Magnet: Built-in, Mounting: MX0, Basic, Bore Size: 2 1/2", Stroke: 24", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9BAV--Solid State, Water Resist., 2 Wire, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod
Magnet: Built-in, Mounting: MT4, Center trunnion, Bore Size: 4", Stroke: 24", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 24", Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: APC, Custom-made Specifications: Made of stainless steel
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 24", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 24", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 24", Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: APC, Custom-made Specifications: Made of stainless steel
0x097F (2431) 0x0980 (2432) 0x0981 (2433) 5 R/W Line name 5th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) 6 R/W Line name 6th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) 7 R/W Line name 7th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) 8 R/W Line name 8th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) Set the economy mode. 0: OFF 1: ON 0x0960 (2400
type type type Refrigerant R407C(HFC) Quantity of refrigerant kg 0.35 0.3 0.36 0.31 0.36 0.31 Control method PID control Ambient temperature and humidity2 Temperature: 5 to 40oC18 Humidity: 30 to 70% Circulating fluid3 Tap water, Ethylene glycol aqueous solution 15%5 Operating temperature oC 5 to 40 range2 Circulating fluid system Cooling capacity4 (50/60Hz) W 1100/1300 1700/1900 2100/2400
Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
OFF. 3 stop (2400 bps ~ 38400 bps) (9600 bps) Thermostat alarm Occurs when the thermostat that detects excessive heating begins operating. Temp.control Turn ON Main power switch again AL7 pump and fan Loosen the reservoir cap to help draining. (Do not remove the cap) stop 0.0 to 110.0 % 2.
To drain from the piping, blow air (0.05MPa, about 1 minute) from the 10.2 Troubleshooting 2.4 ~ 38.4 9.6 2 Integral Time (2400 bps ~ 38400 bps) (9600 bps) circulating fluid OUT to IN port. Close the reservoir cap while blowing. Code Cause Countermeasure setting Clean air filter periodically to avoid declining performance.
indication on display) Sets target temp. for control. 0.0 to 50.0C (0.1C) 25.0 1.0 to 60.0C (0.1C) 60.0 -9.99 to 9.99C (0.01C) 0.00 -9.9 to 49.0C (0.1C) -9.9 10 to 999% (1%) 200 0.0 to 10.0C (0.1C) 1.5 0.0 to 10.0C (0.1C) 1.5 2 PB Range Sets PB (Proportional Band) range used for PID control. 0.3 to 9.9C (0.1C) 3.0 0.0 to 99.9sec (0.1sec) 0.0 None, Odd, Even None On, Off Off 600, 1200, 2400
PA06 1 262144 (Position control mode) 2000 1200 600 2400 1600 800 3000 2000 1000 Electronic gear denominator *3.
Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
Baud Rate Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. B a u d R a t e M O D E < 1 2 0 0 b / s 3. Parity Bit Setting range : Without (no parity), Odd, Even Indicated content : Parity bit (Ex. : Without) Function : Sets parity bit for communication.
Temperature display) impair the performance. 600, 1200, 2400, Selects control operation mode from those shown below. 0: Pump stop (No control) 1: Normal operation 2: AT(auto tuning) 3: Learn (learning control) 4: External (external tune control) 5: SeriRem (Serial remote) 5:Serial remote is displayed when choose the Modbus communication. of the tank and the chassis near the tank could be
PA06 1 262144 (Position control mode) 2400 1600 800 3000 2000 1000 2700 4200 Electronic gear denominator *3.
Stop filling once the level of fluid reaches the H mark. 600, 1200, 2400, [AT]: Used to start auto tuning in auto tuning mode 5. Turn on the power switch to fill the piping with the fluid. 6.
SEL. key RS-232C Select the communication speed from 1200, 2400, 4800 ,9600 or 19200 with the UP/DOWN keys. Store the setting with the SET key. The SEL. key only shifts the cursor without storing the setting. The RS-232C communication speed setting mode is selected by pressing the SEL. key while RS232 is flashing. UP DOWN 3 -8 FUNC. FUNC. SEL. key Unit No.
FLANGE 3 150 174 R134a 890 3 3/4 PDE260-S 1007 7.5 8.5 23.6 78.7 55.1 19.7 19.7 460/3/60 FLANGE 3 150 174 R134a 990 5 PDE310-S 1200 7.8 8.8 23.6 78.7 55.1 19.7 19.7 460/3/60 FLANGE 3 150 174 R134a 1060 5 PDE410-S 1483 13.5 15.0 27.6 78.7 68.8 19.7 21.3 460/3/60 FLANGE 4 150 174 R134a 1180 6 PDE510-S 1840 15.5 17.8 27.6 78.7 68.8 19.7 21.3 460/3/60 FLANGE 4 150 174 R134a 1200 8.5 PDE610-S 2400