Specifications Valve construction Rubber seal Fluid Air Maximum operating pressure 0.7 MPa Valve specifications Minimum operating pressure 0.2 MPa Ambient and fluid temperature 10 to 50C Note 1) Maximum operating cycle 5 Hz Pilot valve exhaust method Individual exhaust Pilot valve manual override Push type Lubrication Not required Impact/Vibration resistance Note 2) 30/100 m/s2 Enclosure
Not required Non-locking push type Not available Unrestricted 300/50 Dustproof Fluid Operating pressure range (MPa) Ambient and fluid temperature (C) Response time (ms) (at the pressure of 0.5 MPa) (1) Max. operating frequency (Hz) Effective area Lubrication Manual override Exhaust throttle Mounting orientation Shock/Vibration resistance (m/s2) (2) Enclosure Note 1) Based on dynamic performance
(packaged together) 50 80 650 F 40 550 G 10 300 H 4 200 J Filter (IN port) 100 Nil Without lter F With lter Note) Note) Flow reduction rate 50 L/min: 5% or less 100 L/min: 5 to 10% 150 L/min: 10 to 15% 80 600 K 40 500 L 10 250 M 4 150 150 Specications Flow rate (L/min) [at 0.25 MPa] 50 100 150 Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4 Type of actuation 2-position 2 port N.C.,
Refer to page 83.) 25 or less 40 or less 5 3 2 position single 2 position double 3 position Operating pressure range MPa Ambient and fluid temperature (C) Response time (ms) (at 0.5 MPa) Max. operating frequency (Hz) Manual override (Manual operation) Pilot exhaust method Lubrication Mounting orientation Shock/Vibration resistance (m/s2) Enclosure 2 position single, double 3 position 2 position
Impact/Vibration resistance m/s2 Note) 150/30 (8.3 to 2000Hz) Dust proof Enclosure Note) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.
Standard Strokes Bore size [mm] Standard stroke [mm] *1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 *1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.
Lowest limit OFF E C4SL-3 C1SL-3 C1SL-6 C1SL-36 C1SL-2 C1SL-23 C2SL-3 C2SL-C C2SL-3C C2SL-6 C2SL-36 C2SL-6C C2SL-36C C2SL-2 C2SL-23 C3SL-3 C3SL-3W C3SL-6 C3SL-36 C3SL-36W C3SL-2 C3SL-23 C3LL-8 C3LL-38 Polycarbonate AV C4SL-3W C4SL-6 C4SL-36 AF Nylon C4SL-36W C4SL-2 C4SL-23 C4LL-8 C4LL-38 Metal Metal bowl with level gauge 121538-1A 121538-1A-S1 [IS400-1 (Float switch only)] 121538-1A-S2
Pallet Lock Cylinder W-R1/W-R3 Series How to Order W R1 S2 Type 1 B W R3 S B Type 3 Proximity Switch B With mounting bracket (Without proximity switch) SC With proximity switch * For details, refer to the table below.
Vibration resistance allows for normal operation up to 30 m/s2 (45 to 250 Hz), but continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibrations or shocks. High temperature types (Models/XMH, XYH; Temperature specifications/H0) 1. When a valve is to be heated, only the body section should be heated, excluding the bonnet (handle) section.
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
Description Decimal Common Format "Data-INT" "Data-SINT" Input MIN. 1 word MIN. 2 byte MAX.250 words MAX.500 byte Output MIN. 1 word MIN. 2 byte MAX.248 words MAX.496 byte When configuration assembly fundtion is not used: Set to "0".
ID 0 1 2 1 063 1ABS() 3 1 ) 2INC() 4 H 2 065500 mm/s 5 L 6 3 7 2 4 2147483647 0.01mm 8 1 9 0 ID1 10 H 2 065500 mm/s2 11 L 12 H 2 065500 mm/s2 13 L 14 1 030 10% 15 1 030 10% 16 1 0255 mm/s 17 1 030 10% 18 H 2 065500 0.01mm 19 L ID2 2039 ID1 ID3 4059 ID1 ID4 6079 ID1 ID5 8099 ID1 ID6 100119 ID1 ID7 120139 ID1 ID8 140159 ID1 ) 0 12 36 - / Bit No.
Applying an excessive impact (more than 300 m/s2) may damage the product and cause malfunction. (2) Observe the proper tightening torque for mounting. If the screws are tightened in excessive of the specified torque range (0.2 to 0.4 Nm), it may damage the cylinder/actuator, mounting screws, mounting brackets, and sensor etc.
resistance Impact resistance 147 m/s2 is given 3 times for each direction X, Y and Z Operating environment No corrosive gas -12No.EX##-OMU0020-A 3.
Dual-Double Rod Type CXSW 39 Series CXS Auto Switch Common Specifications Auto Switch Common Specifications Type Solid state switch Reed switch Leakage current 3-wire: 100A or less; 2-wire: 0.8mA or less None Operating time 1ms or less 1.2ms Impact resistance 1000m/s2 300m/s2 Insulation resistance 50M or more at 500VDC (between lead wire and case) Withstand voltage 1500VAC for 1 min.
In addition, 3 of the wiring types are available with IP65 enclosures. 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ5100--04 VQ5101--04 IP65 compatible Enclosure Individual wiring type
Do not drop, bump, or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 5. Do not allow short circuiting of loads.