Note 5) As for other commercial items, there are some cases it is not able to connect due to tolerance of dimensions. 2R Fixed side At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%.
Elbow Type (Metal body) Air Flow/Effective Area AS220M-02 AS120M AS220M-01 Model R 1/4 Cylinder side M5 x 0.8 10-32 UNF NPT 1/8 NPT 1/4 R 1/8 Port size Rc 1/4 Tube side Rc 1/8 Air flow (l/min (ANR)) 38 7 12 Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (l/min (ANR)) 420 105 280 REA Free flow Effective area (mm2) 6.5 1.6 4.3 Note) Supply pressure: 0.5 MPa, Temperature: 20C REB
9 Orange Black @0 Red White @1 Brown White Characteristics Item @2 Pink Red 65 or less Conductor resistance /km, 20C @3 Gray Red 1000 Withstand voltage VAC, 1 min. @4 Black White 5 or less Insulation resistance, Mkm, 20C @5 White None Note) Terminal no.@6 is connected to @5 inside the connector.
[ANR] Indicates the flow rate converted to a volume under standard conditions: 20C, 1 atm (atmosphere), 65%RH [Nl/min] Indicates the flow rate converted to a volume under normal conditions: 0C, 1 atm (atmosphere). External input Can be selected from accumulated value external reset, auto-shift and auto-shift zero.
DC Specification Temperature increase (C) Note) Power consumption (W) (Holding) 24 VDC 0.19 0.29 0.44 Inrush current (A) (Inrush time: 200 ms) Model 12 VDC 0.38 0.58 0.88 25 25 30 1.5 2.3 3 VXE21 VXE22 VXE23 Note) Value for ambient temperature at 20C and when the rated voltage is applied.
) Max. operating pressure (at 20C) 0.8MPa 1.5MPa Refer to series TU burst pressure characteristics curve.
MHK2-12D 12 4 9 13 75 Double acting Single acting MHK2-16D 16 6 14.6 20.6 113 MHK2-20D 20 10 16 26 235 MHZ MHK2-25D 25 14 19 33 440 MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed L1 MHF MHK2-16S 16 23 6 14.6 20.6 114 L2 L1 MHK2-20S 20 34 10 16 26 237 MHL L2 Series MHK2 MHK2-25S 25 58 14 19 33 443 Series MHKL2 MHK2-12C 12 12 4 9 13 76 MHR MHK2-16C 16 25 6 14.6 20.6 115 MHK MHK2-20C
46) I.D.holding :12.6 (56) MHK2-20D 20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S 20 7.6 (34) 10 16 26 8.4 L1 MHK2-25S 25 13.0 (58) 14 19 33 15.6 Single acting L2 MHK2-12C 12 2.7 (12) 4 9 13 2.7 MHK2-16C 16 5.6 (25) 6 14.6 20.6 4.1 MHK2-20C
3/16" 1/4" 3/16", 1/4" 5/16" Tube O.D. 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 38 Flow rate l/min (ANR) Controlled flow 0.2 0.1 0.6 Effective area mm Flow direction symbols on body 230 180 100 460 260 390 Flow rate l/min (ANR) Meter-out type Meter-in type Free flow 3.5 2.7 1.5 7 4 6 Effective area mm Note) The flow rate value is at a pressure of 0.5MPa and temperature of 20C
Inch sizes 1/4", 5/16" 3/16" 5/32" 3/16", 1/4" 1/8", 5/32", 3/16", 1/4" l/min (ANR) {Nl/min} Flow rate 12 38 7 Controlled flow Effective area mm 0.2 0.6 0.1 l/min (ANR) {Nl/min} Flow rate 460 100 290 130 230 Free flow Effective area mm 7 1.5 4.5 2 3.5 Note) Flow rates are values measured with pressure at 0.5MPa and temperature at 20C.
Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp.
Flow classification 11 The relation of the average free path of gas molecules and the pipe diameter D expressed as /D is the Knudsen number, and the relation of the pressure p(Torr) converted to air at 20C is expressed as pD.
Cool from 30C (303 K) to 20C (293 K). Circulating fluid : Tap water Density : 1 x 103 kg/m3 Specific heat C : 4.2 x 103 J/(kgK) Refer to the information shown below for the typical physical property values by circulating fluid. Water bath Q = T x V x x C h x 60 x 1000 10 x 2 x 1 x 103 x 4.2 x 103 20C V = 15 x 60 x 1000 After 15 min, = 93.3 W cool 30C down to 20C.
65 or less Gray 23 Red 1000 Withstand voltage VAC, 1 minute Black 24 White Insulation resistance Mkm, 20C 5 or less White 25 None Note) The minimum bending radius of each cable is 20 mm.
Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 minute, AC 1000 Cannot be used for transfer wiring.
Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232
. *5 Inlet pressure: 0.7 MPa Flow at 20C, atmospheric pressure, and 65% of the relative humidity 7 Compressed Air Preparation Filter AFF/AM/AMD Series Line Filter AFF Series Flow Rate Characteristics (Representative values) AFF/AM/AMD AMK Modular Connection Example Compressed air over the max. flow capacity line in the table below may not meet the specifications of the product.
/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 460 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.25 0.3 0.25 0.25 0.2 Free flow 0.2 0.3 0.2 0.3 0.4 Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C
3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow Free flow Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 1580 1710 460 920 Sonic Conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 Free flow 0.4 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at 0.5 MPa and 20C
MPa Min. operating pressure 5 to 60C (No freezing) Ambient and fluid temperature 20 turns 10 turns Number of needle rotation With seal Option 74 11.5 36 Weight (g) Flow rate (l/min (ANR)) 38 7 12 Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (l/min (ANR)) 420 105 280 Effective area (mm2) JIS Symbol Free flow 6.5 1.6 4.3 Note 1) Flow rate values are measured at 0.5 MPa and 20C