connector Ambient and fluid temperature (C) Maximum operating frequency (Hz) 10 3 Non-locking push type Push-turn locking slotted type Main and pilot valve common exhaust Pilot valve individual exhaust Not required Unrestricted 150/30 Dustproof Manual override (Manual operation) Internal pilot External pilot Pilot exhaust method Lubrication Mounting orientation Shock/Vibration resistance (m/s2
] 50 or less v Sulfuric acid ion (SO42) [mg/L] 50 or less v HRW Standard item dV dt HECR = Voltage increase ratio Acid consumption amount (at pH4.8) [mg/L] 50 or less v Total hardness [mg/L] 70 or less v Calcium hardness (CaCO3) [mg/L] 50 or less v Ionic state silica (SiO2) [mg/L] 30 or less v dV HEC Time HEB Iron (Fe) [mg/L] 0.3 or less v v Copper (Cu) [mg/L] 0.1 or less v Sulfide ion (S2
3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 30 A M5 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH090-ll-40 3-phase 380 to 415 VAC (50/60 Hz) 20 A Note) An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600
Impact acceleration [m/s2] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration 8-18-2 in vacuum environments (1.3 x 104 Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
VQC5000 Bore size MB, CA1 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm CS1 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Average speed [mm/s] 50 63 80 100 125 140 160 180 200 250 1100 Vertically upward Horizontal 1000 900 800 700 600 500 400 300 200 100 0 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open
S1 S2 PS P1 Indicator light Vacuum source Pressure sensor Z I SE1 2 Adjustment needle S3 S4 P2 ZSP Adsorption (0.3 to 1.2) ISA2 Internal Circuit and Wiring Example IS Lead wire colors inside ( ) are those prior to conformity to IEC standards.
W (N) 600 (1800) l 500 ML2B40 ML2B40 Caution (1500) If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting.
W (N) 600 (1800) l 500 ML2B40 ML2B40 Caution (1500) If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting.
] M2 M1 M3 m x g m x g Guide shaft mounting surface Guide central axis m x g Cylinder central axis Dynamic Moment Moment generated by the load equivalent to impact at the stroke end We: Load equivalent to impact [N] m : Load mass [kg] U: Max. speed [mm/s] g: Gravitational acceleration [9.8 m/s2] We = 5 x 103 x m x g x U Pich moment Me1 = 1/3 We (L + B) 103 Yaw moment Me3 = 1/3 We (L
the workpiece weight even when the cylinder is stopped Pitch moment M1 = m x g x (L + B) x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYV15 CYV32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m: Load mass [kg] L: Distance to load center of gravity [mm] A, B: Distance to guide shaft [mm] g: Gravitational acceleration [9.8 m/s2
rate: 50% Stroke 300 mm 6 10 16 20 25 32 40 Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ3140-M5 Cylinder is in extending.
(with connector and 2 of sockets only) Rated voltage Lead wire length 5 24 VDC Nil 300 mm 6 12 VDC 6 600 mm Electrical entry V 6 VDC 10 1000 mm Grommet, 300 mm lead wire G S 5 VDC 15 1500 mm Grommet, 600 mm lead wire H R 3 VDC 20 2000 mm L With lead wire 1 100 VAC 50/60 Hz L plug 25 2500 mm LN Without lead wire 2 200 VAC 50/60 Hz connector 30 3000 mm LO Without connector 110 VAC 50/60 Hz
Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series MB/CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series MB/CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ7140-02 Cylinder is in extending.
rate: 50% Stroke 300 mm 6 10 16 20 25 32 40 Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ3140-M5 Cylinder is in extending.
9 to 300 5 to 150 30 to 900 24 to 640 12 to 320 6 to 160 range 400 to 500 30 to 900 24 to 640 12 to 320 6 to 160 Actuator specification Max acceleration /deceleration [mm/s2] Horizontal 10 Vertical 5000 Pushing speed [mm/s2] Note5) 35 30 Positioning repeatability [mm] 0.05 Lost motion [mm] Note6) 0.1 or less Lead [mm] 20 12 6 3 24 16 8 4 Impact/Vibration resistance [m/s2] Note7) 50/20 Actuation
Mount switches in locations where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
Wall *1 For air-cooled type, leave a space of at least 600 mm between the heat exhausting surface and the wall. For water-cooled type, leave a space at least 600 mm between the facility water piping side and the wall. Leave at least 600 mm on the sides indicated with .
C 10 20 30 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-6 Cooling capacity *The Radiating water flow rate of 1L/min is for reference. Radiating water Temp.20 Ambient Temp.20 Fluid water 1000 Cooling capacity W 5 Radiating water flow rate L/min 800 1 3 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp.