SMC Corporation of America
Elite Part Number Search
Search Results "MWBL63TN-UT-750"

5 20 12 6 Stroke (mm) 500 500 500 600 700 800 600 700 800 600 700 800 Max. speed [mm/s] 500 250 1000 900 630 550 500 420 330 250 230 180 Min. speed [mm/s] (Independent and interpolation) 10 5 20 12 6 Min. speed [mm/s] (Speed tuning control) 17 9 33 20 10 Model LEFS32 Lead symbol H A B Lead [mm] 24 16 8 Stroke (mm) 600 700 800 900 1000 800 900 1000 800 900 1000 Max. speed [mm/s] 1200 930 750

ripple (p-p) 10% or below (with power supply polarity protection) Current consumption 48 mA or less (when no load is applied) Repeatability 1 2 0.1 mm (@25 oC) Resolution 0.05 mm Linearity 2 0.3 mm (@25 oC) Switch output NPN or PNP 1 output (push-pull) Max. load current 40 mA Internal voltage drop 2 V or less NPN: 0.5 mA or less at load resistance 3 k, 1.5 mA or less at load resistance 750

5 20 12 6 Stroke [mm] 500 500 500 600 700 800 600 700 800 600 700 800 Max. speed [mm/s] 500 250 1000 900 630 550 500 420 330 250 230 180 Min. speed [mm/s] (Independent and 10 5 20 12 6 interpolation) Min. speed [mm/s] 17 9 33 20 10 (Speed tuning control) Model LEFS32 Lead symbol H A B Lead [mm] 24 16 8 Stroke [mm] 600 700 800 900 1000 800 900 1000 800 900 1000 Max. speed [mm/s] 1200 930 750

EX120/121/122/124U/124D-SCS1 EX120/121/122/124U/124D-SCS2 Applicable system CompoBus/S Communication specifications Node address setting range 0 to 14 0 to 15 Communication speed 750 kbps Cable length Cable type Main cable length Branch cable length Total branch cable length When using VCTF cables 100 m or less 3 m or less 50 m or less When using special flat ribbon cable 30 m or less 3

point 32) Station type Remote device station Communication speed 156 Kbps 625 Kbps 2.5 Mbps 5 Mbps 10 Mbps Cable length between stations 20 cm and over Maximum extended cable length 1200 m 900 m 400 m 160 m 100 m Lower level bus Number of branches for input/output 4 branches for input, 4 branches for output Communication type Communication protocol: dedicated for SMC Communication speed: 750

500 kbps Thick cable 500 m or less 250 m or less 100 m or less Max. length of Network Thin cable 100m or less 156 m or less 78 m or less 39 m or less Total extended cable length : Max. extended cable length is 6 m Lower-level bus Number of branches for input/output 4 branches for input, 4 branches for output Communication type Communication protocol: dedicated for SMC Communication speed: 750

Lower-level bus Number of branches for input/output 4 branches for input, 4 branches for output Communication type Communication protocol: dedicated for SMC Communication speed: 750 kbps Current for input branch Max .1 A per branch Current for output branch Max. 1.5 A per branch Branch cable length Within 20 m (See diagram below for details.) : Maximum value in total of current consumption

(fluid: Dry air) Temperature characteristics 2%F.S. max. (15 to 35 C) 5%F.S. max. (0 to 15 C, 35 to 50 C) Pressure characteristics 5%F.S. max. (0.35 MPa reference) Rated pressure range -70 kPa to 750 kPa Proof pressure 1 MPa 50 msec. Response time (when "Select response time" wire (white) is connected to GND, response time is 1 sec.)

900,1000,1200,1500 Work load [kg] Note2) Horizontal 15 30 55 30 45 85 Vertical 3 5 10 6 10 20 Up to 500 1800 1200 600 1800 1200 600 501 to 600 1580 1050 520 1800 1200 600 601 to 700 1170 780 390 1800 1200 600 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110 740 370 Speed [mm/s] Note3) Stroke range 901 to 1000 580 390 190 900 600 300 Actuator specification 1001 to 1100 480 320 160 750

. -10 to +60o C with built-in magnet Ambient and fluid (No freezing) temperature Lubrication Not required (non-lube) +1.0 Stroke length tolerance 0 Cushion Rubber bumper Piston speed 50 to 750 mm/s 6 10 16 Allowable kinetic energy 0.012 J 0.035 J 0.090 J Use the actuator with allowable kinetic energy or less. Warning 1) Confirm the specifications.

ZFC1 ZFC3 ZFC5 ZFC7 5 20 L/min 750 mm 2 7 100 L/min 1260 mm 1 2 2 3.2 3 4 4 6 5 8 6 10 7 12 Inch size A 1/8 B 5/32 D 1/4 E 5/16 F 3/8 7 - 2-2 Specifications Specifications Remarks Fluid Air, Nitrogen This product cannot be used in an environment exposed to chemicals. The maximum operating pressure varies depending on the temperature.

1.5 M8 x 1.25 M18 x 1.5 12 14 15 11.5 M10 x 1.5 M22 x 1.5 M10 x 1.5 M26 x 1.5 17 With Rod Boot Note) ZZ indicates dimensions for double side rod boot. l h ZZ Note) Bore size (mm) e f 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 750

The maximum speed of 750 mm/s can be accommodated if the piston is to be locked in the stationary state for the purpose of drop prevention. CLQ MLGP Made to Order Specifications (For details, refer to page 9-16-1.)

Cylinder stroke (mm) Bore size (mm) Standard stroke (mm) Max. stroke with switch (mm) Max. stroke without switch (mm) 50, 100, 150, 200, 250, 300, 350 400, 450, 500 15 1000 750 20 25 32 1000 1200 1500 100, 150, 200, 250, 300, 350, 400 450, 500, 600, 700, 800 100, 150, 200, 250, 300, 350, 400 450, 500, 600, 700, 800, 900, 1000 2000 1500 40 Note 1) The longer the stroke, the larger the amount

HAA HAW AM Series Specifications AM150C AM250C Fluid Model Compressed air AT Max. operating pressure Rated flow (L/min (ANR)) 300 750 1.0 MPa Min. operating pressure Note) 0.05 MPa Port size (Nominal size B) 1/8, 1/4 1/4, 3/8 IDF IDU Proof pressure 1.5 MPa 5 to 60C Ambient temperature IDF FS 0.3 m (Filtering efficiency 99.9%) Nominal filtration rating Note) With auto drain: 0.1 MPa (N.O.

Standard Strokes Symbol Specifications X116 Hydro specifications X160 High speed specifications Note 1) Note 1) Max. stroke with switch (mm) Standard stroke (mm) Max. stroke without switch (mm) Bore size (mm) X168 Helical insert thread specifications X322 Outside of cylinder tube with hard chrome plating 50, 100, 150, 200, 250, 300 350, 400, 450, 500 XC57 With floating joint 15 750 1000 20

ASF JIS Symbol Flow Rate and Effective Area ASP330F ASP430F ASP530F ASP630F Model 10 12 8 8 10 Metric size 6, 8 6 1/4" 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Tubing O.D. 5/16" Inch size Flow rate (/min(ANR)) Controlled flow (Free flow) 180 600 750 1100 1190 330 350 Effective area (mm2) 9.3 11.6 17 18.4 2.9 5.2 5.4 Note) Flow rate values are measured at 0.5 MPa and 20C.

ASF JIS Symbol Flow Rate and Effective Area ASP330F ASP430F ASP530F ASP630F Model 10 12 8 8 10 Metric size 6, 8 6 1/4" 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Tubing O.D. 5/16" Inch size Flow rate (/min(ANR)) Controlled flow (Free flow) 180 600 750 1100 1190 330 350 Effective area (mm2) 9.3 11.6 17 18.4 2.9 5.2 5.4 Note) Flow rate values are measured at 0.5 MPa and 20C.

Model AM850 AM250 AM350 AM450 AM550 AM650 AM150 Rated flow (l/min (ANR)) 750 1500 2200 3500 6000 12000 300 (1) Port size (Nominal size B) 1/8 ,1/4 ,3/8 1/4 ,3/8 ,1/2 3/8 ,1/2 ,3/4 1/2 ,3/4 ,1 3/4 , 1 1, 11/2 11/2 , 2 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note 1) Max. flow capacity at a pressure of 0.7MPa. It varies depending on operating pressure.

Model AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 AMG150 (1) Flow rate (l /min (ANR)) 750 1500 2200 3500 6000 12000 300 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 3/4, 1 1, 11/2 11/2, 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow is at 0.7MPa. Max. flow depends on operating pressure.