Bore Size: 8mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 12mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 16mm, Symmetric Type: Symmetric, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 8mm, Stroke: 20mm, Adjuster: Metal Stopper, Magnet: Magnet and Rail, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 8mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: Right Side, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
[Example of setting] Circulating fluid SP: 20C (1) High Temp. Circulating fluid temperature rise (AL10): 22C (2) Low Temp.
servo motor (100/200 VAC) Encoder Incremental 17-bit encoder (Resolution: 131072 p/rev) Horizontal 45 65 Power consumption [W] *5 Vertical 145 175 Horizontal 2 Standby power consumption when operating [W] *6 Vertical 8 Max. instantaneous power consumption [W] *7 445 724 Type *8 Non-magnetizing lock specifications Lock unit Holding force[N] 131 255 157 308 197 385 Power consumption [W] at 20C
degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig
Note2) Conditions that radiating water temperature is at 20C, radiating water flow rate is at 5 L/min, setting temperature is at 20C and ambient temperature is at 20C Note3) External sensor should be prepared by customers. Note4) Reservoir cap, Handle, Drip proof cover, connector are not included.
O.D. 1/8" 5/32" 5/32" 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 1/4" 5/16" 3/16" 1/4" 1/8" 5/32" Inch size 3/8" 5/16" 3/16" 1/4" Flow Direction Symbols on Body Meter-out type Meter-in type Flow rate (l/min (ANR)) Controlled flow (Free flow) 100 180 230 260 390 460 660 790 920 1580 1710 Symbol Effective area (mm2) 1.5 2.7 3.5 4 6 7 10 12 14 12 26 Note) Flow rate values are measured at 0.5 MPa and 20C
Symbol Proportional Solenoid Specifications Max. current 1A VEA250,VEA251 Applicable power amplifier 13W(20C, With maximum current) 13(20C) Coil resistance Rated power consumption Class H or equivalent (180C) Coil insulation 140C(With maximum current) Max. temperature rise DIN terminal Electrical entry Manifold Accessory Mounting screw (With washer) M5 X 45 VER2000 VER4000 Model AXT500-13
Burst pressure 25 20C to 60C Nylon 12 Min. bending radius (mm)(1) Operating temperature Material Note 1) The value at temp. of 20C and with O.D. variable rate 10% max.
Note 2) The data for l/min (ANR) refers to the conditions of 20C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of 30mA.
(mm) 4 6 8 10 12 3.18 4.76 6.35 9.53 12.7 2.5 4 5 6.5 8 2 3.18 4.23 6.35 8.46 Black (B) White (W) Red (R) Blue (BU) Burst Pressure Characteristics Curve Yellow (Y) Green (G) Clear (C) Orange (YR) Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Specifications Fluid Air, Water Max. operating pressure 0.8MPa at 20C Refer to pressure characteristics curve.
N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C (N) 31 Single acting type, normally closed 6 115 16 MHZ2-16C (N) 56 10 240 20 MHZ2-20C
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Item Conductor resistance /km, 20C Characteristics Cable length (L) Assmbly part no. Note Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Made to Order Specifications (For details, refer to page 3-6-11.)