Do not drop, bump, or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 5. Do not allow short circuiting of loads.

V = 2gH/1000 x 60 Obtain the total amount of the work piece. Total mass m = 10 x 0.1 (kg) = 1 (kg) Obtain the intersection of the transfer speed V and the total weight of work piece m.

Do not drop, bump, or apply excessive impacts (1000 m/s2 or more while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause a malfunction. 2. Mount auto switches using the proper tightening torque.

Auto Switches Common Specifications Solid state auto switch Type Reed auto switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less Leakage current None Operating time 1 ms or less 1.2 ms Impact resistance 1000 m/s2 300 m/s2 50 M or more at 500 VDC Mega (Between lead wire and case) Insulation resistance 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (Between lead wire

m/s2 50 Mor more at 500 VDC Mega (between lead wire and case) Insulation resistance Withstand voltage 1000 VAC for 1 minute (between lead wire and case) 10 to 60C Ambient temperature Enclosure IEC60529 standard IP67 Standard CE marking Lead Wire Length Lead wire length indication L D-M9P (Example) Nil Lead wire length 0.5 m 1 m M 3 m L 5 m Z Note 1) Applicable auto switch with 5 m lead wire

[IS400-2 (Float switch only)] 1000 cm3 tank 121538-1A-S1 IS400-1 Metal bowl with level gauge 121538-1A-S2 IS400-2 Note) Bowl O-ring (or seal) is included for the AL20 to AL60.

In locations at altitude of 3000 m or higher (Except during storage and transportation) * For altitude of 1000 m or higher Because of lower air density, the heat radiation efficiencies of the devices in the product will be lower in the location at altitude of 1000 m or higher.

Lead wire length 2000 mm Nil 300 mm Changing the entry direction 6 600 mm 10 15 20 25 30 50 1000 mm After separating the terminal block and housing, the cord entry can be changed by attaching the housing in the desired direction (4 directions at 90 intervals).

Use only supplied cable and nut. 600 mm Maximum length for L-type 1000 mm 1500 mm 2000 mm 3000 mm 10 mm Semi-standard Warning Note) When placing an order for body ported solenoid valve as a single unit, mounting screws and gaskets for manifold are not included. Order them separately, if necessary. (For details, refer to page 18.)

Auto Switches Common Specifications Solid state auto switch Type Reed auto switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less Leakage current None Operating time 1 ms or less 1.2 ms Impact resistance 1000 m/s2 300 m/s2 50 M or more at 500 VDC Mega (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire

Tightening torque should be set 0.10 to 0.20 N.m. 11 Series C55 Auto Switch Specifications Auto Switch Common Specifications Reed switch Type Leakage current Solid state switch 3-wire: 100 A or less 2-wire: 0.8 mA or less None Operating time 1.2 ms 1 ms or less 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (between lead wire and case) Insulation resistance Withstand voltage

1 station 9 g Note) There was no malfunction confirmed when tested under the following conditions: From 10 to 500 to 10 Hz and whichever of the following is smaller: 1.5 mm amplitude or 98 m/s2 acceleration in X, Y, Z direction for 2 hours each.

Do not drop, bump or apply excessive impacts (300 m/s2 or more for reed auto switches and 1000 m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.

(Panel mounting) High-precision resolution: 1/1000 With analog output In addition to the conventional voltage output type (1 to 5 V) Current output type (4 to 20 mA) is now available.

DIN rail type, 40MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 9.03895 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation

(OUT1: Green, OUT2: Red) IP40 Operating: 0 to 50C, Stored: 10 to 60C (No freezing or condensation) Operating/Stored: 35 to 85% RH (No condensation) 1000 VAC for 1 minute between live parts and case 50 M or more between live parts and case (at 500 VDC Mega) 10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each 100 m/s2, in

DIN rail type, 40MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

DIN rail type, 40MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

DIN rail type, 40MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide

railtype, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 12.64901 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [kg] Note 2)Max. speed [mm/s]Max. acceleration/deceleration [mm/s2]Positioning repeatability [mm]Equivalent lead [mm]Impact/Vibration resistance [m/s2] Note 4)Actuation typeGuide