SMC Corporation of America
Elite Part Number Search
Search Results "NCDME106-0800-A90L-XC6"

Magnet: None, Mounting: C (Single Clevis), Cushion: N (Urethane Cushion), Bore Size: 25mm, Stroke: 0800 (8"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Made to Order: XC6

Magnet: None, Mounting: U (Front Trunnion), Cushion: N (Urethane Cushion), Bore Size: 40mm, Stroke: 0800 (8"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: D (Built-in Magnet), Mounting: U (Front Trunnion), Cushion: N (Urethane Cushion), Bore Size: 32mm, Stroke: 0800 (8"), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: D (Built-in Magnet), Mounting: U (Front Trunnion), Cushion: N (Urethane Cushion), Bore Size: 32mm, Stroke: 0800 (8"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: D (Built-in Magnet), Mounting: U (Front Trunnion), Cushion: N (Urethane Cushion), Bore Size: 32mm, Stroke: 0800 (8"), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: Built-in Magnet, Mounting: Double End Mount, Bore: 1 1/16", Stroke: 8", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Environmental Options: Stainless Steel Rod

Magnet: Built-in Magnet, Mounting: Double End Mount, Bore: 1 1/16", Stroke: 8", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Environmental Options: Stainless Steel Rod

Magnet: Built-in Magnet, Mounting: Double End Mount, Bore: 1 1/16", Stroke: 8", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel Rod

Magnet: Built-in Magnet, Mounting: Double End Mount, Bore: 1 1/16", Stroke: 8", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel Rod

Magnet: Built-in Magnet, Mounting: Double End Mount, Bore: 1 1/16", Stroke: 8", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel Rod

Magnet: Built-in Magnet, Mounting: Double End Mount, Bore: 1 1/16", Stroke: 8", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Environmental Options: Stainless Steel Rod

Magnet: Built-in Magnet, Mounting: Double End Mount, Bore: 1 1/16", Stroke: 8", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel Rod

.-1060 Impact resistance-300m/s2 { 30.6G } Leak current-0 Protection rate-IEC529 standard IP67 (JIS0920) watertight When the lead wire length is 3m, the part number is suffixed with L. ex)D-A90L Solid state switch Lead wire-Oil resisting vinyl cap tire cord 2.7 0.15mm23 core (brown, black, blue)0.5m,18mm22 core(brown, blue)0.5m Insulation resistance-50M or more at DC500V (Between lead

(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: A90L--Reed, AC Volt, Horizontal, 3M

magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 1000mm, Option: Cushion at Both Ends, Cylinder Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: S (1 pc.), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: A90L

magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 500mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number: S (1 pc.), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: A90L

Example) D-A90L Contact protection box OUT () Brown [Red] Reed switch CD-P11 OUT () Blue [Black] CD-P12 Auto Switch Weights D-A93(V) (g) D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Type Brown [Red] Contact protection box OUT (+) Brown [Red] Resistor Lead wire length 0.5m 7 7 6 7 8 8 Reed switch Zener diode Lead wire length 3m 35 35 30 35 41 41 CD-P11 OUT () Blue [Black] CD-P12 Blue [Black]

Example) D-A90L Resistor DC power supply Load OUT Black [White] Reverse current prevention diode () DC () Blue [Black] Contact Protection Boxes/CD-P11, CD-P12 D-A9I and D-A9I type switches do not have internal contact protection circuits. 1. The operated load is an induction load. 2. The length of wiring to the load is 5m or more. 3. The load voltage is 100VAC.

Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A90L

Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A90L