head side flange style (Except 6) Single clevis style (Non-integrated type) Double clevis style Note 1) Bore size: 20, 25 mm only Mounting brackets are shipped together, (but not assembled).
105 110 D-Y7BA n 100 + 45 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 105 + 45 (n 4) 2 (n = 4, 8, 12, 16) Note 2) 110 + 45 (n 4) 2 (n = 4, 8, 12, 16) Note 2) (n = 2, 4, 6, 8) Note 1) 20 + 45 (n 2) 2 95 + 45 (n 4) 2 (n = 4, 8, 12, 16) Note 2) Note 1) When n is an odd number, an even number that is one larger than this odd number is used for the calculation.
, 60 6 Mounting 15, 30, 45, 60, 75, 100 10 15, 30, 45, 60, 75, 100 16 Standard type Foot type Front flange type Rear flange type (except 6) Single clevis type (non-integrated type) Double clevis type B L F G C Note) 15, 30, 45, 60, 75, 100 20 15, 30, 45, 60, 75, 100 25 Strokes are available in 1mm increments by installing spacers in standard stroke cylinders.
4/100 Find the dynamic moment Me (Nm).
No 3000G 45-089 Stripper for round cable (2.0) can be used for a 2-wire type cable. 181 Applicable auto switch list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6
Volume is reduced by up to approx. 45%.